Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 is a 460.0 W STC (434.4 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 21.4% efficiency, 41.52 V Voc at 25 C, and 45.04 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 460.0 W
- PTC Wattage
- 434.4 W
- Voc @ 25C
- 41.52 V
- Efficiency
- 21.4%
How Does Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 Compare Against Peer CEC Listings?
How Elin Energy (Sirius PV) Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 handles rooftop heat (434.4 W PTC), 8 kW sizing, and cold winter string voltage.
Elin Energy (Sirius PV) builds the Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 214.0 W/m2 (1.49 percentage points above 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG (460.0 W), this model holds strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Mid-range 41.52 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 21.78 A overcurrent floor served by a 25 A breaker.
Where Does Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 Fall Across Listed CEC Models?
Where Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 (460.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM60M-HC-BF-460?
Percentile placement of Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 across power density (214.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM60M-HC-BF-460?
Four critical engineering numbers homeowners and solar installers check first when reviewing Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 specifications.
Top 25.0% STC Output
460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.4% Aperture Efficiency
Power density 214.0 W/m2 (1.49 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.04 V at -10 C (585.5 V string) and 46.04 V at -20 C (13 max).
18 Panels = 8,280 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,819 W PTC; NEC 690.8 OCPD floor is 21.78 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.52 * (1 + (-0.242/100) * (-10 - 25)) = 45.04 V | OCPD = 1.56 * 13.96 = 21.78 A
Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM60M-HC-BF-460: Voc=41.52 V, beta_Voc=-0.242%/C, Isc=13.96 A, STC=460.0 W, Area=2.15 m2.
Result: 13 panels max on 600 V (585.5 V); 18 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM60M-HC-BF-460?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Elin Energy (Sirius PV) ELNSM60M-HC-BF-460.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 434.4 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.52 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.96 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.48 V / 13.33 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.242 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.4% (2.15 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 (460.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.44 kW | 324 sq ft | $1,612 | $2,726 |
| 8 kW Class | 18 | 8.28 kW | 417 sq ft | $2,072 | $3,504 |
| 10 kW Class | 22 | 10.12 kW | 509 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This Elin Energy (Sirius PV) Series?
All closely matched Elin Energy (Sirius PV) wattages and cosmetic trims sharing the Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-450 | 450.0 W | 424.8 W | 41.32 V | 34.28 V | 20.93% |
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-455 | 455.0 W | 429.6 W | 41.42 V | 34.38 V | 21.16% |
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 | 460.0 W | 434.4 W | 41.52 V | 34.48 V | 21.4% |
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-465 | 465.0 W | 439.3 W | 41.62 V | 34.58 V | 21.63% |
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-470 | 470.0 W | 444.1 W | 41.72 V | 34.68 V | 21.86% |
How Many Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 Modules Fit in a Cold-Weather String?
Maximum series module counts for Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.04 V | 13 panels | 598.5 V | 21 panels |
| -10 C (14 F) | 45.04 V | 13 panels | 585.5 V | 22 panels |
| 0 C (32 F) | 44.03 V | 13 panels | 572.4 V | 22 panels |
| 25 C (77 F STC) | 41.52 V | 14 panels | 581.3 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM60M-HC-BF-460?
Alternative CEC solar modules from competing brands near Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 (460.0 W), including Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG Boviet Solar Technology Co Ltd |
460.0 W | Tie (0 W) | 42.49 V | 21.9% | 94.2% |
| Aptos Solar Technology LLC DNA-120-BF10-455W Aptos Solar Technology LLC |
455.0 W | -5.0 W | 41.51 V | 21.26% | 92.7% |
| Dehui Solar Power (Vietnam) CoLtd DH-M160T 455W Dehui Solar Power (Vietnam) CoLtd |
455.0 W | -5.0 W | 41.51 V | 21.26% | 92.7% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
455.0 W | -5.0 W | 41.5 V | 21.26% | 92.7% |
What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM60M-HC-BF-460?
Evaluate Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 (460.0 W STC, 41.52 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 reaches 46.04 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 417 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (417 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 8 kW Residential Fit
Needs 18 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 434.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Elin Energy (Sirius PV) ELNSM60M-HC-BF-460?
Multiplying Elin Energy (Sirius PV) ELNSM60M-HC-BF-460's 13.96 A short-circuit current by 1.56 equals 21.78 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.04 V cold Voc at 14 F and handles 13.96 A Isc; string inverters cap Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 at 13 panels on 600 V.
Is Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)