US Solar USS-QCMI2-60-255 is a 255.0 W STC (226.2 W PTC) Multi-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.55% efficiency, 37.9 V Voc at 25 C, and 42.68 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 255.0 W
- PTC Wattage
- 226.2 W
- Voc @ 25C
- 37.9 V
- Efficiency
- 15.55%
How Does US Solar USS-QCMI2-60-255 Compare Against Peer CEC Listings?
Solar engineering breakdown for US Solar USS-QCMI2-60-255: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Measured at 255.0 W STC and 226.2 W PTC, US Solar USS-QCMI2-60-255 sits -130.0 W vs all-CEC median (below all-CEC median; higher than 9.2% of peers) among 21,677 listed modules. Power density reaches 155.5 W/m2 (4.36 percentage points below 19.91% CEC median). Lower 37.9 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer GCL System Integration Technology Co Ltd GCL-P6/60255 rates 255.0 W.
Where Does US Solar USS-QCMI2-60-255 Fall Across Listed CEC Models?
Distribution marker showing US Solar USS-QCMI2-60-255 (255.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define US Solar USS-QCMI2-60-255?
Dataset percentiles tracking US Solar USS-QCMI2-60-255 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Do the Dataset Ranks Show for US Solar USS-QCMI2-60-255?
Benchmark highlights for US Solar USS-QCMI2-60-255 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
255.0 W STC · Higher Than 9.2%
255.0 W STC (-130.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.55% Aperture Efficiency
Power density 155.5 W/m2 (4.36 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.68 V at -10 C (597.5 V string) and 44.04 V at -20 C (13 max).
32 Panels = 8,160 W STC
Occupies 52.5 m2 (565 sq ft) producing 7,238 W PTC; NEC 690.8 OCPD floor is 13.51 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.9 * (1 + (-0.36/100) * (-10 - 25)) = 42.68 V | OCPD = 1.56 * 8.66 = 13.51 A
Inputs from CEC Modules.csv for US Solar USS-QCMI2-60-255: Voc=37.9 V, beta_Voc=-0.36%/C, Isc=8.66 A, STC=255.0 W, Area=1.64 m2.
Result: 14 panels max on 600 V (597.5 V); 32 panels for 8 kW (565 sq ft).
What Are the Published CEC Specifications for US Solar USS-QCMI2-60-255?
Official CEC datasheet figures for US Solar USS-QCMI2-60-255 (Multi-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 255.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 226.2 W (88.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.25 V / 8.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.55% (1.64 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many US Solar USS-QCMI2-60-255 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many US Solar USS-QCMI2-60-255 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.12 kW | 424 sq ft | $1,532 | $2,590 |
| 8 kW Class | 32 | 8.16 kW | 565 sq ft | $2,042 | $3,454 |
| 10 kW Class | 40 | 10.2 kW | 706 sq ft | $2,553 | $4,317 |
Which Sibling Wattage & Trim Variants Belong to This US Solar Series?
Consolidated US Solar wattage variants sharing the US Solar USS-QCMI2-60-255 mechanical and cell layout. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| US Solar USS-QCMI2-60-250 | 250.0 W | 225.3 W | 37.65 V | 30.83 V | 15.25% |
| US Solar USS-QCMI2-60-255 | 255.0 W | 226.2 W | 37.9 V | 31.25 V | 15.55% |
How Many US Solar USS-QCMI2-60-255 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on US Solar USS-QCMI2-60-255 (42.68 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.04 V | 13 panels | 572.5 V | 22 panels |
| -10 C (14 F) | 42.68 V | 14 panels | 597.5 V | 23 panels |
| 0 C (32 F) | 41.31 V | 14 panels | 578.3 V | 24 panels |
| 25 C (77 F STC) | 37.9 V | 15 panels | 568.5 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI2-60-255?
Competing CEC solar panels closest to US Solar USS-QCMI2-60-255 in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-P6/60255.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-P6/60255 GCL System Integration Technology Co Ltd |
255.0 W | Tie (0 W) | 37.7 V | 15.67% | 90.4% |
| Advance Power API-M255 Advance Power |
255.0 W | Tie (0 W) | 37.68 V | 15.57% | 89.5% |
| Eoplly New Energy Technology EP156P/60-255S AC Eoplly New Energy Technology |
255.0 W | Tie (0 W) | 37.68 V | 15.6% | 89.9% |
| Changzhou Nesl Solartech DJ-255D/C-ST15 Changzhou Nesl Solartech |
255.0 W | Tie (0 W) | 38.19 V | 15.61% | 90.4% |
What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI2-60-255?
Evaluate US Solar USS-QCMI2-60-255 (255.0 W STC, 37.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI2-60-255 reaches 44.04 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 565 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (565 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI2-60-255 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
US Solar USS-QCMI2-60-255 8 kW Residential Fit
Needs 32 modules (565 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/60255.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 226.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for US Solar USS-QCMI2-60-255 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many US Solar USS-QCMI2-60-255 panels fit on a 600 V winter solar string?
At -10 C (14 F), US Solar USS-QCMI2-60-255 cold Voc rises from 37.9 V to 42.68 V (beta_Voc -0.36%/C), capping a 600 V string at 14 panels (597.5 V).
How much roof area does an 8 kW array of US Solar USS-QCMI2-60-255 need?
An 8 kW DC system uses 32 US Solar USS-QCMI2-60-255 modules (8,160 W STC / 7,238 W PTC), covering roughly 565 sq ft and saving ~$2,042/yr at 18.54 c/kWh.
How does US Solar USS-QCMI2-60-255 compare against GCL System Integration Technology Co Ltd GCL-P6/60255?
US Solar USS-QCMI2-60-255 outputs 255.0 W STC (37.9 V Voc, rank #19,421 of 21,677), while GCL System Integration Technology Co Ltd GCL-P6/60255 delivers 255.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)