Skip to main content
WireAndSun
Calculators
CEC PV Module

Elin Energy (Sirius PV) ELNSM78M-HC-590 — CEC Solar Module Specifications

Manufacturer: Elin Energy (Sirius PV) Registry: CEC Verified Engineering Specification

Elin Energy (Sirius PV) ELNSM78M-HC-590 is a 590.0 W STC (556.4 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 21.3% efficiency, 53.83 V Voc at 25 C, and 58.24 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
590.0 W
PTC Wattage
556.4 W
Voc @ 25C
53.83 V
Efficiency
21.3%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Elin Energy (Sirius PV) ELNSM78M-HC-590 Compare Against Peer CEC Listings?

How Elin Energy (Sirius PV) Elin Energy (Sirius PV) ELNSM78M-HC-590 handles rooftop heat (556.4 W PTC), 8 kW sizing, and cold winter string voltage.

Elin Energy (Sirius PV) builds the Elin Energy (Sirius PV) ELNSM78M-HC-590 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 213.0 W/m2 (1.39 percentage points above 19.91% CEC median). Compared against GermanSolar USA Inc GSM10-144-590W (590.0 W), this model holds strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677). Higher 53.83 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 21.73 A overcurrent floor served by a 25 A breaker.

Where Does Elin Energy (Sirius PV) ELNSM78M-HC-590 Fall Across Listed CEC Models?

Where Elin Energy (Sirius PV) ELNSM78M-HC-590 (590.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Elin Energy (Sirius PV) ELNSM78M-HC-590 (590.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCElin Energy (Siriu: 590.0 W

What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM78M-HC-590?

Percentile placement of Elin Energy (Sirius PV) ELNSM78M-HC-590 across power density (213.0 W/m2), thermal retention, and nameplate STC wattage.

Elin Energy (Sirius PV) ELNSM78M-HC-590 Engineering BenchmarksPercentile comparison of Elin Energy (Sirius PV) ELNSM78M-HC-590 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage590.0 WPTC/STC Retention94.3%Module Efficiency21.3%

What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM78M-HC-590?

Four critical engineering numbers homeowners and solar installers check first when reviewing Elin Energy (Sirius PV) ELNSM78M-HC-590 specifications.

Rank #1,597 / 21,677

Top 8.1% STC Output

590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,110

21.3% Aperture Efficiency

Power density 213.0 W/m2 (1.39 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.24 V at -10 C (582.4 V string) and 59.5 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,260 W STC

Occupies 38.8 m2 (417 sq ft) producing 7,790 W PTC; NEC 690.8 OCPD floor is 21.73 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.83 * (1 + (-0.234/100) * (-10 - 25)) = 58.24 V | OCPD = 1.56 * 13.93 = 21.73 A

Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM78M-HC-590: Voc=53.83 V, beta_Voc=-0.234%/C, Isc=13.93 A, STC=590.0 W, Area=2.77 m2.

Result: 10 panels max on 600 V (582.4 V); 14 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM78M-HC-590?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Elin Energy (Sirius PV) ELNSM78M-HC-590.

Official California Energy Commission (NREL SAM) test parameters for Elin Energy (Sirius PV) ELNSM78M-HC-590.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 590.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 556.4 W (94.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 53.83 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.93 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 45.21 V / 13.06 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.234 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.3% (2.77 m2) Array roof footprint density
Cell Count & Technology 78 cells (Mono-c-Si) Monofacial backsheet

How Many Elin Energy (Sirius PV) ELNSM78M-HC-590 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Elin Energy (Sirius PV) ELNSM78M-HC-590 (590.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.49 kW 328 sq ft $1,624 $2,747
8 kW Class 14 8.26 kW 417 sq ft $2,067 $3,496
10 kW Class 17 10.03 kW 507 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This Elin Energy (Sirius PV) Series?

All closely matched Elin Energy (Sirius PV) wattages and cosmetic trims sharing the Elin Energy (Sirius PV) ELNSM78M-HC-590 architecture.

Sibling CEC listings grouped into the Elin Energy (Sirius PV) ELNSM78M-HC-590 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Elin Energy (Sirius PV) ELNSM78M-HC-580 580.0 W 546.8 W 53.43 V 44.81 V 20.94%
Elin Energy (Sirius PV) ELNSM78M-HC-585 585.0 W 551.6 W 53.63 V 45.01 V 21.12%
Elin Energy (Sirius PV) ELNSM78M-HC-590 590.0 W 556.4 W 53.83 V 45.21 V 21.3%
Elin Energy (Sirius PV) ELNSM78M-HC-595 595.0 W 561.2 W 54.03 V 45.41 V 21.48%

How Many Elin Energy (Sirius PV) ELNSM78M-HC-590 Modules Fit in a Cold-Weather String?

Maximum series module counts for Elin Energy (Sirius PV) ELNSM78M-HC-590 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=53.83V and beta_Voc=-0.234%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 59.5 V 10 panels 595.0 V 16 panels
-10 C (14 F) 58.24 V 10 panels 582.4 V 17 panels
0 C (32 F) 56.98 V 10 panels 569.8 V 17 panels
25 C (77 F STC) 53.83 V 11 panels 592.1 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM78M-HC-590?

Alternative CEC solar modules from competing brands near Elin Energy (Sirius PV) ELNSM78M-HC-590 (590.0 W), including GermanSolar USA Inc GSM10-144-590W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GermanSolar USA Inc GSM10-144-590W
GermanSolar USA Inc
590.0 W Tie (0 W) 54.31 V 24.48% 95.2%
Allesun Industries Inc Allesun-585-78IIMBG
Allesun Industries Inc
585.0 W -5.0 W 53.73 V 20.97% 94.0%
G-Star Pte Ltd GSD7G78M-585BT
G-Star Pte Ltd
585.0 W -5.0 W 53.73 V 21.12% 94.3%
G-Star Pte Ltd GSD7G78M-585WT
G-Star Pte Ltd
585.0 W -5.0 W 53.73 V 21.12% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM78M-HC-590?

Evaluate Elin Energy (Sirius PV) ELNSM78M-HC-590 (590.0 W STC, 53.83 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM78M-HC-590 reaches 59.5 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM78M-HC-590 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Elin Energy (Sirius PV) ELNSM78M-HC-590 8 kW Residential Fit

Needs 14 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare GermanSolar USA Inc GSM10-144-590W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 556.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Elin Energy (Sirius PV) ELNSM78M-HC-590 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Elin Energy (Sirius PV) ELNSM78M-HC-590?

Multiplying Elin Energy (Sirius PV) ELNSM78M-HC-590's 13.93 A short-circuit current by 1.56 equals 21.73 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Elin Energy (Sirius PV) ELNSM78M-HC-590 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 58.24 V cold Voc at 14 F and handles 13.93 A Isc; string inverters cap Elin Energy (Sirius PV) ELNSM78M-HC-590 at 10 panels on 600 V.

Is Elin Energy (Sirius PV) ELNSM78M-HC-590 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Elin Energy (Sirius PV) ELNSM78M-HC-590 rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.