G-Star Pte Ltd GSP7F54M(H)395BB is a 395.0 W STC (371.8 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 36.75 V Voc at 25 C, and 40.13 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 371.8 W
- Voc @ 25C
- 36.75 V
- Efficiency
- 20.26%
How Does G-Star Pte Ltd GSP7F54M(H)395BB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for G-Star Pte Ltd GSP7F54M(H)395BB (Mono-c-Si) residential solar systems.
G-Star Pte Ltd GSP7F54M(H)395BB delivers 202.6 W/m2 (0.35 percentage points above 19.91% CEC median) and strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 41.1 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with AMPS Solar AMPS-395P-54BB (395.0 W).
Where Does G-Star Pte Ltd GSP7F54M(H)395BB Fall Across Listed CEC Models?
Comparison of G-Star Pte Ltd GSP7F54M(H)395BB (395.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define G-Star Pte Ltd GSP7F54M(H)395BB?
Relative ranking of G-Star Pte Ltd GSP7F54M(H)395BB across nameplate watts, 94.1% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for G-Star Pte Ltd GSP7F54M(H)395BB?
Summary of G-Star Pte Ltd GSP7F54M(H)395BB output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.26% Aperture Efficiency
Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.13 V at -10 C (561.8 V string) and 41.1 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 40.9 m2 (441 sq ft) producing 7,808 W PTC; NEC 690.8 OCPD floor is 21.36 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.75 * (1 + (-0.263/100) * (-10 - 25)) = 40.13 V | OCPD = 1.56 * 13.69 = 21.36 A
Inputs from CEC Modules.csv for G-Star Pte Ltd GSP7F54M(H)395BB: Voc=36.75 V, beta_Voc=-0.263%/C, Isc=13.69 A, STC=395.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (561.8 V); 21 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for G-Star Pte Ltd GSP7F54M(H)395BB?
Complete CEC test sheet for G-Star Pte Ltd GSP7F54M(H)395BB including Isc (13.69 A), Voc (36.75 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 371.8 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.75 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.85 V / 12.81 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.26% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many G-Star Pte Ltd GSP7F54M(H)395BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using G-Star Pte Ltd GSP7F54M(H)395BB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 336 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 441 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 546 sq ft | $2,570 | $4,347 |
Which Sibling Wattage & Trim Variants Belong to This G-Star Pte Ltd Series?
Related G-Star Pte Ltd power steps and black/silver trims consolidated into this G-Star Pte Ltd GSP7F54M(H)395BB series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| G-Star Pte Ltd GSP7F54M(H)390BB | 390.0 W | 367.0 W | 36.5 V | 30.65 V | 20.0% |
| G-Star Pte Ltd GSP7F54M(H)395BB | 395.0 W | 371.8 W | 36.75 V | 30.85 V | 20.26% |
How Many G-Star Pte Ltd GSP7F54M(H)395BB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for G-Star Pte Ltd GSP7F54M(H)395BB (36.75 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.1 V | 14 panels | 575.4 V | 24 panels |
| -10 C (14 F) | 40.13 V | 14 panels | 561.8 V | 24 panels |
| 0 C (32 F) | 39.17 V | 15 panels | 587.6 V | 25 panels |
| 25 C (77 F STC) | 36.75 V | 16 panels | 588.0 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to G-Star Pte Ltd GSP7F54M(H)395BB?
Four comparable CEC modules such as AMPS Solar AMPS-395P-54BB (395.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AMPS Solar AMPS-395P-54BB AMPS Solar |
395.0 W | Tie (0 W) | 36.75 V | 20.36% | 94.2% |
| Bluesun Solar CoLtd BSM395M10-54HPH Bluesun Solar CoLtd |
395.0 W | Tie (0 W) | 36.75 V | 20.23% | 93.2% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154B 395W Dehui Solar Power (Vietnam) CoLtd |
395.0 W | Tie (0 W) | 36.74 V | 20.47% | 92.1% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108E ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
395.0 W | Tie (0 W) | 36.7 V | 20.47% | 92.1% |
What Are the Design Limits and Best-Fit Uses for G-Star Pte Ltd GSP7F54M(H)395BB?
Evaluate G-Star Pte Ltd GSP7F54M(H)395BB (395.0 W STC, 36.75 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), G-Star Pte Ltd GSP7F54M(H)395BB reaches 41.1 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of G-Star Pte Ltd GSP7F54M(H)395BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
G-Star Pte Ltd GSP7F54M(H)395BB 8 kW Residential Fit
Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AMPS Solar AMPS-395P-54BB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 371.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for G-Star Pte Ltd GSP7F54M(H)395BB by G-Star Pte Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many G-Star Pte Ltd GSP7F54M(H)395BB panels fit on a 600 V winter solar string?
At -10 C (14 F), G-Star Pte Ltd GSP7F54M(H)395BB cold Voc rises from 36.75 V to 40.13 V (beta_Voc -0.263%/C), capping a 600 V string at 14 panels (561.8 V).
How much roof area does an 8 kW array of G-Star Pte Ltd GSP7F54M(H)395BB need?
An 8 kW DC system uses 21 G-Star Pte Ltd GSP7F54M(H)395BB modules (8,295 W STC / 7,808 W PTC), covering roughly 441 sq ft and saving ~$2,075/yr at 18.54 c/kWh.
How does G-Star Pte Ltd GSP7F54M(H)395BB compare against AMPS Solar AMPS-395P-54BB?
G-Star Pte Ltd GSP7F54M(H)395BB outputs 395.0 W STC (36.75 V Voc, rank #9,869 of 21,677), while AMPS Solar AMPS-395P-54BB delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)