Thornova Solar TS-BG60(470) is a 470.0 W STC (444.8 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 21.96% efficiency, 42.06 V Voc at 25 C, and 45.49 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 470.0 W
- PTC Wattage
- 444.8 W
- Voc @ 25C
- 42.06 V
- Efficiency
- 21.96%
How Does Thornova Solar TS-BG60(470) Compare Against Peer CEC Listings?
Solar engineering breakdown for Thornova Solar TS-BG60(470): PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Thornova Solar and peers, Thornova Solar TS-BG60(470) stands 60.0 W above the 410.0 W Mono-c-Si median and strong 94.6% PTC-to-STC heat retention (#2,348 of 21,677). Sizing 6 kW (13 panels) to 10 kW (22 panels) yields $1,529-$2,588/yr in baseline US bill offset. Mid-range 42.06 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does Thornova Solar TS-BG60(470) Fall Across Listed CEC Models?
Distribution marker showing Thornova Solar TS-BG60(470) (470.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Thornova Solar TS-BG60(470)?
Dataset percentiles tracking Thornova Solar TS-BG60(470) power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Thornova Solar TS-BG60(470)?
Benchmark highlights for Thornova Solar TS-BG60(470) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 23.4% STC Output
470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.96% Aperture Efficiency
Power density 219.6 W/m2 (2.05 percentage points above 19.91% CEC median). PTC/STC ratio: 94.6% (rank #2,348).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.49 V at -10 C (591.4 V string) and 46.47 V at -20 C (12 max).
18 Panels = 8,460 W STC
Occupies 38.5 m2 (415 sq ft) producing 8,006 W PTC; NEC 690.8 OCPD floor is 21.57 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 42.06 * (1 + (-0.233/100) * (-10 - 25)) = 45.49 V | OCPD = 1.56 * 13.83 = 21.57 A
Inputs from CEC Modules.csv for Thornova Solar TS-BG60(470): Voc=42.06 V, beta_Voc=-0.233%/C, Isc=13.83 A, STC=470.0 W, Area=2.14 m2.
Result: 13 panels max on 600 V (591.4 V); 18 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BG60(470)?
Official CEC datasheet figures for Thornova Solar TS-BG60(470) (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 470.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 444.8 W (94.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 42.06 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.15 V / 13.37 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.233 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.96% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BG60(470) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Thornova Solar TS-BG60(470) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.11 kW | 299 sq ft | $1,529 | $2,586 |
| 8 kW Class | 18 | 8.46 kW | 415 sq ft | $2,117 | $3,580 |
| 10 kW Class | 22 | 10.34 kW | 507 sq ft | $2,588 | $4,376 |
How Many Thornova Solar TS-BG60(470) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BG60(470) (45.49 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.47 V | 12 panels | 557.6 V | 21 panels |
| -10 C (14 F) | 45.49 V | 13 panels | 591.4 V | 21 panels |
| 0 C (32 F) | 44.51 V | 13 panels | 578.6 V | 22 panels |
| 25 C (77 F STC) | 42.06 V | 14 panels | 588.8 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BG60(470)?
Competing CEC solar panels closest to Thornova Solar TS-BG60(470) in nameplate wattage and Voc, starting with Elin Energy (Sirius PV) ELNSM60M-HC-BF-475.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 Elin Energy (Sirius PV) |
475.0 W | +5.0 W | 41.82 V | 22.09% | 94.5% |
| Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG Boviet Solar Technology Co Ltd |
460.0 W | -10.0 W | 42.49 V | 21.9% | 94.2% |
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 Elin Energy (Sirius PV) |
460.0 W | -10.0 W | 41.52 V | 21.4% | 94.4% |
| Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF Boviet Solar Technology Co Ltd |
460.0 W | -10.0 W | 43.44 V | 21.3% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BG60(470)?
Evaluate Thornova Solar TS-BG60(470) (470.0 W STC, 42.06 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BG60(470) reaches 46.47 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BG60(470) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BG60(470) 8 kW Residential Fit
Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,117/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM60M-HC-BF-475.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 444.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BG60(470) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BG60(470)?
Multiplying Thornova Solar TS-BG60(470)'s 13.83 A short-circuit current by 1.56 equals 21.57 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-BG60(470) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.49 V cold Voc at 14 F and handles 13.83 A Isc; string inverters cap Thornova Solar TS-BG60(470) at 13 panels on 600 V.
Is Thornova Solar TS-BG60(470) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BG60(470) rely on utility bill offset (~$2,117/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)