Skip to main content
WireAndSun
Calculators
CEC PV Module

US Solar USS-QCMI2-60-255 — CEC Solar Module Specifications

Manufacturer: US Solar Registry: CEC Verified Engineering Specification

US Solar USS-QCMI2-60-255 is a 255.0 W STC (226.2 W PTC) Multi-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.55% efficiency, 37.9 V Voc at 25 C, and 42.68 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
255.0 W
PTC Wattage
226.2 W
Voc @ 25C
37.9 V
Efficiency
15.55%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does US Solar USS-QCMI2-60-255 Compare Against Peer CEC Listings?

Solar engineering breakdown for US Solar USS-QCMI2-60-255: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Measured at 255.0 W STC and 226.2 W PTC, US Solar USS-QCMI2-60-255 sits -130.0 W vs all-CEC median (below all-CEC median; higher than 9.2% of peers) among 21,677 listed modules. Power density reaches 155.5 W/m2 (4.36 percentage points below 19.91% CEC median). Lower 37.9 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer GCL System Integration Technology Co Ltd GCL-P6/60255 rates 255.0 W.

Where Does US Solar USS-QCMI2-60-255 Fall Across Listed CEC Models?

Distribution marker showing US Solar USS-QCMI2-60-255 (255.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where US Solar USS-QCMI2-60-255 (255.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUS Solar USS-QCMI2: 255.0 W

What Dataset Percentiles Define US Solar USS-QCMI2-60-255?

Dataset percentiles tracking US Solar USS-QCMI2-60-255 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

US Solar USS-QCMI2-60-255 Engineering BenchmarksPercentile comparison of US Solar USS-QCMI2-60-255 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage255.0 WPTC/STC Retention88.7%Module Efficiency15.55%

What Do the Dataset Ranks Show for US Solar USS-QCMI2-60-255?

Benchmark highlights for US Solar USS-QCMI2-60-255 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #19,421 / 21,677

255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,853

15.55% Aperture Efficiency

Power density 155.5 W/m2 (4.36 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.68 V at -10 C (597.5 V string) and 44.04 V at -20 C (13 max).

8 kW Reference Array

32 Panels = 8,160 W STC

Occupies 52.5 m2 (565 sq ft) producing 7,238 W PTC; NEC 690.8 OCPD floor is 13.51 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.9 * (1 + (-0.36/100) * (-10 - 25)) = 42.68 V | OCPD = 1.56 * 8.66 = 13.51 A

Inputs from CEC Modules.csv for US Solar USS-QCMI2-60-255: Voc=37.9 V, beta_Voc=-0.36%/C, Isc=8.66 A, STC=255.0 W, Area=1.64 m2.

Result: 14 panels max on 600 V (597.5 V); 32 panels for 8 kW (565 sq ft).

What Are the Published CEC Specifications for US Solar USS-QCMI2-60-255?

Official CEC datasheet figures for US Solar USS-QCMI2-60-255 (Multi-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMI2-60-255.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 255.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 226.2 W (88.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.66 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.25 V / 8.16 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.55% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many US Solar USS-QCMI2-60-255 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many US Solar USS-QCMI2-60-255 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.12 kW 424 sq ft $1,532 $2,590
8 kW Class 32 8.16 kW 565 sq ft $2,042 $3,454
10 kW Class 40 10.2 kW 706 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

Consolidated US Solar wattage variants sharing the US Solar USS-QCMI2-60-255 mechanical and cell layout. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the US Solar USS-QCMI2-60-255 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
US Solar USS-QCMI2-60-250 250.0 W 225.3 W 37.65 V 30.83 V 15.25%
US Solar USS-QCMI2-60-255 255.0 W 226.2 W 37.9 V 31.25 V 15.55%

How Many US Solar USS-QCMI2-60-255 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on US Solar USS-QCMI2-60-255 (42.68 V at 14 F).

Computed from Voc=37.9V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.04 V 13 panels 572.5 V 22 panels
-10 C (14 F) 42.68 V 14 panels 597.5 V 23 panels
0 C (32 F) 41.31 V 14 panels 578.3 V 24 panels
25 C (77 F STC) 37.9 V 15 panels 568.5 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI2-60-255?

Competing CEC solar panels closest to US Solar USS-QCMI2-60-255 in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-P6/60255.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/60255
GCL System Integration Technology Co Ltd
255.0 W Tie (0 W) 37.7 V 15.67% 90.4%
Advance Power API-M255
Advance Power
255.0 W Tie (0 W) 37.68 V 15.57% 89.5%
Eoplly New Energy Technology EP156P/60-255S AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.68 V 15.6% 89.9%
Changzhou Nesl Solartech DJ-255D/C-ST15
Changzhou Nesl Solartech
255.0 W Tie (0 W) 38.19 V 15.61% 90.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI2-60-255?

Evaluate US Solar USS-QCMI2-60-255 (255.0 W STC, 37.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI2-60-255 reaches 44.04 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 565 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (565 sq ft).
  • 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI2-60-255 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

US Solar USS-QCMI2-60-255 8 kW Residential Fit

Needs 32 modules (565 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/60255.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 226.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMI2-60-255 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many US Solar USS-QCMI2-60-255 panels fit on a 600 V winter solar string?

At -10 C (14 F), US Solar USS-QCMI2-60-255 cold Voc rises from 37.9 V to 42.68 V (beta_Voc -0.36%/C), capping a 600 V string at 14 panels (597.5 V).

How much roof area does an 8 kW array of US Solar USS-QCMI2-60-255 need?

An 8 kW DC system uses 32 US Solar USS-QCMI2-60-255 modules (8,160 W STC / 7,238 W PTC), covering roughly 565 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does US Solar USS-QCMI2-60-255 compare against GCL System Integration Technology Co Ltd GCL-P6/60255?

US Solar USS-QCMI2-60-255 outputs 255.0 W STC (37.9 V Voc, rank #19,421 of 21,677), while GCL System Integration Technology Co Ltd GCL-P6/60255 delivers 255.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.