Auxin Solar AXN10M410B — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN10M410B is a 410.0 W STC (385.5 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.64% efficiency, 37.54 V Voc at 25 C, and 40.75 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
385.5 W
Voc @ 25C
37.54 V
Efficiency
21.64%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN10M410B Compare Against Peer CEC Listings?

Engineering position of Auxin Solar AXN10M410B (410.0 W STC) vs. DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M across 5,889 CEC Mono-c-Si solar modules.

Built with 54 Mono-c-Si cells, Auxin Solar AXN10M410B pairs strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677) with 37.54 V nominal Voc. An 8 kW residential build (8,200 W DC, 7,710 W PTC) saves ~$2,052/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M offers a 410.0 W alternative.

Where Does Auxin Solar AXN10M410B Fall Across Listed CEC Models?

Plots Auxin Solar AXN10M410B at 410.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN10M410B (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN10M: 410.0 W

What Dataset Percentiles Define Auxin Solar AXN10M410B?

Benchmarks Auxin Solar AXN10M410B on STC wattage, thermal PTC/STC retention, and 21.64 aperture conversion efficiency against CEC peers.

Auxin Solar AXN10M410B Engineering BenchmarksPercentile comparison of Auxin Solar AXN10M410B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention94.0%Module Efficiency21.64%

What Do the Dataset Ranks Show for Auxin Solar AXN10M410B?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN10M410B by Auxin Solar.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,074

21.64% Aperture Efficiency

Power density 216.4 W/m2 (1.73 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.75 V at -10 C (570.5 V string) and 41.66 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 37.9 m2 (408 sq ft) producing 7,710 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.54 * (1 + (-0.244/100) * (-10 - 25)) = 40.75 V | OCPD = 1.56 * 13.86 = 21.62 A

Inputs from CEC Modules.csv for Auxin Solar AXN10M410B: Voc=37.54 V, beta_Voc=-0.244%/C, Isc=13.86 A, STC=410.0 W, Area=1.895 m2.

Result: 14 panels max on 600 V (570.5 V); 20 panels for 8 kW (408 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN10M410B?

Laboratory test ratings recorded for Auxin Solar AXN10M410B (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN10M410B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 385.5 W (94.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.54 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.86 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.55 V / 13.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.244 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.64% (1.895 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Auxin Solar AXN10M410B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (408 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN10M410B.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 306 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 408 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 510 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

Sibling wattage bins and frame colors grouped with Auxin Solar AXN10M410B under Auxin Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Auxin Solar AXN10M410B wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN10M400B 400.0 W 375.9 W 37.2 V 31.17 V 21.11%
Auxin Solar AXN10M405B 405.0 W 380.7 W 37.36 V 31.36 V 21.37%
Auxin Solar AXN10M410B 410.0 W 385.5 W 37.54 V 31.55 V 21.64%
Auxin Solar AXN10M415B 415.0 W 386.4 W 38.04 V 32.18 V 21.39%
Auxin Solar AXN10M420B 420.0 W 391.2 W 38.26 V 32.62 V 21.65%

How Many Auxin Solar AXN10M410B Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Auxin Solar AXN10M410B (beta_Voc -0.244%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.54V and beta_Voc=-0.244%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.66 V 14 panels 583.2 V 24 panels
-10 C (14 F) 40.75 V 14 panels 570.5 V 24 panels
0 C (32 F) 39.83 V 15 panels 597.4 V 25 panels
25 C (77 F STC) 37.54 V 15 panels 563.1 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN10M410B?

Closest cross-brand CEC competitors to Auxin Solar AXN10M410B matched near 410.0 W STC and 37.54 V Voc, led by DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
410.0 W Tie (0 W) 37.51 V 21.58% 94.5%
Bluesun Solar CoLtd BSM410M10-54HPH
Bluesun Solar CoLtd
410.0 W Tie (0 W) 37.5 V 20.99% 93.3%
Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1
Aptos Solar Technology LLC
410.0 W Tie (0 W) 37.7 V 21.13% 94.3%
Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos2
Aptos Solar Technology LLC
410.0 W Tie (0 W) 37.7 V 21.13% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN10M410B?

Evaluate Auxin Solar AXN10M410B (410.0 W STC, 37.54 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN10M410B reaches 41.66 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 408 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (408 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN10M410B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN10M410B 8 kW Residential Fit

Needs 20 modules (408 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 385.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN10M410B by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Auxin Solar AXN10M410B?

Multiplying Auxin Solar AXN10M410B's 13.86 A short-circuit current by 1.56 equals 21.62 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Auxin Solar AXN10M410B pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.75 V cold Voc at 14 F and handles 13.86 A Isc; string inverters cap Auxin Solar AXN10M410B at 14 panels on 600 V.

Is Auxin Solar AXN10M410B eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Auxin Solar AXN10M410B rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.