AMPS Solar AMPS-395P-54BB is a 395.0 W STC (372.0 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.36% efficiency, 36.75 V Voc at 25 C, and 40.15 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 372.0 W
- Voc @ 25C
- 36.75 V
- Efficiency
- 20.36%
How Does AMPS Solar AMPS-395P-54BB Compare Against Peer CEC Listings?
How AMPS Solar AMPS Solar AMPS-395P-54BB handles rooftop heat (372.0 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, AMPS Solar AMPS-395P-54BB exhibits 13.69 A short-circuit current, requiring a 21.36 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #9,869 of 21,677 (15.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.7 m2 for an 8 kW system (26 panels for 10 kW). Lower 36.75 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does AMPS Solar AMPS-395P-54BB Fall Across Listed CEC Models?
Where AMPS Solar AMPS-395P-54BB (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define AMPS Solar AMPS-395P-54BB?
Percentile placement of AMPS Solar AMPS-395P-54BB across power density (203.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for AMPS Solar AMPS-395P-54BB?
Four critical engineering numbers homeowners and solar installers check first when reviewing AMPS Solar AMPS-395P-54BB specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.36% Aperture Efficiency
Power density 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.15 V at -10 C (562.1 V string) and 41.12 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 40.7 m2 (439 sq ft) producing 7,812 W PTC; NEC 690.8 OCPD floor is 21.36 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.75 * (1 + (-0.264/100) * (-10 - 25)) = 40.15 V | OCPD = 1.56 * 13.69 = 21.36 A
Inputs from CEC Modules.csv for AMPS Solar AMPS-395P-54BB: Voc=36.75 V, beta_Voc=-0.264%/C, Isc=13.69 A, STC=395.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (562.1 V); 21 panels for 8 kW (439 sq ft).
What Are the Published CEC Specifications for AMPS Solar AMPS-395P-54BB?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AMPS Solar AMPS-395P-54BB.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 372.0 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.75 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.85 V / 12.81 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.264 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.36% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many AMPS Solar AMPS-395P-54BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AMPS Solar AMPS-395P-54BB (395.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 334 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 439 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 543 sq ft | $2,570 | $4,347 |
Which Sibling Wattage & Trim Variants Belong to This AMPS Solar Series?
All closely matched AMPS Solar wattages and cosmetic trims sharing the AMPS Solar AMPS-395P-54BB architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AMPS Solar AMPS-390P-54BB | 390.0 W | 367.2 W | 36.5 V | 30.65 V | 20.1% |
| AMPS Solar AMPS-395P-54BB | 395.0 W | 372.0 W | 36.75 V | 30.85 V | 20.36% |
How Many AMPS Solar AMPS-395P-54BB Modules Fit in a Cold-Weather String?
Maximum series module counts for AMPS Solar AMPS-395P-54BB from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.12 V | 14 panels | 575.7 V | 24 panels |
| -10 C (14 F) | 40.15 V | 14 panels | 562.1 V | 24 panels |
| 0 C (32 F) | 39.18 V | 15 panels | 587.7 V | 25 panels |
| 25 C (77 F STC) | 36.75 V | 16 panels | 588.0 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to AMPS Solar AMPS-395P-54BB?
Alternative CEC solar modules from competing brands near AMPS Solar AMPS-395P-54BB (395.0 W), including Bluesun Solar CoLtd BSM395M10-54HPH.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar CoLtd BSM395M10-54HPH Bluesun Solar CoLtd |
395.0 W | Tie (0 W) | 36.75 V | 20.23% | 93.2% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154B 395W Dehui Solar Power (Vietnam) CoLtd |
395.0 W | Tie (0 W) | 36.74 V | 20.47% | 92.1% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108E ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
395.0 W | Tie (0 W) | 36.7 V | 20.47% | 92.1% |
| BYD Company Limited BYD395MLK-27 BYD Company Limited |
395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.6% |
What Are the Design Limits and Best-Fit Uses for AMPS Solar AMPS-395P-54BB?
Evaluate AMPS Solar AMPS-395P-54BB (395.0 W STC, 36.75 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AMPS Solar AMPS-395P-54BB reaches 41.12 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AMPS Solar AMPS-395P-54BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AMPS Solar AMPS-395P-54BB 8 kW Residential Fit
Needs 21 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Bluesun Solar CoLtd BSM395M10-54HPH.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 372.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AMPS Solar AMPS-395P-54BB by AMPS Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is AMPS Solar AMPS-395P-54BB PTC wattage (372.0 W) lower than STC (395.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 372.0 W PTC (94.2% retention) across AMPS Solar AMPS-395P-54BB's 1.94 m2 aperture.
Who should skip AMPS Solar AMPS-395P-54BB on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 AMPS Solar AMPS-395P-54BB panels (439 sq ft) leave unusable roof gaps vs. Bluesun Solar CoLtd BSM395M10-54HPH.
What is the 1,000 V commercial string limit for AMPS Solar AMPS-395P-54BB?
On 1,000 V commercial inverters at -10 C (40.15 V cold Voc), AMPS Solar AMPS-395P-54BB fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AMPS Solar AMPS-395P-54BB.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)