Skip to main content
WireAndSun
Calculators
CEC PV Module

US Solar USS-QCMI2-72-270 — CEC Solar Module Specifications

Manufacturer: US Solar Registry: CEC Verified Engineering Specification

US Solar USS-QCMI2-72-270 is a 270.0 W STC (238.6 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.89% efficiency, 43.85 V Voc at 25 C, and 49.38 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
238.6 W
Voc @ 25C
43.85 V
Efficiency
13.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does US Solar USS-QCMI2-72-270 Compare Against Peer CEC Listings?

Solar engineering breakdown for US Solar USS-QCMI2-72-270: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Measured at 270.0 W STC and 238.6 W PTC, US Solar USS-QCMI2-72-270 sits -115.0 W vs all-CEC median (below all-CEC median; higher than 12.9% of peers) among 21,677 listed modules. Power density reaches 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). Mid-range 43.85 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer Centrosolar America DP72 270 rates 270.0 W.

Where Does US Solar USS-QCMI2-72-270 Fall Across Listed CEC Models?

Distribution marker showing US Solar USS-QCMI2-72-270 (270.0 W) relative to the 385.0 W all-CEC solar panel median. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where US Solar USS-QCMI2-72-270 (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUS Solar USS-QCMI2: 270.0 W

What Dataset Percentiles Define US Solar USS-QCMI2-72-270?

Dataset percentiles tracking US Solar USS-QCMI2-72-270 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

US Solar USS-QCMI2-72-270 Engineering BenchmarksPercentile comparison of US Solar USS-QCMI2-72-270 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention88.4%Module Efficiency13.89%

What Do the Dataset Ranks Show for US Solar USS-QCMI2-72-270?

Benchmark highlights for US Solar USS-QCMI2-72-270 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,983

13.89% Aperture Efficiency

Power density 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.38 V at -10 C (592.6 V string) and 50.95 V at -20 C (11 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 58.3 m2 (628 sq ft) producing 7,158 W PTC; NEC 690.8 OCPD floor is 12.62 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.85 * (1 + (-0.36/100) * (-10 - 25)) = 49.38 V | OCPD = 1.56 * 8.09 = 12.62 A

Inputs from CEC Modules.csv for US Solar USS-QCMI2-72-270: Voc=43.85 V, beta_Voc=-0.36%/C, Isc=8.09 A, STC=270.0 W, Area=1.944 m2.

Result: 12 panels max on 600 V (592.6 V); 30 panels for 8 kW (628 sq ft).

What Are the Published CEC Specifications for US Solar USS-QCMI2-72-270?

Official CEC datasheet figures for US Solar USS-QCMI2-72-270 (Multi-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMI2-72-270.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 238.6 W (88.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.85 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.09 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.55 V / 7.59 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.89% (1.944 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many US Solar USS-QCMI2-72-270 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many US Solar USS-QCMI2-72-270 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 481 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 628 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 795 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

Consolidated US Solar wattage variants sharing the US Solar USS-QCMI2-72-270 mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the US Solar USS-QCMI2-72-270 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
US Solar USS-QCMI2-72-265 265.0 W 234.1 W 43.5 V 35.48 V 13.63%
US Solar USS-QCMI2-72-270 270.0 W 238.6 W 43.85 V 35.55 V 13.89%

How Many US Solar USS-QCMI2-72-270 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on US Solar USS-QCMI2-72-270 (49.38 V at 14 F).

Computed from Voc=43.85V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.95 V 11 panels 560.5 V 19 panels
-10 C (14 F) 49.38 V 12 panels 592.6 V 20 panels
0 C (32 F) 47.8 V 12 panels 573.6 V 20 panels
25 C (77 F STC) 43.85 V 13 panels 570.1 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI2-72-270?

Competing CEC solar panels closest to US Solar USS-QCMI2-72-270 in nameplate wattage and Voc, starting with Centrosolar America DP72 270.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DP72 270
Centrosolar America
270.0 W Tie (0 W) 43.85 V 13.89% 88.4%
Anhui Rinengzhongtian Semiconductor Development QJM270-72
Anhui Rinengzhongtian Semiconductor Development
270.0 W Tie (0 W) 43.67 V 13.92% 89.6%
AXITEC AC-270P/156-72S
AXITEC
270.0 W Tie (0 W) 44.18 V 13.94% 89.9%
Advance Power API-M270
Advance Power
270.0 W Tie (0 W) 44.64 V 13.84% 89.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI2-72-270?

Evaluate US Solar USS-QCMI2-72-270 (270.0 W STC, 43.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI2-72-270 reaches 50.95 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 628 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (628 sq ft).
  • 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI2-72-270 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

US Solar USS-QCMI2-72-270 8 kW Residential Fit

Needs 30 modules (628 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DP72 270.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 238.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMI2-72-270 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many US Solar USS-QCMI2-72-270 panels fit on a 600 V winter solar string?

At -10 C (14 F), US Solar USS-QCMI2-72-270 cold Voc rises from 43.85 V to 49.38 V (beta_Voc -0.36%/C), capping a 600 V string at 12 panels (592.6 V).

How much roof area does an 8 kW array of US Solar USS-QCMI2-72-270 need?

An 8 kW DC system uses 30 US Solar USS-QCMI2-72-270 modules (8,100 W STC / 7,158 W PTC), covering roughly 628 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does US Solar USS-QCMI2-72-270 compare against Centrosolar America DP72 270?

US Solar USS-QCMI2-72-270 outputs 270.0 W STC (43.85 V Voc, rank #18,572 of 21,677), while Centrosolar America DP72 270 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.