US Solar USS-QCMO3-60-260 is a 260.0 W STC (236.0 W PTC) Mono-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.86% efficiency, 38.2 V Voc at 25 C, and 42.53 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 236.0 W
- Voc @ 25C
- 38.2 V
- Efficiency
- 15.86%
How Does US Solar USS-QCMO3-60-260 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for US Solar USS-QCMO3-60-260 (Mono-c-Si) residential solar systems.
US Solar USS-QCMO3-60-260 delivers 158.5 W/m2 (4.05 percentage points below 19.91% CEC median) and typical 90.8% PTC-to-STC thermal output (236.0 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (547 sq ft). At -4 F (-20 C), string voltage climbs to 43.77 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Centrosolar America DM60 260 (260.0 W).
Where Does US Solar USS-QCMO3-60-260 Fall Across Listed CEC Models?
Comparison of US Solar USS-QCMO3-60-260 (260.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define US Solar USS-QCMO3-60-260?
Relative ranking of US Solar USS-QCMO3-60-260 across nameplate watts, 90.8% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for US Solar USS-QCMO3-60-260?
Summary of US Solar USS-QCMO3-60-260 output rank, 8 kW array size (31 panels), efficiency rating, and 600 V string limit.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.86% Aperture Efficiency
Power density 158.5 W/m2 (4.05 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.53 V at -10 C (595.4 V string) and 43.77 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 50.8 m2 (547 sq ft) producing 7,316 W PTC; NEC 690.8 OCPD floor is 13.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.2 * (1 + (-0.324/100) * (-10 - 25)) = 42.53 V | OCPD = 1.56 * 8.8 = 13.73 A
Inputs from CEC Modules.csv for US Solar USS-QCMO3-60-260: Voc=38.2 V, beta_Voc=-0.324%/C, Isc=8.8 A, STC=260.0 W, Area=1.64 m2.
Result: 14 panels max on 600 V (595.4 V); 31 panels for 8 kW (547 sq ft).
What Are the Published CEC Specifications for US Solar USS-QCMO3-60-260?
Complete CEC test sheet for US Solar USS-QCMO3-60-260 including Isc (8.8 A), Voc (38.2 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 236.0 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.4 V / 8.3 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.324 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.86% (1.64 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many US Solar USS-QCMO3-60-260 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using US Solar USS-QCMO3-60-260.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 424 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 547 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 688 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This US Solar Series?
Related US Solar power steps and black/silver trims consolidated into this US Solar USS-QCMO3-60-260 series guide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| US Solar USS-QCMO3-60-250 | 250.0 W | 226.7 W | 37.4 V | 30.6 V | 15.25% |
| US Solar USS-QCMO3-60-255 | 255.0 W | 231.4 W | 37.9 V | 31.1 V | 15.55% |
| US Solar USS-QCMO3-60-260 | 260.0 W | 236.0 W | 38.2 V | 31.4 V | 15.86% |
| US Solar USS-QCMO3-60-265 | 265.0 W | 240.7 W | 38.5 V | 32.0 V | 16.16% |
| US Solar USS-QCMO3-60-270 | 270.0 W | 245.3 W | 38.8 V | 32.2 V | 16.47% |
How Many US Solar USS-QCMO3-60-260 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for US Solar USS-QCMO3-60-260 (38.2 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.77 V | 13 panels | 569.0 V | 22 panels |
| -10 C (14 F) | 42.53 V | 14 panels | 595.4 V | 23 panels |
| 0 C (32 F) | 41.29 V | 14 panels | 578.1 V | 24 panels |
| 25 C (77 F STC) | 38.2 V | 15 panels | 573.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMO3-60-260?
Four comparable CEC modules such as Centrosolar America DM60 260 (260.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DM60 260 Centrosolar America |
260.0 W | Tie (0 W) | 38.2 V | 15.86% | 90.8% |
| Centrosolar America DP60 260 Centrosolar America |
260.0 W | Tie (0 W) | 38.28 V | 15.86% | 90.2% |
| BYD Company Limited BYD 260P6C-30 BYD Company Limited |
260.0 W | Tie (0 W) | 38.38 V | 15.98% | 90.4% |
| BYD Company Limited BYD260P6K-30 BYD Company Limited |
260.0 W | Tie (0 W) | 38.38 V | 15.95% | 91.7% |
What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMO3-60-260?
Evaluate US Solar USS-QCMO3-60-260 (260.0 W STC, 38.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMO3-60-260 reaches 43.77 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (547 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMO3-60-260 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
US Solar USS-QCMO3-60-260 8 kW Residential Fit
Needs 31 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America DM60 260.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 236.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for US Solar USS-QCMO3-60-260 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many US Solar USS-QCMO3-60-260 panels fit on a 600 V winter solar string?
At -10 C (14 F), US Solar USS-QCMO3-60-260 cold Voc rises from 38.2 V to 42.53 V (beta_Voc -0.324%/C), capping a 600 V string at 14 panels (595.4 V).
How much roof area does an 8 kW array of US Solar USS-QCMO3-60-260 need?
An 8 kW DC system uses 31 US Solar USS-QCMO3-60-260 modules (8,060 W STC / 7,316 W PTC), covering roughly 547 sq ft and saving ~$2,017/yr at 18.54 c/kWh.
How does US Solar USS-QCMO3-60-260 compare against Centrosolar America DM60 260?
US Solar USS-QCMO3-60-260 outputs 260.0 W STC (38.2 V Voc, rank #19,146 of 21,677), while Centrosolar America DM60 260 delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)