Thornova Solar TS-SB54(400) is a 400.0 W STC (376.9 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.62% efficiency, 37.18 V Voc at 25 C, and 40.26 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 400.0 W
- PTC Wattage
- 376.9 W
- Voc @ 25C
- 37.18 V
- Efficiency
- 20.62%
How Does Thornova Solar TS-SB54(400) Compare Against Peer CEC Listings?
Solar engineering breakdown for Thornova Solar TS-SB54(400): PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Thornova Solar and peers, Thornova Solar TS-SB54(400) stands 10.0 W below the 410.0 W Mono-c-Si median and strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,502-$2,503/yr in baseline US bill offset. Lower 37.18 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Thornova Solar TS-SB54(400) Fall Across Listed CEC Models?
Distribution marker showing Thornova Solar TS-SB54(400) (400.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Thornova Solar TS-SB54(400)?
Dataset percentiles tracking Thornova Solar TS-SB54(400) power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Thornova Solar TS-SB54(400)?
Benchmark highlights for Thornova Solar TS-SB54(400) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 45.5% STC Output
400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.62% Aperture Efficiency
Power density 206.2 W/m2 (0.71 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.26 V at -10 C (563.6 V string) and 41.15 V at -20 C (14 max).
20 Panels = 8,000 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,538 W PTC; NEC 690.8 OCPD floor is 20.89 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.18 * (1 + (-0.237/100) * (-10 - 25)) = 40.26 V | OCPD = 1.56 * 13.39 = 20.89 A
Inputs from CEC Modules.csv for Thornova Solar TS-SB54(400): Voc=37.18 V, beta_Voc=-0.237%/C, Isc=13.39 A, STC=400.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (563.6 V); 20 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-SB54(400)?
Official CEC datasheet figures for Thornova Solar TS-SB54(400) (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 376.9 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.39 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.42 V / 12.74 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.237 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.62% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Thornova Solar TS-SB54(400) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Thornova Solar TS-SB54(400) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.0 kW | 313 sq ft | $1,502 | $2,539 |
| 8 kW Class | 20 | 8.0 kW | 418 sq ft | $2,002 | $3,386 |
| 10 kW Class | 25 | 10.0 kW | 522 sq ft | $2,503 | $4,232 |
How Many Thornova Solar TS-SB54(400) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-SB54(400) (40.26 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.15 V | 14 panels | 576.1 V | 24 panels |
| -10 C (14 F) | 40.26 V | 14 panels | 563.6 V | 24 panels |
| 0 C (32 F) | 39.38 V | 15 panels | 590.7 V | 25 panels |
| 25 C (77 F STC) | 37.18 V | 16 panels | 594.9 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-SB54(400)?
Competing CEC solar panels closest to Thornova Solar TS-SB54(400) in nameplate wattage and Voc, starting with CertainTeed CTM10400HC11-09.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CTM10400HC11-09 CertainTeed |
400.0 W | Tie (0 W) | 37.2 V | 20.62% | 93.9% |
| Apollo Renewables Inc Apollo-M754BH-400BB Apollo Renewables Inc |
400.0 W | Tie (0 W) | 37.07 V | 20.62% | 93.7% |
| CertainTeed CTM10400HC11-06 CertainTeed |
400.0 W | Tie (0 W) | 37.04 V | 20.51% | 93.7% |
| Changzhou EGing Photovoltaic Technology Co Ltd EG-405M54-HLV Changzhou EGing Photovoltaic Technology Co Ltd |
405.0 W | +5.0 W | 37.2 V | 20.77% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-SB54(400)?
Evaluate Thornova Solar TS-SB54(400) (400.0 W STC, 37.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-SB54(400) reaches 41.15 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-SB54(400) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-SB54(400) 8 kW Residential Fit
Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CertainTeed CTM10400HC11-09.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 376.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-SB54(400) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-SB54(400)?
Multiplying Thornova Solar TS-SB54(400)'s 13.39 A short-circuit current by 1.56 equals 20.89 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-SB54(400) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.26 V cold Voc at 14 F and handles 13.39 A Isc; string inverters cap Thornova Solar TS-SB54(400) at 14 panels on 600 V.
Is Thornova Solar TS-SB54(400) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-SB54(400) rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)