Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED BiN-06-470 is a 470.0 W STC (444.8 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 21.96% efficiency, 43.2 V Voc at 25 C, and 46.81 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
470.0 W
PTC Wattage
444.8 W
Voc @ 25C
43.2 V
Efficiency
21.96%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED BiN-06-470 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for WAAREE ENERGIES LIMITED BiN-06-470 (Mono-c-Si) residential solar systems.

Homeowners evaluating WAAREE ENERGIES LIMITED BiN-06-470 need 13 panels for 6 kW or 18 panels (415 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.239%/C) pushes open-circuit voltage to 46.81 V at 14 F and 47.85 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does WAAREE ENERGIES LIMITED BiN-06-470 Fall Across Listed CEC Models?

Comparison of WAAREE ENERGIES LIMITED BiN-06-470 (470.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED BiN-06-470 (470.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 470.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED BiN-06-470?

Relative ranking of WAAREE ENERGIES LIMITED BiN-06-470 across nameplate watts, 94.6% PTC thermal ratio, and module aperture efficiency.

WAAREE ENERGIES LIMITED BiN-06-470 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED BiN-06-470 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage470.0 WPTC/STC Retention94.6%Module Efficiency21.96%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED BiN-06-470?

Summary of WAAREE ENERGIES LIMITED BiN-06-470 output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #4,967 / 21,677

Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,188

21.96% Aperture Efficiency

Power density 219.6 W/m2 (2.05 percentage points above 19.91% CEC median). PTC/STC ratio: 94.6% (rank #2,348).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.81 V at -10 C (561.7 V string) and 47.85 V at -20 C (12 max).

8 kW Reference Array

18 Panels = 8,460 W STC

Occupies 38.5 m2 (415 sq ft) producing 8,006 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.2 * (1 + (-0.239/100) * (-10 - 25)) = 46.81 V | OCPD = 1.56 * 13.71 = 21.39 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED BiN-06-470: Voc=43.2 V, beta_Voc=-0.239%/C, Isc=13.71 A, STC=470.0 W, Area=2.14 m2.

Result: 12 panels max on 600 V (561.7 V); 18 panels for 8 kW (415 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED BiN-06-470?

Complete CEC test sheet for WAAREE ENERGIES LIMITED BiN-06-470 including Isc (13.71 A), Voc (43.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED BiN-06-470.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 470.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 444.8 W (94.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.71 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.32 V / 12.94 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.239 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.96% (2.14 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Bifacial glass-glass

How Many WAAREE ENERGIES LIMITED BiN-06-470 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using WAAREE ENERGIES LIMITED BiN-06-470.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.11 kW 299 sq ft $1,529 $2,586
8 kW Class 18 8.46 kW 415 sq ft $2,117 $3,580
10 kW Class 22 10.34 kW 507 sq ft $2,588 $4,376

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Related WAAREE ENERGIES LIMITED power steps and black/silver trims consolidated into this WAAREE ENERGIES LIMITED BiN-06-470 series guide.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED BiN-06-470 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED BiN-06-465 465.0 W 439.9 W 43.02 V 36.16 V 21.73%
WAAREE ENERGIES LIMITED BiN-06-470 470.0 W 444.8 W 43.2 V 36.32 V 21.96%

How Many WAAREE ENERGIES LIMITED BiN-06-470 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for WAAREE ENERGIES LIMITED BiN-06-470 (43.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=43.2V and beta_Voc=-0.239%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.85 V 12 panels 574.2 V 20 panels
-10 C (14 F) 46.81 V 12 panels 561.7 V 21 panels
0 C (32 F) 45.78 V 13 panels 595.1 V 21 panels
25 C (77 F STC) 43.2 V 13 panels 561.6 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED BiN-06-470?

Four comparable CEC modules such as Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 (475.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Elin Energy (Sirius PV) ELNSM60M-HC-BF-475
Elin Energy (Sirius PV)
475.0 W +5.0 W 41.82 V 22.09% 94.5%
Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF
Boviet Solar Technology Co Ltd
460.0 W -10.0 W 43.44 V 21.3% 94.9%
Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG
Boviet Solar Technology Co Ltd
460.0 W -10.0 W 42.49 V 21.9% 94.2%
Elin Energy (Sirius PV) ELNSM60M-HC-BF-460
Elin Energy (Sirius PV)
460.0 W -10.0 W 41.52 V 21.4% 94.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED BiN-06-470?

Evaluate WAAREE ENERGIES LIMITED BiN-06-470 (470.0 W STC, 43.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED BiN-06-470 reaches 47.85 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED BiN-06-470 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED BiN-06-470 8 kW Residential Fit

Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM60M-HC-BF-475.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 444.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED BiN-06-470 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

Why is WAAREE ENERGIES LIMITED BiN-06-470 PTC wattage (444.8 W) lower than STC (470.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 444.8 W PTC (94.6% retention) across WAAREE ENERGIES LIMITED BiN-06-470's 2.14 m2 aperture.

Who should skip WAAREE ENERGIES LIMITED BiN-06-470 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 WAAREE ENERGIES LIMITED BiN-06-470 panels (415 sq ft) leave unusable roof gaps vs. Elin Energy (Sirius PV) ELNSM60M-HC-BF-475.

What is the 1,000 V commercial string limit for WAAREE ENERGIES LIMITED BiN-06-470?

On 1,000 V commercial inverters at -10 C (46.81 V cold Voc), WAAREE ENERGIES LIMITED BiN-06-470 fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WAAREE ENERGIES LIMITED BiN-06-470.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.