WAAREE ENERGIES LIMITED WU-240 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED WU-240 is a 240.0 W STC (213.8 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.48% efficiency, 36.0 V Voc at 25 C, and 40.51 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
240.0 W
PTC Wattage
213.8 W
Voc @ 25C
36.0 V
Efficiency
14.48%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED WU-240 Compare Against Peer CEC Listings?

How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED WU-240 handles rooftop heat (213.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, WAAREE ENERGIES LIMITED WU-240 exhibits 9.0 A short-circuit current, requiring a 14.04 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,160 of 21,677 (38.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 56.3 m2 for an 8 kW system (42 panels for 10 kW). Lower 36.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does WAAREE ENERGIES LIMITED WU-240 Fall Across Listed CEC Models?

Where WAAREE ENERGIES LIMITED WU-240 (240.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED WU-240 (240.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 240.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED WU-240?

Percentile placement of WAAREE ENERGIES LIMITED WU-240 across power density (144.8 W/m2), thermal retention, and nameplate STC wattage.

WAAREE ENERGIES LIMITED WU-240 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED WU-240 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage240.0 WPTC/STC Retention89.1%Module Efficiency14.48%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WU-240?

Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED WU-240 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #20,160 / 21,677

240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,447

14.48% Aperture Efficiency

Power density 144.8 W/m2 (5.43 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.51 V at -10 C (567.1 V string) and 41.8 V at -20 C (14 max).

8 kW Reference Array

34 Panels = 8,160 W STC

Occupies 56.3 m2 (606 sq ft) producing 7,269 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.0 * (1 + (-0.358/100) * (-10 - 25)) = 40.51 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WU-240: Voc=36.0 V, beta_Voc=-0.358%/C, Isc=9.0 A, STC=240.0 W, Area=1.657 m2.

Result: 14 panels max on 600 V (567.1 V); 34 panels for 8 kW (606 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WU-240?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED WU-240.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WU-240.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 240.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 213.8 W (89.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.0 V / 8.3 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.358 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.48% (1.657 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many WAAREE ENERGIES LIMITED WU-240 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED WU-240 (240.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.0 kW 446 sq ft $1,502 $2,539
8 kW Class 34 8.16 kW 606 sq ft $2,042 $3,454
10 kW Class 42 10.08 kW 749 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED WU-240 architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WU-240 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED WU-230 230.0 W 204.7 W 36.0 V 29.0 V 13.88%
WAAREE ENERGIES LIMITED WU-240 240.0 W 213.8 W 36.0 V 29.0 V 14.48%

How Many WAAREE ENERGIES LIMITED WU-240 Modules Fit in a Cold-Weather String?

Maximum series module counts for WAAREE ENERGIES LIMITED WU-240 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.0V and beta_Voc=-0.358%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.8 V 14 panels 585.2 V 23 panels
-10 C (14 F) 40.51 V 14 panels 567.1 V 24 panels
0 C (32 F) 39.22 V 15 panels 588.3 V 25 panels
25 C (77 F STC) 36.0 V 16 panels 576.0 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WU-240?

Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED WU-240 (240.0 W), including Chinaland Solar Energy HSE240-60P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Chinaland Solar Energy HSE240-60P
Chinaland Solar Energy
240.0 W Tie (0 W) 35.7 V 14.78% 88.4%
Chinaland Solar Energy HSE240-60P-B
Chinaland Solar Energy
240.0 W Tie (0 W) 35.7 V 14.04% 88.8%
Centrosolar America DM60 240
Centrosolar America
240.0 W Tie (0 W) 36.8 V 14.64% 90.6%
Heliene 60M240
Heliene
240.0 W Tie (0 W) 36.8 V 14.43% 90.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WU-240?

Evaluate WAAREE ENERGIES LIMITED WU-240 (240.0 W STC, 36.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WU-240 reaches 41.8 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 34 panels for an 8 kW build require 606 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (606 sq ft).
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WU-240 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED WU-240 8 kW Residential Fit

Needs 34 modules (606 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Chinaland Solar Energy HSE240-60P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 213.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WU-240 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

Why is WAAREE ENERGIES LIMITED WU-240 PTC wattage (213.8 W) lower than STC (240.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 213.8 W PTC (89.1% retention) across WAAREE ENERGIES LIMITED WU-240's 1.657 m2 aperture.

Who should skip WAAREE ENERGIES LIMITED WU-240 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 34 WAAREE ENERGIES LIMITED WU-240 panels (606 sq ft) leave unusable roof gaps vs. Chinaland Solar Energy HSE240-60P.

What is the 1,000 V commercial string limit for WAAREE ENERGIES LIMITED WU-240?

On 1,000 V commercial inverters at -10 C (40.51 V cold Voc), WAAREE ENERGIES LIMITED WU-240 fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WAAREE ENERGIES LIMITED WU-240.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.