G-Star Pte Ltd GSP6G60M(H)380BT is a 380.0 W STC (358.6 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.99% efficiency, 41.5 V Voc at 25 C, and 45.84 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 358.6 W
- Voc @ 25C
- 41.5 V
- Efficiency
- 20.99%
How Does G-Star Pte Ltd GSP6G60M(H)380BT Compare Against Peer CEC Listings?
Solar engineering breakdown for G-Star Pte Ltd GSP6G60M(H)380BT: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from G-Star Pte Ltd and peers, G-Star Pte Ltd GSP6G60M(H)380BT stands 30.0 W below the 410.0 W Mono-c-Si median and strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,522-$2,568/yr in baseline US bill offset. Mid-range 41.5 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does G-Star Pte Ltd GSP6G60M(H)380BT Fall Across Listed CEC Models?
Distribution marker showing G-Star Pte Ltd GSP6G60M(H)380BT (380.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define G-Star Pte Ltd GSP6G60M(H)380BT?
Dataset percentiles tracking G-Star Pte Ltd GSP6G60M(H)380BT power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for G-Star Pte Ltd GSP6G60M(H)380BT?
Benchmark highlights for G-Star Pte Ltd GSP6G60M(H)380BT covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.99% Aperture Efficiency
Power density 209.9 W/m2 (1.08 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.84 V at -10 C (595.9 V string) and 47.08 V at -20 C (12 max).
22 Panels = 8,360 W STC
Occupies 39.8 m2 (429 sq ft) producing 7,889 W PTC; NEC 690.8 OCPD floor is 17.74 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.5 * (1 + (-0.299/100) * (-10 - 25)) = 45.84 V | OCPD = 1.56 * 11.37 = 17.74 A
Inputs from CEC Modules.csv for G-Star Pte Ltd GSP6G60M(H)380BT: Voc=41.5 V, beta_Voc=-0.299%/C, Isc=11.37 A, STC=380.0 W, Area=1.81 m2.
Result: 13 panels max on 600 V (595.9 V); 22 panels for 8 kW (429 sq ft).
What Are the Published CEC Specifications for G-Star Pte Ltd GSP6G60M(H)380BT?
Official CEC datasheet figures for G-Star Pte Ltd GSP6G60M(H)380BT (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 358.6 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.5 V / 10.71 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.299 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.99% (1.81 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many G-Star Pte Ltd GSP6G60M(H)380BT Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many G-Star Pte Ltd GSP6G60M(H)380BT modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 312 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 429 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 526 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This G-Star Pte Ltd Series?
Consolidated G-Star Pte Ltd wattage variants sharing the G-Star Pte Ltd GSP6G60M(H)380BT mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| G-Star Pte Ltd GSP6G60M(H)375BT | 375.0 W | 353.7 W | 41.3 V | 35.2 V | 20.72% |
| G-Star Pte Ltd GSP6G60M(H)380BT | 380.0 W | 358.6 W | 41.5 V | 35.5 V | 20.99% |
| G-Star Pte Ltd GSP6G60M(H)385BT | 385.0 W | 363.4 W | 41.7 V | 35.8 V | 21.27% |
How Many G-Star Pte Ltd GSP6G60M(H)380BT Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on G-Star Pte Ltd GSP6G60M(H)380BT (45.84 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 47.08 V | 12 panels | 565.0 V | 21 panels |
| -10 C (14 F) | 45.84 V | 13 panels | 595.9 V | 21 panels |
| 0 C (32 F) | 44.6 V | 13 panels | 579.8 V | 22 panels |
| 25 C (77 F STC) | 41.5 V | 14 panels | 581.0 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to G-Star Pte Ltd GSP6G60M(H)380BT?
Competing CEC solar panels closest to G-Star Pte Ltd GSP6G60M(H)380BT in nameplate wattage and Voc, starting with DualSun SAS DualSun 380M-120-01.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DualSun SAS DualSun 380M-120-01 DualSun SAS |
380.0 W | Tie (0 W) | 41.3 V | 21.47% | 93.9% |
| Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC Boviet Solar Technology Co Ltd |
380.0 W | Tie (0 W) | 40.94 V | 20.54% | 94.2% |
| CSI Solar Co Ltd CS3L-385MS CSI Solar Co Ltd |
385.0 W | +5.0 W | 41.4 V | 21.51% | 93.2% |
| CSI Solar Co Ltd CS3L-375P CSI Solar Co Ltd |
375.0 W | -5.0 W | 41.2 V | 20.95% | 92.5% |
What Are the Design Limits and Best-Fit Uses for G-Star Pte Ltd GSP6G60M(H)380BT?
Evaluate G-Star Pte Ltd GSP6G60M(H)380BT (380.0 W STC, 41.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), G-Star Pte Ltd GSP6G60M(H)380BT reaches 47.08 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
- 2026 tax credit baseline: cash residential installs of G-Star Pte Ltd GSP6G60M(H)380BT carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
G-Star Pte Ltd GSP6G60M(H)380BT 8 kW Residential Fit
Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare DualSun SAS DualSun 380M-120-01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 358.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for G-Star Pte Ltd GSP6G60M(H)380BT by G-Star Pte Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for G-Star Pte Ltd GSP6G60M(H)380BT?
Multiplying G-Star Pte Ltd GSP6G60M(H)380BT's 11.37 A short-circuit current by 1.56 equals 17.74 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can G-Star Pte Ltd GSP6G60M(H)380BT pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.84 V cold Voc at 14 F and handles 11.37 A Isc; string inverters cap G-Star Pte Ltd GSP6G60M(H)380BT at 13 panels on 600 V.
Is G-Star Pte Ltd GSP6G60M(H)380BT eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of G-Star Pte Ltd GSP6G60M(H)380BT rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)