Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 is a 590.0 W STC (556.4 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 21.3% efficiency, 53.83 V Voc at 25 C, and 58.24 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 590.0 W
- PTC Wattage
- 556.4 W
- Voc @ 25C
- 53.83 V
- Efficiency
- 21.3%
How Does Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 Compare Against Peer CEC Listings?
Engineering position of Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 (590.0 W STC) vs. GermanSolar USA Inc GSM10-144-590W across 5,889 CEC Mono-c-Si solar modules.
Ranking #1,597 across 21,677 CEC solar panels (top 8.1%; higher than 91.9% of peers), Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 operates as a large-format commercial and ground-mount module sitting 180.0 W above the 410.0 W Mono-c-Si median. Higher 53.83 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677), 14 panels occupy 417 sq ft and offset roughly $2,067/yr at average US rates (or $3,496/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 Fall Across Listed CEC Models?
Plots Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 at 590.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM78M-HC-LV-590?
Benchmarks Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 on STC wattage, thermal PTC/STC retention, and 21.3 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM78M-HC-LV-590?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 by Elin Energy (Sirius PV).
Top 8.1% STC Output
590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.3% Aperture Efficiency
Power density 213.0 W/m2 (1.39 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 58.24 V at -10 C (582.4 V string) and 59.5 V at -20 C (10 max).
14 Panels = 8,260 W STC
Occupies 38.8 m2 (417 sq ft) producing 7,790 W PTC; NEC 690.8 OCPD floor is 21.73 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.83 * (1 + (-0.234/100) * (-10 - 25)) = 58.24 V | OCPD = 1.56 * 13.93 = 21.73 A
Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM78M-HC-LV-590: Voc=53.83 V, beta_Voc=-0.234%/C, Isc=13.93 A, STC=590.0 W, Area=2.77 m2.
Result: 10 panels max on 600 V (582.4 V); 14 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM78M-HC-LV-590?
Laboratory test ratings recorded for Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 590.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 556.4 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.83 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.93 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.21 V / 13.06 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.234 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.3% (2.77 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (417 sq ft at 8 kW), and estimated Year-1 electric bill offset for Elin Energy (Sirius PV) ELNSM78M-HC-LV-590.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.49 kW | 328 sq ft | $1,624 | $2,747 |
| 8 kW Class | 14 | 8.26 kW | 417 sq ft | $2,067 | $3,496 |
| 10 kW Class | 17 | 10.03 kW | 507 sq ft | $2,510 | $4,245 |
Which Sibling Wattage & Trim Variants Belong to This Elin Energy (Sirius PV) Series?
Sibling wattage bins and frame colors grouped with Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 under Elin Energy (Sirius PV) to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM78M-HC-LV-580 | 580.0 W | 546.8 W | 53.43 V | 44.81 V | 20.94% |
| Elin Energy (Sirius PV) ELNSM78M-HC-LV-585 | 585.0 W | 551.6 W | 53.63 V | 45.01 V | 21.12% |
| Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 | 590.0 W | 556.4 W | 53.83 V | 45.21 V | 21.3% |
| Elin Energy (Sirius PV) ELNSM78M-HC-LV-595 | 595.0 W | 561.2 W | 54.03 V | 45.41 V | 21.48% |
How Many Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 (beta_Voc -0.234%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 59.5 V | 10 panels | 595.0 V | 16 panels |
| -10 C (14 F) | 58.24 V | 10 panels | 582.4 V | 17 panels |
| 0 C (32 F) | 56.98 V | 10 panels | 569.8 V | 17 panels |
| 25 C (77 F STC) | 53.83 V | 11 panels | 592.1 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM78M-HC-LV-590?
Closest cross-brand CEC competitors to Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 matched near 590.0 W STC and 53.83 V Voc, led by GermanSolar USA Inc GSM10-144-590W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GermanSolar USA Inc GSM10-144-590W GermanSolar USA Inc |
590.0 W | Tie (0 W) | 54.31 V | 24.48% | 95.2% |
| Allesun Industries Inc Allesun-585-78IIMBG Allesun Industries Inc |
585.0 W | -5.0 W | 53.73 V | 20.97% | 94.0% |
| G-Star Pte Ltd GSD7G78M-585BT G-Star Pte Ltd |
585.0 W | -5.0 W | 53.73 V | 21.12% | 94.3% |
| G-Star Pte Ltd GSD7G78M-585WT G-Star Pte Ltd |
585.0 W | -5.0 W | 53.73 V | 21.12% | 94.3% |
What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM78M-HC-LV-590?
Evaluate Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 (590.0 W STC, 53.83 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 reaches 59.5 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 8 kW Residential Fit
Needs 14 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare GermanSolar USA Inc GSM10-144-590W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 556.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.
How many Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 panels fit on a 600 V winter solar string?
At -10 C (14 F), Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 cold Voc rises from 53.83 V to 58.24 V (beta_Voc -0.234%/C), capping a 600 V string at 10 panels (582.4 V).
How much roof area does an 8 kW array of Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 need?
An 8 kW DC system uses 14 Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 modules (8,260 W STC / 7,790 W PTC), covering roughly 417 sq ft and saving ~$2,067/yr at 18.54 c/kWh.
How does Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 compare against GermanSolar USA Inc GSM10-144-590W?
Elin Energy (Sirius PV) ELNSM78M-HC-LV-590 outputs 590.0 W STC (53.83 V Voc, rank #1,597 of 21,677), while GermanSolar USA Inc GSM10-144-590W delivers 590.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)