US Solar USS-QCMI2-72-270 is a 270.0 W STC (238.6 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.89% efficiency, 43.85 V Voc at 25 C, and 49.38 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 238.6 W
- Voc @ 25C
- 43.85 V
- Efficiency
- 13.89%
How Does US Solar USS-QCMI2-72-270 Compare Against Peer CEC Listings?
Solar engineering breakdown for US Solar USS-QCMI2-72-270: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Measured at 270.0 W STC and 238.6 W PTC, US Solar USS-QCMI2-72-270 sits -115.0 W vs all-CEC median (below all-CEC median; higher than 12.9% of peers) among 21,677 listed modules. Power density reaches 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). Mid-range 43.85 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer Centrosolar America DP72 270 rates 270.0 W.
Where Does US Solar USS-QCMI2-72-270 Fall Across Listed CEC Models?
Distribution marker showing US Solar USS-QCMI2-72-270 (270.0 W) relative to the 385.0 W all-CEC solar panel median. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define US Solar USS-QCMI2-72-270?
Dataset percentiles tracking US Solar USS-QCMI2-72-270 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Do the Dataset Ranks Show for US Solar USS-QCMI2-72-270?
Benchmark highlights for US Solar USS-QCMI2-72-270 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.89% Aperture Efficiency
Power density 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.38 V at -10 C (592.6 V string) and 50.95 V at -20 C (11 max).
30 Panels = 8,100 W STC
Occupies 58.3 m2 (628 sq ft) producing 7,158 W PTC; NEC 690.8 OCPD floor is 12.62 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.85 * (1 + (-0.36/100) * (-10 - 25)) = 49.38 V | OCPD = 1.56 * 8.09 = 12.62 A
Inputs from CEC Modules.csv for US Solar USS-QCMI2-72-270: Voc=43.85 V, beta_Voc=-0.36%/C, Isc=8.09 A, STC=270.0 W, Area=1.944 m2.
Result: 12 panels max on 600 V (592.6 V); 30 panels for 8 kW (628 sq ft).
What Are the Published CEC Specifications for US Solar USS-QCMI2-72-270?
Official CEC datasheet figures for US Solar USS-QCMI2-72-270 (Multi-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 238.6 W (88.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.85 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.09 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.55 V / 7.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.89% (1.944 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many US Solar USS-QCMI2-72-270 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many US Solar USS-QCMI2-72-270 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 481 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 628 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 795 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This US Solar Series?
Consolidated US Solar wattage variants sharing the US Solar USS-QCMI2-72-270 mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| US Solar USS-QCMI2-72-265 | 265.0 W | 234.1 W | 43.5 V | 35.48 V | 13.63% |
| US Solar USS-QCMI2-72-270 | 270.0 W | 238.6 W | 43.85 V | 35.55 V | 13.89% |
How Many US Solar USS-QCMI2-72-270 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on US Solar USS-QCMI2-72-270 (49.38 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.95 V | 11 panels | 560.5 V | 19 panels |
| -10 C (14 F) | 49.38 V | 12 panels | 592.6 V | 20 panels |
| 0 C (32 F) | 47.8 V | 12 panels | 573.6 V | 20 panels |
| 25 C (77 F STC) | 43.85 V | 13 panels | 570.1 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI2-72-270?
Competing CEC solar panels closest to US Solar USS-QCMI2-72-270 in nameplate wattage and Voc, starting with Centrosolar America DP72 270.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP72 270 Centrosolar America |
270.0 W | Tie (0 W) | 43.85 V | 13.89% | 88.4% |
| Anhui Rinengzhongtian Semiconductor Development QJM270-72 Anhui Rinengzhongtian Semiconductor Development |
270.0 W | Tie (0 W) | 43.67 V | 13.92% | 89.6% |
| AXITEC AC-270P/156-72S AXITEC |
270.0 W | Tie (0 W) | 44.18 V | 13.94% | 89.9% |
| Advance Power API-M270 Advance Power |
270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI2-72-270?
Evaluate US Solar USS-QCMI2-72-270 (270.0 W STC, 43.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI2-72-270 reaches 50.95 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 628 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (628 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI2-72-270 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
US Solar USS-QCMI2-72-270 8 kW Residential Fit
Needs 30 modules (628 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DP72 270.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 238.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for US Solar USS-QCMI2-72-270 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many US Solar USS-QCMI2-72-270 panels fit on a 600 V winter solar string?
At -10 C (14 F), US Solar USS-QCMI2-72-270 cold Voc rises from 43.85 V to 49.38 V (beta_Voc -0.36%/C), capping a 600 V string at 12 panels (592.6 V).
How much roof area does an 8 kW array of US Solar USS-QCMI2-72-270 need?
An 8 kW DC system uses 30 US Solar USS-QCMI2-72-270 modules (8,100 W STC / 7,158 W PTC), covering roughly 628 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does US Solar USS-QCMI2-72-270 compare against Centrosolar America DP72 270?
US Solar USS-QCMI2-72-270 outputs 270.0 W STC (43.85 V Voc, rank #18,572 of 21,677), while Centrosolar America DP72 270 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)