CertainTeed CTM10400HC11-06 is a 400.0 W STC (374.9 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.51% efficiency, 37.04 V Voc at 25 C, and 40.57 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 400.0 W
- PTC Wattage
- 374.9 W
- Voc @ 25C
- 37.04 V
- Efficiency
- 20.51%
How Does CertainTeed CTM10400HC11-06 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for CertainTeed CTM10400HC11-06 (Mono-c-Si) residential solar systems. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
CertainTeed CTM10400HC11-06 delivers 205.1 W/m2 (0.60 percentage points above 19.91% CEC median) and strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 41.57 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with Apollo Renewables Inc Apollo-M754BH-400BB (400.0 W).
Where Does CertainTeed CTM10400HC11-06 Fall Across Listed CEC Models?
Comparison of CertainTeed CTM10400HC11-06 (400.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Dataset Percentiles Define CertainTeed CTM10400HC11-06?
Relative ranking of CertainTeed CTM10400HC11-06 across nameplate watts, 93.7% PTC thermal ratio, and module aperture efficiency. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Do the Dataset Ranks Show for CertainTeed CTM10400HC11-06?
Summary of CertainTeed CTM10400HC11-06 output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.
Top 45.5% STC Output
400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.51% Aperture Efficiency
Power density 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.57 V at -10 C (568.0 V string) and 41.57 V at -20 C (14 max).
20 Panels = 8,000 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,498 W PTC; NEC 690.8 OCPD floor is 21.51 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.04 * (1 + (-0.272/100) * (-10 - 25)) = 40.57 V | OCPD = 1.56 * 13.79 = 21.51 A
Inputs from CEC Modules.csv for CertainTeed CTM10400HC11-06: Voc=37.04 V, beta_Voc=-0.272%/C, Isc=13.79 A, STC=400.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (568.0 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for CertainTeed CTM10400HC11-06?
Complete CEC test sheet for CertainTeed CTM10400HC11-06 including Isc (13.79 A), Voc (37.04 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 374.9 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.04 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.01 V / 12.9 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.272 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.51% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many CertainTeed CTM10400HC11-06 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using CertainTeed CTM10400HC11-06.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.0 kW | 315 sq ft | $1,502 | $2,539 |
| 8 kW Class | 20 | 8.0 kW | 420 sq ft | $2,002 | $3,386 |
| 10 kW Class | 25 | 10.0 kW | 525 sq ft | $2,503 | $4,232 |
How Many CertainTeed CTM10400HC11-06 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for CertainTeed CTM10400HC11-06 (37.04 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.57 V | 14 panels | 582.0 V | 24 panels |
| -10 C (14 F) | 40.57 V | 14 panels | 568.0 V | 24 panels |
| 0 C (32 F) | 39.56 V | 15 panels | 593.4 V | 25 panels |
| 25 C (77 F STC) | 37.04 V | 16 panels | 592.6 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to CertainTeed CTM10400HC11-06?
Four comparable CEC modules such as Apollo Renewables Inc Apollo-M754BH-400BB (400.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Apollo Renewables Inc Apollo-M754BH-400BB Apollo Renewables Inc |
400.0 W | Tie (0 W) | 37.07 V | 20.62% | 93.7% |
| CSI Solar Co Ltd CS6R-405MS-HL {Blk} CSI Solar Co Ltd |
405.0 W | +5.0 W | 37.0 V | 20.77% | 94.2% |
| Changzhou EGing Photovoltaic Technology Co Ltd EG-405M54-HLV Changzhou EGing Photovoltaic Technology Co Ltd |
405.0 W | +5.0 W | 37.2 V | 20.77% | 93.8% |
| AMPS Solar AMPS-405P-54BB AMPS Solar |
405.0 W | +5.0 W | 37.25 V | 20.88% | 94.2% |
What Are the Design Limits and Best-Fit Uses for CertainTeed CTM10400HC11-06?
Evaluate CertainTeed CTM10400HC11-06 (400.0 W STC, 37.04 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed CTM10400HC11-06 reaches 41.57 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of CertainTeed CTM10400HC11-06 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CertainTeed CTM10400HC11-06 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Apollo Renewables Inc Apollo-M754BH-400BB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 374.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CertainTeed CTM10400HC11-06 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
How many CertainTeed CTM10400HC11-06 panels fit on a 600 V winter solar string?
At -10 C (14 F), CertainTeed CTM10400HC11-06 cold Voc rises from 37.04 V to 40.57 V (beta_Voc -0.272%/C), capping a 600 V string at 14 panels (568.0 V).
How much roof area does an 8 kW array of CertainTeed CTM10400HC11-06 need?
An 8 kW DC system uses 20 CertainTeed CTM10400HC11-06 modules (8,000 W STC / 7,498 W PTC), covering roughly 420 sq ft and saving ~$2,002/yr at 18.54 c/kWh.
How does CertainTeed CTM10400HC11-06 compare against Apollo Renewables Inc Apollo-M754BH-400BB?
CertainTeed CTM10400HC11-06 outputs 400.0 W STC (37.04 V Voc, rank #9,407 of 21,677), while Apollo Renewables Inc Apollo-M754BH-400BB delivers 400.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)