G-Star Pte Ltd GSP7F54M(H)410BB is a 410.0 W STC (386.2 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 37.5 V Voc at 25 C, and 40.95 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 386.2 W
- Voc @ 25C
- 37.5 V
- Efficiency
- 21.03%
How Does G-Star Pte Ltd GSP7F54M(H)410BB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for G-Star Pte Ltd GSP7F54M(H)410BB (Mono-c-Si) residential solar systems.
Homeowners evaluating G-Star Pte Ltd GSP7F54M(H)410BB need 15 panels for 6 kW or 20 panels (420 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.263%/C) pushes open-circuit voltage to 40.95 V at 14 F and 41.94 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does G-Star Pte Ltd GSP7F54M(H)410BB Fall Across Listed CEC Models?
Comparison of G-Star Pte Ltd GSP7F54M(H)410BB (410.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define G-Star Pte Ltd GSP7F54M(H)410BB?
Relative ranking of G-Star Pte Ltd GSP7F54M(H)410BB across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for G-Star Pte Ltd GSP7F54M(H)410BB?
Summary of G-Star Pte Ltd GSP7F54M(H)410BB output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.03% Aperture Efficiency
Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.95 V at -10 C (573.3 V string) and 41.94 V at -20 C (14 max).
20 Panels = 8,200 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,724 W PTC; NEC 690.8 OCPD floor is 21.75 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.5 * (1 + (-0.263/100) * (-10 - 25)) = 40.95 V | OCPD = 1.56 * 13.94 = 21.75 A
Inputs from CEC Modules.csv for G-Star Pte Ltd GSP7F54M(H)410BB: Voc=37.5 V, beta_Voc=-0.263%/C, Isc=13.94 A, STC=410.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (573.3 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for G-Star Pte Ltd GSP7F54M(H)410BB?
Complete CEC test sheet for G-Star Pte Ltd GSP7F54M(H)410BB including Isc (13.94 A), Voc (37.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 386.2 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.94 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.43 V / 13.05 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.03% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many G-Star Pte Ltd GSP7F54M(H)410BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using G-Star Pte Ltd GSP7F54M(H)410BB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 315 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 420 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 525 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This G-Star Pte Ltd Series?
Related G-Star Pte Ltd power steps and black/silver trims consolidated into this G-Star Pte Ltd GSP7F54M(H)410BB series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| G-Star Pte Ltd GSP7F54M(H)400BB | 400.0 W | 376.6 W | 37.0 V | 31.05 V | 20.51% |
| G-Star Pte Ltd GSP7F54M(H)405BB | 405.0 W | 381.4 W | 37.25 V | 31.24 V | 20.77% |
| G-Star Pte Ltd GSP7F54M(H)410BB | 410.0 W | 386.2 W | 37.5 V | 31.43 V | 21.03% |
| G-Star Pte Ltd GSP7F54M(H)415BB | 415.0 W | 391.1 W | 37.75 V | 31.64 V | 21.28% |
How Many G-Star Pte Ltd GSP7F54M(H)410BB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for G-Star Pte Ltd GSP7F54M(H)410BB (37.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.94 V | 14 panels | 587.2 V | 23 panels |
| -10 C (14 F) | 40.95 V | 14 panels | 573.3 V | 24 panels |
| 0 C (32 F) | 39.97 V | 15 panels | 599.5 V | 25 panels |
| 25 C (77 F STC) | 37.5 V | 16 panels | 600.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to G-Star Pte Ltd GSP7F54M(H)410BB?
Four comparable CEC modules such as Bluesun Solar CoLtd BSM410M10-54HPH (410.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar CoLtd BSM410M10-54HPH Bluesun Solar CoLtd |
410.0 W | Tie (0 W) | 37.5 V | 20.99% | 93.3% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
410.0 W | Tie (0 W) | 37.51 V | 21.58% | 94.5% |
| Auxin Solar AXN10M410B Auxin Solar |
410.0 W | Tie (0 W) | 37.54 V | 21.64% | 94.0% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154B 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | Tie (0 W) | 37.34 V | 21.24% | 92.2% |
What Are the Design Limits and Best-Fit Uses for G-Star Pte Ltd GSP7F54M(H)410BB?
Evaluate G-Star Pte Ltd GSP7F54M(H)410BB (410.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), G-Star Pte Ltd GSP7F54M(H)410BB reaches 41.94 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of G-Star Pte Ltd GSP7F54M(H)410BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
G-Star Pte Ltd GSP7F54M(H)410BB 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Bluesun Solar CoLtd BSM410M10-54HPH.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 386.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for G-Star Pte Ltd GSP7F54M(H)410BB by G-Star Pte Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is G-Star Pte Ltd GSP7F54M(H)410BB PTC wattage (386.2 W) lower than STC (410.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 386.2 W PTC (94.2% retention) across G-Star Pte Ltd GSP7F54M(H)410BB's 1.95 m2 aperture.
Who should skip G-Star Pte Ltd GSP7F54M(H)410BB on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 G-Star Pte Ltd GSP7F54M(H)410BB panels (420 sq ft) leave unusable roof gaps vs. Bluesun Solar CoLtd BSM410M10-54HPH.
What is the 1,000 V commercial string limit for G-Star Pte Ltd GSP7F54M(H)410BB?
On 1,000 V commercial inverters at -10 C (40.95 V cold Voc), G-Star Pte Ltd GSP7F54M(H)410BB fits up to 24 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)