CertainTeed CTM10400HC11-09 is a 400.0 W STC (375.6 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.62% efficiency, 37.2 V Voc at 25 C, and 40.4 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 400.0 W
- PTC Wattage
- 375.6 W
- Voc @ 25C
- 37.2 V
- Efficiency
- 20.62%
How Does CertainTeed CTM10400HC11-09 Compare Against Peer CEC Listings?
How CertainTeed CertainTeed CTM10400HC11-09 handles rooftop heat (375.6 W PTC), 8 kW sizing, and cold winter string voltage.
CertainTeed builds the CertainTeed CTM10400HC11-09 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 206.2 W/m2 (0.71 percentage points above 19.91% CEC median). Compared against Apollo Renewables Inc Apollo-M754BH-400BB (400.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Lower 37.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.12 A overcurrent floor served by a 25 A breaker.
Where Does CertainTeed CTM10400HC11-09 Fall Across Listed CEC Models?
Where CertainTeed CTM10400HC11-09 (400.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define CertainTeed CTM10400HC11-09?
Percentile placement of CertainTeed CTM10400HC11-09 across power density (206.2 W/m2), thermal retention, and nameplate STC wattage. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for CertainTeed CTM10400HC11-09?
Four critical engineering numbers homeowners and solar installers check first when reviewing CertainTeed CTM10400HC11-09 specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
Top 45.5% STC Output
400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.62% Aperture Efficiency
Power density 206.2 W/m2 (0.71 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.4 V at -10 C (565.6 V string) and 41.32 V at -20 C (14 max).
20 Panels = 8,000 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,512 W PTC; NEC 690.8 OCPD floor is 21.12 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.2 * (1 + (-0.246/100) * (-10 - 25)) = 40.4 V | OCPD = 1.56 * 13.54 = 21.12 A
Inputs from CEC Modules.csv for CertainTeed CTM10400HC11-09: Voc=37.2 V, beta_Voc=-0.246%/C, Isc=13.54 A, STC=400.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (565.6 V); 20 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for CertainTeed CTM10400HC11-09?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CertainTeed CTM10400HC11-09. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 375.6 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.3 V / 12.8 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.246 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.62% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 108 cells (Mono-c-Si) | Monofacial backsheet |
How Many CertainTeed CTM10400HC11-09 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CertainTeed CTM10400HC11-09 (400.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.0 kW | 313 sq ft | $1,502 | $2,539 |
| 8 kW Class | 20 | 8.0 kW | 418 sq ft | $2,002 | $3,386 |
| 10 kW Class | 25 | 10.0 kW | 522 sq ft | $2,503 | $4,232 |
How Many CertainTeed CTM10400HC11-09 Modules Fit in a Cold-Weather String?
Maximum series module counts for CertainTeed CTM10400HC11-09 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.32 V | 14 panels | 578.5 V | 24 panels |
| -10 C (14 F) | 40.4 V | 14 panels | 565.6 V | 24 panels |
| 0 C (32 F) | 39.49 V | 15 panels | 592.4 V | 25 panels |
| 25 C (77 F STC) | 37.2 V | 16 panels | 595.2 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to CertainTeed CTM10400HC11-09?
Alternative CEC solar modules from competing brands near CertainTeed CTM10400HC11-09 (400.0 W), including Apollo Renewables Inc Apollo-M754BH-400BB. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Apollo Renewables Inc Apollo-M754BH-400BB Apollo Renewables Inc |
400.0 W | Tie (0 W) | 37.07 V | 20.62% | 93.7% |
| Changzhou EGing Photovoltaic Technology Co Ltd EG-405M54-HLV Changzhou EGing Photovoltaic Technology Co Ltd |
405.0 W | +5.0 W | 37.2 V | 20.77% | 93.8% |
| AMPS Solar AMPS-405P-54BB AMPS Solar |
405.0 W | +5.0 W | 37.25 V | 20.88% | 94.2% |
| Convalt Manufacturing LLC CVLT405-108M-BB Convalt Manufacturing LLC |
405.0 W | +5.0 W | 37.36 V | 20.88% | 92.0% |
What Are the Design Limits and Best-Fit Uses for CertainTeed CTM10400HC11-09?
Evaluate CertainTeed CTM10400HC11-09 (400.0 W STC, 37.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed CTM10400HC11-09 reaches 41.32 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of CertainTeed CTM10400HC11-09 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CertainTeed CTM10400HC11-09 8 kW Residential Fit
Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Apollo Renewables Inc Apollo-M754BH-400BB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 375.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CertainTeed CTM10400HC11-09 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What fuse or breaker size does NEC 690.8 require for CertainTeed CTM10400HC11-09?
Multiplying CertainTeed CTM10400HC11-09's 13.54 A short-circuit current by 1.56 equals 21.12 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for CertainTeed CTM10400HC11-09 before finalizing component orders.
Can CertainTeed CTM10400HC11-09 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.4 V cold Voc at 14 F and handles 13.54 A Isc; string inverters cap CertainTeed CTM10400HC11-09 at 14 panels on 600 V.
Is CertainTeed CTM10400HC11-09 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CertainTeed CTM10400HC11-09 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)