Skip to main content
WireAndSun
Calculators
CEC PV Module

WAAREE ENERGIES LIMITED BiN-21-610 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED BiN-21-610 is a 610.0 W STC (580.6 W PTC) Mono-c-Si solar module ranking #1,104 of 21,677 CEC listings (top 5.6%; higher than 94.4% of peers). It delivers 22.59% efficiency, 48.7 V Voc at 25 C, and 52.69 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
610.0 W
PTC Wattage
580.6 W
Voc @ 25C
48.7 V
Efficiency
22.59%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED BiN-21-610 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED BiN-21-610: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 610.0 W STC and 580.6 W PTC, WAAREE ENERGIES LIMITED BiN-21-610 sits +225.0 W vs all-CEC median (top 5.6%; higher than 94.4% of peers) among 21,677 listed modules. Power density reaches 225.9 W/m2 (2.68 percentage points above 19.91% CEC median). Higher 48.7 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-610 rates 610.0 W.

Where Does WAAREE ENERGIES LIMITED BiN-21-610 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED BiN-21-610 (610.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED BiN-21-610 (610.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 610.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED BiN-21-610?

Dataset percentiles tracking WAAREE ENERGIES LIMITED BiN-21-610 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

WAAREE ENERGIES LIMITED BiN-21-610 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED BiN-21-610 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage610.0 WPTC/STC Retention95.2%Module Efficiency22.59%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED BiN-21-610?

Benchmark highlights for WAAREE ENERGIES LIMITED BiN-21-610 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #1,104 / 21,677

Top 5.6% STC Output

610.0 W STC (+225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,835

22.59% Aperture Efficiency

Power density 225.9 W/m2 (2.68 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.69 V at -10 C (579.6 V string) and 53.83 V at -20 C (11 max).

8 kW Reference Array

14 Panels = 8,540 W STC

Occupies 37.8 m2 (407 sq ft) producing 8,128 W PTC; NEC 690.8 OCPD floor is 24.84 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.7 * (1 + (-0.234/100) * (-10 - 25)) = 52.69 V | OCPD = 1.56 * 15.92 = 24.84 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED BiN-21-610: Voc=48.7 V, beta_Voc=-0.234%/C, Isc=15.92 A, STC=610.0 W, Area=2.7 m2.

Result: 11 panels max on 600 V (579.6 V); 14 panels for 8 kW (407 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED BiN-21-610?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED BiN-21-610 (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED BiN-21-610.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 610.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 580.6 W (95.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 15.92 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.94 V / 14.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.234 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.59% (2.7 m2) Array roof footprint density
Cell Count & Technology 44 cells (Mono-c-Si) Bifacial glass-glass

How Many WAAREE ENERGIES LIMITED BiN-21-610 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED BiN-21-610 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.1 kW 291 sq ft $1,527 $2,582
8 kW Class 14 8.54 kW 407 sq ft $2,137 $3,614
10 kW Class 17 10.37 kW 494 sq ft $2,596 $4,389

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED BiN-21-610 mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED BiN-21-610 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED BiN-21-600 600.0 W 570.9 W 48.3 V 40.54 V 22.22%
WAAREE ENERGIES LIMITED BiN-21-605 605.0 W 575.8 W 48.5 V 40.74 V 22.41%
WAAREE ENERGIES LIMITED BiN-21-610 610.0 W 580.6 W 48.7 V 40.94 V 22.59%
WAAREE ENERGIES LIMITED BiN-21-615 615.0 W 585.5 W 48.9 V 41.14 V 22.78%
WAAREE ENERGIES LIMITED BiN-21-620 620.0 W 590.4 W 49.1 V 41.33 V 22.96%

How Many WAAREE ENERGIES LIMITED BiN-21-610 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED BiN-21-610 (52.69 V at 14 F).

Computed from Voc=48.7V and beta_Voc=-0.234%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.83 V 11 panels 592.1 V 18 panels
-10 C (14 F) 52.69 V 11 panels 579.6 V 18 panels
0 C (32 F) 51.55 V 11 panels 567.0 V 19 panels
25 C (77 F STC) 48.7 V 12 panels 584.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED BiN-21-610?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED BiN-21-610 in nameplate wattage and Voc, starting with CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-610.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-610
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI
610.0 W Tie (0 W) 48.7 V 22.76% 94.5%
Jinko Solar Co Ltd JKM610N-66HL4M-BDV
Jinko Solar Co Ltd
610.0 W Tie (0 W) 48.68 V 22.59% 94.2%
GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610
GOLDI SUN PRIVATE LIMITED
610.0 W Tie (0 W) 49.0 V 22.59% 94.1%
Mundra Solar PV Limited (Adani) AB-G12R-132-610
Mundra Solar PV Limited (Adani)
610.0 W Tie (0 W) 49.0 V 22.76% 94.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED BiN-21-610?

Evaluate WAAREE ENERGIES LIMITED BiN-21-610 (610.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED BiN-21-610 reaches 53.83 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED BiN-21-610 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED BiN-21-610 8 kW Residential Fit

Needs 14 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,137/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-610.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 580.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED BiN-21-610 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

How many WAAREE ENERGIES LIMITED BiN-21-610 panels fit on a 600 V winter solar string?

At -10 C (14 F), WAAREE ENERGIES LIMITED BiN-21-610 cold Voc rises from 48.7 V to 52.69 V (beta_Voc -0.234%/C), capping a 600 V string at 11 panels (579.6 V).

How much roof area does an 8 kW array of WAAREE ENERGIES LIMITED BiN-21-610 need?

An 8 kW DC system uses 14 WAAREE ENERGIES LIMITED BiN-21-610 modules (8,540 W STC / 8,128 W PTC), covering roughly 407 sq ft and saving ~$2,137/yr at 18.54 c/kWh.

How does WAAREE ENERGIES LIMITED BiN-21-610 compare against CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-610?

WAAREE ENERGIES LIMITED BiN-21-610 outputs 610.0 W STC (48.7 V Voc, rank #1,104 of 21,677), while CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-610 delivers 610.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls