G-Star Pte Ltd GSD7G78M-605BT is a 605.0 W STC (570.9 W PTC) Mono-c-Si solar module ranking #1,214 of 21,677 CEC listings (top 6.1%; higher than 93.9% of peers). It delivers 21.84% efficiency, 54.29 V Voc at 25 C, and 59.91 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 605.0 W
- PTC Wattage
- 570.9 W
- Voc @ 25C
- 54.29 V
- Efficiency
- 21.84%
How Does G-Star Pte Ltd GSD7G78M-605BT Compare Against Peer CEC Listings?
Engineering position of G-Star Pte Ltd GSD7G78M-605BT (605.0 W STC) vs. KOSOL ENERGIE PVT LTD KE605T across 5,889 CEC Mono-c-Si solar modules.
Ranking #1,214 across 21,677 CEC solar panels (top 6.1%; higher than 93.9% of peers), G-Star Pte Ltd GSD7G78M-605BT operates as a large-format commercial and ground-mount module sitting 195.0 W above the 410.0 W Mono-c-Si median. Higher 54.29 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677), 14 panels occupy 417 sq ft and offset roughly $2,120/yr at average US rates (or $3,585/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does G-Star Pte Ltd GSD7G78M-605BT Fall Across Listed CEC Models?
Plots G-Star Pte Ltd GSD7G78M-605BT at 605.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define G-Star Pte Ltd GSD7G78M-605BT?
Benchmarks G-Star Pte Ltd GSD7G78M-605BT on STC wattage, thermal PTC/STC retention, and 21.84 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for G-Star Pte Ltd GSD7G78M-605BT?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for G-Star Pte Ltd GSD7G78M-605BT by G-Star Pte Ltd.
Top 6.1% STC Output
605.0 W STC (+220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.84% Aperture Efficiency
Power density 218.4 W/m2 (1.93 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 59.91 V at -10 C (599.1 V string) and 61.52 V at -20 C (9 max).
14 Panels = 8,470 W STC
Occupies 38.8 m2 (417 sq ft) producing 7,993 W PTC; NEC 690.8 OCPD floor is 22.06 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 54.29 * (1 + (-0.296/100) * (-10 - 25)) = 59.91 V | OCPD = 1.56 * 14.14 = 22.06 A
Inputs from CEC Modules.csv for G-Star Pte Ltd GSD7G78M-605BT: Voc=54.29 V, beta_Voc=-0.296%/C, Isc=14.14 A, STC=605.0 W, Area=2.77 m2.
Result: 10 panels max on 600 V (599.1 V); 14 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for G-Star Pte Ltd GSD7G78M-605BT?
Laboratory test ratings recorded for G-Star Pte Ltd GSD7G78M-605BT (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 605.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 570.9 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 54.29 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.14 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.67 V / 13.25 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.296 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.84% (2.77 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many G-Star Pte Ltd GSD7G78M-605BT Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (417 sq ft at 8 kW), and estimated Year-1 electric bill offset for G-Star Pte Ltd GSD7G78M-605BT.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.05 kW | 298 sq ft | $1,514 | $2,561 |
| 8 kW Class | 14 | 8.47 kW | 417 sq ft | $2,120 | $3,585 |
| 10 kW Class | 17 | 10.29 kW | 507 sq ft | $2,575 | $4,355 |
Which Sibling Wattage & Trim Variants Belong to This G-Star Pte Ltd Series?
Sibling wattage bins and frame colors grouped with G-Star Pte Ltd GSD7G78M-605BT under G-Star Pte Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| G-Star Pte Ltd GSD7G78M-600BT | 600.0 W | 566.1 W | 54.15 V | 45.53 V | 21.66% |
| G-Star Pte Ltd GSD7G78M-605BT | 605.0 W | 570.9 W | 54.29 V | 45.67 V | 21.84% |
| G-Star Pte Ltd GSD7G78M-610BT | 610.0 W | 575.8 W | 54.43 V | 45.81 V | 22.02% |
How Many G-Star Pte Ltd GSD7G78M-605BT Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for G-Star Pte Ltd GSD7G78M-605BT (beta_Voc -0.296%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 61.52 V | 9 panels | 553.7 V | 16 panels |
| -10 C (14 F) | 59.91 V | 10 panels | 599.1 V | 16 panels |
| 0 C (32 F) | 58.31 V | 10 panels | 583.1 V | 17 panels |
| 25 C (77 F STC) | 54.29 V | 11 panels | 597.2 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to G-Star Pte Ltd GSD7G78M-605BT?
Closest cross-brand CEC competitors to G-Star Pte Ltd GSD7G78M-605BT matched near 605.0 W STC and 54.29 V Voc, led by KOSOL ENERGIE PVT LTD KE605T.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| KOSOL ENERGIE PVT LTD KE605T KOSOL ENERGIE PVT LTD |
605.0 W | Tie (0 W) | 54.3 V | 21.84% | 94.4% |
| Boviet Solar Technology Co Ltd BVM7613M-605-H-HC Boviet Solar Technology Co Ltd |
605.0 W | Tie (0 W) | 54.4 V | 21.61% | 94.4% |
| GermanSolar USA Inc GSM10-144-605W GermanSolar USA Inc |
605.0 W | Tie (0 W) | 54.89 V | 25.1% | 95.2% |
| KOSOL ENERGIE PVT LTD KE605N KOSOL ENERGIE PVT LTD |
605.0 W | Tie (0 W) | 53.6 V | 23.63% | 95.2% |
What Are the Design Limits and Best-Fit Uses for G-Star Pte Ltd GSD7G78M-605BT?
Evaluate G-Star Pte Ltd GSD7G78M-605BT (605.0 W STC, 54.29 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), G-Star Pte Ltd GSD7G78M-605BT reaches 61.52 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of G-Star Pte Ltd GSD7G78M-605BT carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
G-Star Pte Ltd GSD7G78M-605BT 8 kW Residential Fit
Needs 14 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,120/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 9 panels (-20 C), or compare KOSOL ENERGIE PVT LTD KE605T.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 570.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for G-Star Pte Ltd GSD7G78M-605BT by G-Star Pte Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many G-Star Pte Ltd GSD7G78M-605BT panels fit on a 600 V winter solar string?
At -10 C (14 F), G-Star Pte Ltd GSD7G78M-605BT cold Voc rises from 54.29 V to 59.91 V (beta_Voc -0.296%/C), capping a 600 V string at 10 panels (599.1 V).
How much roof area does an 8 kW array of G-Star Pte Ltd GSD7G78M-605BT need?
An 8 kW DC system uses 14 G-Star Pte Ltd GSD7G78M-605BT modules (8,470 W STC / 7,993 W PTC), covering roughly 417 sq ft and saving ~$2,120/yr at 18.54 c/kWh.
How does G-Star Pte Ltd GSD7G78M-605BT compare against KOSOL ENERGIE PVT LTD KE605T?
G-Star Pte Ltd GSD7G78M-605BT outputs 605.0 W STC (54.29 V Voc, rank #1,214 of 21,677), while KOSOL ENERGIE PVT LTD KE605T delivers 605.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)