Thornova Solar TS-BG60(465) is a 465.0 W STC (439.9 W PTC) Mono-c-Si solar module ranking #5,072 of 21,677 CEC listings (top 24.0%; higher than 76.0% of peers). It delivers 21.73% efficiency, 41.92 V Voc at 25 C, and 45.34 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 465.0 W
- PTC Wattage
- 439.9 W
- Voc @ 25C
- 41.92 V
- Efficiency
- 21.73%
How Does Thornova Solar TS-BG60(465) Compare Against Peer CEC Listings?
Solar engineering breakdown for Thornova Solar TS-BG60(465): PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 465.0 W STC and 439.9 W PTC, Thornova Solar TS-BG60(465) sits +80.0 W vs all-CEC median (top 24.0%; higher than 76.0% of peers) among 21,677 listed modules. Power density reaches 217.3 W/m2 (1.82 percentage points above 19.91% CEC median). Mid-range 41.92 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 rates 460.0 W.
Where Does Thornova Solar TS-BG60(465) Fall Across Listed CEC Models?
Distribution marker showing Thornova Solar TS-BG60(465) (465.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Thornova Solar TS-BG60(465)?
Dataset percentiles tracking Thornova Solar TS-BG60(465) power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Thornova Solar TS-BG60(465)?
Benchmark highlights for Thornova Solar TS-BG60(465) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 24.0% STC Output
465.0 W STC (+80.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.73% Aperture Efficiency
Power density 217.3 W/m2 (1.82 percentage points above 19.91% CEC median). PTC/STC ratio: 94.6% (rank #2,348).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.34 V at -10 C (589.4 V string) and 46.32 V at -20 C (12 max).
18 Panels = 8,370 W STC
Occupies 38.5 m2 (415 sq ft) producing 7,918 W PTC; NEC 690.8 OCPD floor is 21.42 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.92 * (1 + (-0.233/100) * (-10 - 25)) = 45.34 V | OCPD = 1.56 * 13.73 = 21.42 A
Inputs from CEC Modules.csv for Thornova Solar TS-BG60(465): Voc=41.92 V, beta_Voc=-0.233%/C, Isc=13.73 A, STC=465.0 W, Area=2.14 m2.
Result: 13 panels max on 600 V (589.4 V); 18 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BG60(465)?
Official CEC datasheet figures for Thornova Solar TS-BG60(465) (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 465.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 439.9 W (94.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.92 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.02 V / 13.28 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.233 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.73% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BG60(465) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Thornova Solar TS-BG60(465) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.04 kW | 299 sq ft | $1,512 | $2,556 |
| 8 kW Class | 18 | 8.37 kW | 415 sq ft | $2,095 | $3,542 |
| 10 kW Class | 22 | 10.23 kW | 507 sq ft | $2,560 | $4,330 |
How Many Thornova Solar TS-BG60(465) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BG60(465) (45.34 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.32 V | 12 panels | 555.8 V | 21 panels |
| -10 C (14 F) | 45.34 V | 13 panels | 589.4 V | 22 panels |
| 0 C (32 F) | 44.36 V | 13 panels | 576.7 V | 22 panels |
| 25 C (77 F STC) | 41.92 V | 14 panels | 586.9 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BG60(465)?
Competing CEC solar panels closest to Thornova Solar TS-BG60(465) in nameplate wattage and Voc, starting with Elin Energy (Sirius PV) ELNSM60M-HC-BF-460.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 Elin Energy (Sirius PV) |
460.0 W | -5.0 W | 41.52 V | 21.4% | 94.4% |
| Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG Boviet Solar Technology Co Ltd |
460.0 W | -5.0 W | 42.49 V | 21.9% | 94.2% |
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 Elin Energy (Sirius PV) |
475.0 W | +10.0 W | 41.82 V | 22.09% | 94.5% |
| Aptos Solar Technology LLC DNA-120-BF10-455W-USAptos2 Aptos Solar Technology LLC |
455.0 W | -10.0 W | 41.7 V | 21.26% | 94.4% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BG60(465)?
Evaluate Thornova Solar TS-BG60(465) (465.0 W STC, 41.92 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BG60(465) reaches 46.32 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BG60(465) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BG60(465) 8 kW Residential Fit
Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,095/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM60M-HC-BF-460.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 439.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BG60(465) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Thornova Solar TS-BG60(465) panels fit on a 600 V winter solar string?
At -10 C (14 F), Thornova Solar TS-BG60(465) cold Voc rises from 41.92 V to 45.34 V (beta_Voc -0.233%/C), capping a 600 V string at 13 panels (589.4 V).
How much roof area does an 8 kW array of Thornova Solar TS-BG60(465) need?
An 8 kW DC system uses 18 Thornova Solar TS-BG60(465) modules (8,370 W STC / 7,918 W PTC), covering roughly 415 sq ft and saving ~$2,095/yr at 18.54 c/kWh.
How does Thornova Solar TS-BG60(465) compare against Elin Energy (Sirius PV) ELNSM60M-HC-BF-460?
Thornova Solar TS-BG60(465) outputs 465.0 W STC (41.92 V Voc, rank #5,072 of 21,677), while Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)