Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 is a 475.0 W STC (449.0 W PTC) Mono-c-Si solar module ranking #4,892 of 21,677 CEC listings (top 22.9%; higher than 77.1% of peers). It delivers 22.09% efficiency, 41.82 V Voc at 25 C, and 45.36 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 475.0 W
- PTC Wattage
- 449.0 W
- Voc @ 25C
- 41.82 V
- Efficiency
- 22.09%
How Does Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 Compare Against Peer CEC Listings?
Solar engineering breakdown for Elin Energy (Sirius PV) ELNSM60M-HC-BF-475: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Elin Energy (Sirius PV) and peers, Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 stands 65.0 W above the 410.0 W Mono-c-Si median and strong 94.5% PTC-to-STC heat retention (#2,573 of 21,677). Sizing 6 kW (13 panels) to 10 kW (22 panels) yields $1,544-$2,616/yr in baseline US bill offset. Mid-range 41.82 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 Fall Across Listed CEC Models?
Distribution marker showing Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 (475.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM60M-HC-BF-475?
Dataset percentiles tracking Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM60M-HC-BF-475?
Benchmark highlights for Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 22.9% STC Output
475.0 W STC (+90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.09% Aperture Efficiency
Power density 220.9 W/m2 (2.18 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.36 V at -10 C (589.7 V string) and 46.37 V at -20 C (12 max).
17 Panels = 8,075 W STC
Occupies 36.5 m2 (393 sq ft) producing 7,633 W PTC; NEC 690.8 OCPD floor is 22.25 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.82 * (1 + (-0.242/100) * (-10 - 25)) = 45.36 V | OCPD = 1.56 * 14.26 = 22.25 A
Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM60M-HC-BF-475: Voc=41.82 V, beta_Voc=-0.242%/C, Isc=14.26 A, STC=475.0 W, Area=2.15 m2.
Result: 13 panels max on 600 V (589.7 V); 17 panels for 8 kW (393 sq ft).
What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM60M-HC-BF-475?
Official CEC datasheet figures for Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 475.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 449.0 W (94.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.82 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.26 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.78 V / 13.63 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.242 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.09% (2.15 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.17 kW | 301 sq ft | $1,544 | $2,611 |
| 8 kW Class | 17 | 8.07 kW | 393 sq ft | $2,020 | $3,415 |
| 10 kW Class | 22 | 10.45 kW | 509 sq ft | $2,616 | $4,423 |
How Many Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 (45.36 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.37 V | 12 panels | 556.4 V | 21 panels |
| -10 C (14 F) | 45.36 V | 13 panels | 589.7 V | 22 panels |
| 0 C (32 F) | 44.35 V | 13 panels | 576.6 V | 22 panels |
| 25 C (77 F STC) | 41.82 V | 14 panels | 585.5 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM60M-HC-BF-475?
Competing CEC solar panels closest to Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG Boviet Solar Technology Co Ltd |
460.0 W | -15.0 W | 42.49 V | 21.9% | 94.2% |
| Boviet Solar Technology Co Ltd BVM7610M-485-H-HC-BF Boviet Solar Technology Co Ltd |
485.0 W | +10.0 W | 44.39 V | 22.45% | 95.0% |
| Aptos Solar Technology LLC DNA-120-BF10-455W-USAptos2 Aptos Solar Technology LLC |
455.0 W | -20.0 W | 41.7 V | 21.26% | 94.4% |
| Aptos Solar Technology LLC DNA-120-BF10-455W-USAptos1 Aptos Solar Technology LLC |
455.0 W | -20.0 W | 41.65 V | 21.26% | 94.4% |
What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM60M-HC-BF-475?
Evaluate Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 (475.0 W STC, 41.82 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 reaches 46.37 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 393 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (393 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 8 kW Residential Fit
Needs 17 modules (393 sq ft) with a 25 A string OCPD, offsetting ~$2,020/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 449.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Elin Energy (Sirius PV) ELNSM60M-HC-BF-475?
Multiplying Elin Energy (Sirius PV) ELNSM60M-HC-BF-475's 14.26 A short-circuit current by 1.56 equals 22.25 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.36 V cold Voc at 14 F and handles 14.26 A Isc; string inverters cap Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 at 13 panels on 600 V.
Is Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 rely on utility bill offset (~$2,020/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)