G-Star Pte Ltd GSD7S54T-420BT is a 420.0 W STC (399.2 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 21.65% efficiency, 39.41 V Voc at 25 C, and 42.51 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 420.0 W
- PTC Wattage
- 399.2 W
- Voc @ 25C
- 39.41 V
- Efficiency
- 21.65%
How Does G-Star Pte Ltd GSD7S54T-420BT Compare Against Peer CEC Listings?
Engineering position of G-Star Pte Ltd GSD7S54T-420BT (420.0 W STC) vs. AE Solar GmbH AE420CMD-108BDE across 5,889 CEC Mono-c-Si solar modules.
Ranking #7,910 across 21,677 CEC solar panels (top 37.8%; higher than 62.2% of peers), G-Star Pte Ltd GSD7S54T-420BT operates as a modern high-density residential and light-commercial module sitting 10.0 W above the 410.0 W Mono-c-Si median. Lower 39.41 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677), 20 panels occupy 418 sq ft and offset roughly $2,102/yr at average US rates (or $3,555/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does G-Star Pte Ltd GSD7S54T-420BT Fall Across Listed CEC Models?
Plots G-Star Pte Ltd GSD7S54T-420BT at 420.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define G-Star Pte Ltd GSD7S54T-420BT?
Benchmarks G-Star Pte Ltd GSD7S54T-420BT on STC wattage, thermal PTC/STC retention, and 21.65 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for G-Star Pte Ltd GSD7S54T-420BT?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for G-Star Pte Ltd GSD7S54T-420BT by G-Star Pte Ltd.
Top 37.8% STC Output
420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.65% Aperture Efficiency
Power density 216.5 W/m2 (1.74 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.51 V at -10 C (595.1 V string) and 43.4 V at -20 C (13 max).
20 Panels = 8,400 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,984 W PTC; NEC 690.8 OCPD floor is 20.94 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.41 * (1 + (-0.225/100) * (-10 - 25)) = 42.51 V | OCPD = 1.56 * 13.42 = 20.94 A
Inputs from CEC Modules.csv for G-Star Pte Ltd GSD7S54T-420BT: Voc=39.41 V, beta_Voc=-0.225%/C, Isc=13.42 A, STC=420.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (595.1 V); 20 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for G-Star Pte Ltd GSD7S54T-420BT?
Laboratory test ratings recorded for G-Star Pte Ltd GSD7S54T-420BT (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 399.2 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.41 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.42 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.72 V / 12.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.225 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.65% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many G-Star Pte Ltd GSD7S54T-420BT Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (418 sq ft at 8 kW), and estimated Year-1 electric bill offset for G-Star Pte Ltd GSD7S54T-420BT.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.3 kW | 313 sq ft | $1,577 | $2,666 |
| 8 kW Class | 20 | 8.4 kW | 418 sq ft | $2,102 | $3,555 |
| 10 kW Class | 24 | 10.08 kW | 501 sq ft | $2,523 | $4,266 |
How Many G-Star Pte Ltd GSD7S54T-420BT Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for G-Star Pte Ltd GSD7S54T-420BT (beta_Voc -0.225%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.4 V | 13 panels | 564.2 V | 23 panels |
| -10 C (14 F) | 42.51 V | 14 panels | 595.1 V | 23 panels |
| 0 C (32 F) | 41.63 V | 14 panels | 582.8 V | 24 panels |
| 25 C (77 F STC) | 39.41 V | 15 panels | 591.1 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to G-Star Pte Ltd GSD7S54T-420BT?
Closest cross-brand CEC competitors to G-Star Pte Ltd GSD7S54T-420BT matched near 420.0 W STC and 39.41 V Voc, led by AE Solar GmbH AE420CMD-108BDE.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AE Solar GmbH AE420CMD-108BDE AE Solar GmbH |
420.0 W | Tie (0 W) | 39.7 V | 21.54% | 94.8% |
| DE SOLAR(S) PTE LTD DE420-108BG-182S-N/BB DE SOLAR(S) PTE LTD |
420.0 W | Tie (0 W) | 39.7 V | 21.54% | 94.8% |
| Aptos Solar Technology LLC DNA-108-MFN10-420W Aptos Solar Technology LLC |
420.0 W | Tie (0 W) | 38.5 V | 21.65% | 95.0% |
| Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-420 Elin Energy (Sirius PV) |
420.0 W | Tie (0 W) | 38.5 V | 21.65% | 94.9% |
What Are the Design Limits and Best-Fit Uses for G-Star Pte Ltd GSD7S54T-420BT?
Evaluate G-Star Pte Ltd GSD7S54T-420BT (420.0 W STC, 39.41 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), G-Star Pte Ltd GSD7S54T-420BT reaches 43.4 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of G-Star Pte Ltd GSD7S54T-420BT carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
G-Star Pte Ltd GSD7S54T-420BT 8 kW Residential Fit
Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AE Solar GmbH AE420CMD-108BDE.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 399.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for G-Star Pte Ltd GSD7S54T-420BT by G-Star Pte Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many G-Star Pte Ltd GSD7S54T-420BT panels fit on a 600 V winter solar string?
At -10 C (14 F), G-Star Pte Ltd GSD7S54T-420BT cold Voc rises from 39.41 V to 42.51 V (beta_Voc -0.225%/C), capping a 600 V string at 14 panels (595.1 V).
How much roof area does an 8 kW array of G-Star Pte Ltd GSD7S54T-420BT need?
An 8 kW DC system uses 20 G-Star Pte Ltd GSD7S54T-420BT modules (8,400 W STC / 7,984 W PTC), covering roughly 418 sq ft and saving ~$2,102/yr at 18.54 c/kWh.
How does G-Star Pte Ltd GSD7S54T-420BT compare against AE Solar GmbH AE420CMD-108BDE?
G-Star Pte Ltd GSD7S54T-420BT outputs 420.0 W STC (39.41 V Voc, rank #7,910 of 21,677), while AE Solar GmbH AE420CMD-108BDE delivers 420.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)