US Solar USS-QCMI3-60-260 is a 260.0 W STC (234.4 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.86% efficiency, 38.28 V Voc at 25 C, and 42.82 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 234.4 W
- Voc @ 25C
- 38.28 V
- Efficiency
- 15.86%
How Does US Solar USS-QCMI3-60-260 Compare Against Peer CEC Listings?
Engineering position of US Solar USS-QCMI3-60-260 (260.0 W STC) vs. Centrosolar America DP60 260 across 1,407 CEC Multi-c-Si solar modules.
Ranking #19,146 across 21,677 CEC solar panels (below all-CEC median; higher than 10.4% of peers), US Solar USS-QCMI3-60-260 operates as a compact residential or specialty off-grid module sitting 18.8 W below the 278.8 W Multi-c-Si median. Lower 38.28 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 90.2% PTC-to-STC thermal output (234.4 W real-world rating), 31 panels occupy 547 sq ft and offset roughly $2,017/yr at average US rates (or $3,411/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does US Solar USS-QCMI3-60-260 Fall Across Listed CEC Models?
Plots US Solar USS-QCMI3-60-260 at 260.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define US Solar USS-QCMI3-60-260?
Benchmarks US Solar USS-QCMI3-60-260 on STC wattage, thermal PTC/STC retention, and 15.86 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for US Solar USS-QCMI3-60-260?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for US Solar USS-QCMI3-60-260 by US Solar.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.86% Aperture Efficiency
Power density 158.5 W/m2 (4.05 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.82 V at -10 C (599.5 V string) and 44.12 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 50.8 m2 (547 sq ft) producing 7,266 W PTC; NEC 690.8 OCPD floor is 13.57 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.28 * (1 + (-0.339/100) * (-10 - 25)) = 42.82 V | OCPD = 1.56 * 8.7 = 13.57 A
Inputs from CEC Modules.csv for US Solar USS-QCMI3-60-260: Voc=38.28 V, beta_Voc=-0.339%/C, Isc=8.7 A, STC=260.0 W, Area=1.64 m2.
Result: 14 panels max on 600 V (599.5 V); 31 panels for 8 kW (547 sq ft).
What Are the Published CEC Specifications for US Solar USS-QCMI3-60-260?
Laboratory test ratings recorded for US Solar USS-QCMI3-60-260 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 234.4 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.28 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.71 V / 8.2 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.339 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.86% (1.64 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many US Solar USS-QCMI3-60-260 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (547 sq ft at 8 kW), and estimated Year-1 electric bill offset for US Solar USS-QCMI3-60-260.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 424 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 547 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 688 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This US Solar Series?
Sibling wattage bins and frame colors grouped with US Solar USS-QCMI3-60-260 under US Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| US Solar USS-QCMI3-60-250 | 250.0 W | 225.2 W | 38.12 V | 30.71 V | 15.25% |
| US Solar USS-QCMI3-60-255 | 255.0 W | 229.8 W | 38.2 V | 31.25 V | 15.55% |
| US Solar USS-QCMI3-60-260 | 260.0 W | 234.4 W | 38.28 V | 31.71 V | 15.86% |
| US Solar USS-QCMI3-60-265 | 265.0 W | 239.1 W | 38.4 V | 32.2 V | 16.16% |
| US Solar USS-QCMI3-60-270 | 270.0 W | 243.7 W | 38.6 V | 32.46 V | 16.47% |
How Many US Solar USS-QCMI3-60-260 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for US Solar USS-QCMI3-60-260 (beta_Voc -0.339%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.12 V | 13 panels | 573.6 V | 22 panels |
| -10 C (14 F) | 42.82 V | 14 panels | 599.5 V | 23 panels |
| 0 C (32 F) | 41.52 V | 14 panels | 581.3 V | 24 panels |
| 25 C (77 F STC) | 38.28 V | 15 panels | 574.2 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI3-60-260?
Closest cross-brand CEC competitors to US Solar USS-QCMI3-60-260 matched near 260.0 W STC and 38.28 V Voc, led by Centrosolar America DP60 260.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP60 260 Centrosolar America |
260.0 W | Tie (0 W) | 38.28 V | 15.86% | 90.2% |
| Centrosolar America DM60 260 Centrosolar America |
260.0 W | Tie (0 W) | 38.2 V | 15.86% | 90.8% |
| BYD Company Limited BYD 260P6C-30 BYD Company Limited |
260.0 W | Tie (0 W) | 38.38 V | 15.98% | 90.4% |
| BYD Company Limited BYD260P6K-30 BYD Company Limited |
260.0 W | Tie (0 W) | 38.38 V | 15.95% | 91.7% |
What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI3-60-260?
Evaluate US Solar USS-QCMI3-60-260 (260.0 W STC, 38.28 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI3-60-260 reaches 44.12 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (547 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI3-60-260 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
US Solar USS-QCMI3-60-260 8 kW Residential Fit
Needs 31 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America DP60 260.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 234.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for US Solar USS-QCMI3-60-260 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many US Solar USS-QCMI3-60-260 panels fit on a 600 V winter solar string?
At -10 C (14 F), US Solar USS-QCMI3-60-260 cold Voc rises from 38.28 V to 42.82 V (beta_Voc -0.339%/C), capping a 600 V string at 14 panels (599.5 V).
How much roof area does an 8 kW array of US Solar USS-QCMI3-60-260 need?
An 8 kW DC system uses 31 US Solar USS-QCMI3-60-260 modules (8,060 W STC / 7,266 W PTC), covering roughly 547 sq ft and saving ~$2,017/yr at 18.54 c/kWh.
How does US Solar USS-QCMI3-60-260 compare against Centrosolar America DP60 260?
US Solar USS-QCMI3-60-260 outputs 260.0 W STC (38.28 V Voc, rank #19,146 of 21,677), while Centrosolar America DP60 260 delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)