WAAREE ENERGIES LIMITED WSMB-300 is a 300.0 W STC (275.4 W PTC) Mono-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 18.52% efficiency, 39.7 V Voc at 25 C, and 44.04 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 300.0 W
- PTC Wattage
- 275.4 W
- Voc @ 25C
- 39.7 V
- Efficiency
- 18.52%
How Does WAAREE ENERGIES LIMITED WSMB-300 Compare Against Peer CEC Listings?
Solar engineering breakdown for WAAREE ENERGIES LIMITED WSMB-300: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from WAAREE ENERGIES LIMITED and peers, WAAREE ENERGIES LIMITED WSMB-300 stands 110.0 W below the 410.0 W Mono-c-Si median and strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677). Sizing 6 kW (20 panels) to 10 kW (34 panels) yields $1,502-$2,553/yr in baseline US bill offset. Lower 39.7 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does WAAREE ENERGIES LIMITED WSMB-300 Fall Across Listed CEC Models?
Distribution marker showing WAAREE ENERGIES LIMITED WSMB-300 (300.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define WAAREE ENERGIES LIMITED WSMB-300?
Dataset percentiles tracking WAAREE ENERGIES LIMITED WSMB-300 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WSMB-300?
Benchmark highlights for WAAREE ENERGIES LIMITED WSMB-300 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
300.0 W STC · Higher Than 22.1%
300.0 W STC (-85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.52% Aperture Efficiency
Power density 185.2 W/m2 (1.39 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.04 V at -10 C (572.5 V string) and 45.27 V at -20 C (13 max).
27 Panels = 8,100 W STC
Occupies 43.7 m2 (471 sq ft) producing 7,436 W PTC; NEC 690.8 OCPD floor is 15.13 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.7 * (1 + (-0.312/100) * (-10 - 25)) = 44.04 V | OCPD = 1.56 * 9.7 = 15.13 A
Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WSMB-300: Voc=39.7 V, beta_Voc=-0.312%/C, Isc=9.7 A, STC=300.0 W, Area=1.62 m2.
Result: 13 panels max on 600 V (572.5 V); 27 panels for 8 kW (471 sq ft).
What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WSMB-300?
Official CEC datasheet figures for WAAREE ENERGIES LIMITED WSMB-300 (Mono-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 275.4 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.7 V / 9.2 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.312 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.52% (1.62 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many WAAREE ENERGIES LIMITED WSMB-300 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many WAAREE ENERGIES LIMITED WSMB-300 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.0 kW | 349 sq ft | $1,502 | $2,539 |
| 8 kW Class | 27 | 8.1 kW | 471 sq ft | $2,027 | $3,428 |
| 10 kW Class | 34 | 10.2 kW | 593 sq ft | $2,553 | $4,317 |
How Many WAAREE ENERGIES LIMITED WSMB-300 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED WSMB-300 (44.04 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.27 V | 13 panels | 588.5 V | 22 panels |
| -10 C (14 F) | 44.04 V | 13 panels | 572.5 V | 22 panels |
| 0 C (32 F) | 42.8 V | 14 panels | 599.2 V | 23 panels |
| 25 C (77 F STC) | 39.7 V | 15 panels | 595.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WSMB-300?
Competing CEC solar panels closest to WAAREE ENERGIES LIMITED WSMB-300 in nameplate wattage and Voc, starting with FreeVolt PV-GRAF-60M6-300/M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| FreeVolt PV-GRAF-60M6-300/M FreeVolt |
300.0 W | Tie (0 W) | 39.6 V | 18.29% | 91.1% |
| Enphase Energy Inc XACM-IQ7-LR6-60PB-300M Enphase Energy Inc |
300.0 W | Tie (0 W) | 40.1 V | 18.99% | 91.1% |
| CertainTeed CT300M10-03 CertainTeed |
300.0 W | Tie (0 W) | 40.3 V | 18.55% | 92.4% |
| CertainTeed CT300M11-03 CertainTeed |
300.0 W | Tie (0 W) | 40.3 V | 18.68% | 92.1% |
What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WSMB-300?
Evaluate WAAREE ENERGIES LIMITED WSMB-300 (300.0 W STC, 39.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WSMB-300 reaches 45.27 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 471 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (471 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WSMB-300 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
WAAREE ENERGIES LIMITED WSMB-300 8 kW Residential Fit
Needs 27 modules (471 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare FreeVolt PV-GRAF-60M6-300/M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 275.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for WAAREE ENERGIES LIMITED WSMB-300 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WSMB-300?
Multiplying WAAREE ENERGIES LIMITED WSMB-300's 9.7 A short-circuit current by 1.56 equals 15.13 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can WAAREE ENERGIES LIMITED WSMB-300 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.04 V cold Voc at 14 F and handles 9.7 A Isc; string inverters cap WAAREE ENERGIES LIMITED WSMB-300 at 13 panels on 600 V.
Is WAAREE ENERGIES LIMITED WSMB-300 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WSMB-300 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)