Thornova Solar TS-BGT60(470) is a 470.0 W STC (446.4 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 21.96% efficiency, 43.16 V Voc at 25 C, and 46.57 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 470.0 W
- PTC Wattage
- 446.4 W
- Voc @ 25C
- 43.16 V
- Efficiency
- 21.96%
How Does Thornova Solar TS-BGT60(470) Compare Against Peer CEC Listings?
Solar engineering breakdown for Thornova Solar TS-BGT60(470): PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 470.0 W STC and 446.4 W PTC, Thornova Solar TS-BGT60(470) sits +85.0 W vs all-CEC median (top 23.4%; higher than 76.6% of peers) among 21,677 listed modules. Power density reaches 219.6 W/m2 (2.05 percentage points above 19.91% CEC median). Mid-range 43.16 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 21 panels in series. Alternative peer Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 rates 475.0 W.
Where Does Thornova Solar TS-BGT60(470) Fall Across Listed CEC Models?
Distribution marker showing Thornova Solar TS-BGT60(470) (470.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Thornova Solar TS-BGT60(470)?
Dataset percentiles tracking Thornova Solar TS-BGT60(470) power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Thornova Solar TS-BGT60(470)?
Benchmark highlights for Thornova Solar TS-BGT60(470) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 23.4% STC Output
470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.96% Aperture Efficiency
Power density 219.6 W/m2 (2.05 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 46.57 V at -10 C (558.8 V string) and 47.55 V at -20 C (12 max).
18 Panels = 8,460 W STC
Occupies 38.5 m2 (415 sq ft) producing 8,035 W PTC; NEC 690.8 OCPD floor is 21.23 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.16 * (1 + (-0.226/100) * (-10 - 25)) = 46.57 V | OCPD = 1.56 * 13.61 = 21.23 A
Inputs from CEC Modules.csv for Thornova Solar TS-BGT60(470): Voc=43.16 V, beta_Voc=-0.226%/C, Isc=13.61 A, STC=470.0 W, Area=2.14 m2.
Result: 12 panels max on 600 V (558.8 V); 18 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BGT60(470)?
Official CEC datasheet figures for Thornova Solar TS-BGT60(470) (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 470.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 446.4 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.16 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.19 V / 12.99 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.226 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.96% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BGT60(470) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Thornova Solar TS-BGT60(470) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.11 kW | 299 sq ft | $1,529 | $2,586 |
| 8 kW Class | 18 | 8.46 kW | 415 sq ft | $2,117 | $3,580 |
| 10 kW Class | 22 | 10.34 kW | 507 sq ft | $2,588 | $4,376 |
How Many Thornova Solar TS-BGT60(470) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BGT60(470) (46.57 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 47.55 V | 12 panels | 570.6 V | 21 panels |
| -10 C (14 F) | 46.57 V | 12 panels | 558.8 V | 21 panels |
| 0 C (32 F) | 45.6 V | 13 panels | 592.8 V | 21 panels |
| 25 C (77 F STC) | 43.16 V | 13 panels | 561.1 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT60(470)?
Competing CEC solar panels closest to Thornova Solar TS-BGT60(470) in nameplate wattage and Voc, starting with Elin Energy (Sirius PV) ELNSM60M-HC-BF-475.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 Elin Energy (Sirius PV) |
475.0 W | +5.0 W | 41.82 V | 22.09% | 94.5% |
| Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF Boviet Solar Technology Co Ltd |
460.0 W | -10.0 W | 43.44 V | 21.3% | 94.9% |
| Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG Boviet Solar Technology Co Ltd |
460.0 W | -10.0 W | 42.49 V | 21.9% | 94.2% |
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 Elin Energy (Sirius PV) |
460.0 W | -10.0 W | 41.52 V | 21.4% | 94.4% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT60(470)?
Evaluate Thornova Solar TS-BGT60(470) (470.0 W STC, 43.16 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT60(470) reaches 47.55 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT60(470) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BGT60(470) 8 kW Residential Fit
Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,117/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM60M-HC-BF-475.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 446.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BGT60(470) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Thornova Solar TS-BGT60(470) panels fit on a 600 V winter solar string?
At -10 C (14 F), Thornova Solar TS-BGT60(470) cold Voc rises from 43.16 V to 46.57 V (beta_Voc -0.226%/C), capping a 600 V string at 12 panels (558.8 V).
How much roof area does an 8 kW array of Thornova Solar TS-BGT60(470) need?
An 8 kW DC system uses 18 Thornova Solar TS-BGT60(470) modules (8,460 W STC / 8,035 W PTC), covering roughly 415 sq ft and saving ~$2,117/yr at 18.54 c/kWh.
How does Thornova Solar TS-BGT60(470) compare against Elin Energy (Sirius PV) ELNSM60M-HC-BF-475?
Thornova Solar TS-BGT60(470) outputs 470.0 W STC (43.16 V Voc, rank #4,967 of 21,677), while Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 delivers 475.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)