Thornova Solar TS-BBT60(495) is a 495.0 W STC (470.9 W PTC) Mono-c-Si solar module ranking #4,591 of 21,677 CEC listings (top 21.5%; higher than 78.5% of peers). It delivers 23.13% efficiency, 43.57 V Voc at 25 C, and 47.11 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 495.0 W
- PTC Wattage
- 470.9 W
- Voc @ 25C
- 43.57 V
- Efficiency
- 23.13%
How Does Thornova Solar TS-BBT60(495) Compare Against Peer CEC Listings?
How Thornova Solar Thornova Solar TS-BBT60(495) handles rooftop heat (470.9 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Thornova Solar TS-BBT60(495) exhibits 13.83 A short-circuit current, requiring a 21.57 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #4,591 of 21,677 (85.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 36.4 m2 for an 8 kW system (21 panels for 10 kW). Mid-range 43.57 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Thornova Solar TS-BBT60(495) Fall Across Listed CEC Models?
Where Thornova Solar TS-BBT60(495) (495.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-BBT60(495)?
Percentile placement of Thornova Solar TS-BBT60(495) across power density (231.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Thornova Solar TS-BBT60(495)?
Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-BBT60(495) specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Top 21.5% STC Output
495.0 W STC (+110.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.13% Aperture Efficiency
Power density 231.3 W/m2 (3.22 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 47.11 V at -10 C (565.3 V string) and 48.12 V at -20 C (12 max).
17 Panels = 8,415 W STC
Occupies 36.4 m2 (392 sq ft) producing 8,005 W PTC; NEC 690.8 OCPD floor is 21.57 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.57 * (1 + (-0.232/100) * (-10 - 25)) = 47.11 V | OCPD = 1.56 * 13.83 = 21.57 A
Inputs from CEC Modules.csv for Thornova Solar TS-BBT60(495): Voc=43.57 V, beta_Voc=-0.232%/C, Isc=13.83 A, STC=495.0 W, Area=2.14 m2.
Result: 12 panels max on 600 V (565.3 V); 17 panels for 8 kW (392 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BBT60(495)?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-BBT60(495).
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 495.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 470.9 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.57 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.31 V / 13.28 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.232 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.13% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BBT60(495) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-BBT60(495) (495.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.43 kW | 299 sq ft | $1,609 | $2,721 |
| 8 kW Class | 17 | 8.41 kW | 392 sq ft | $2,105 | $3,559 |
| 10 kW Class | 21 | 10.39 kW | 484 sq ft | $2,601 | $4,397 |
How Many Thornova Solar TS-BBT60(495) Modules Fit in a Cold-Weather String?
Maximum series module counts for Thornova Solar TS-BBT60(495) from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 48.12 V | 12 panels | 577.4 V | 20 panels |
| -10 C (14 F) | 47.11 V | 12 panels | 565.3 V | 21 panels |
| 0 C (32 F) | 46.1 V | 13 panels | 599.3 V | 21 panels |
| 25 C (77 F STC) | 43.57 V | 13 panels | 566.4 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BBT60(495)?
Alternative CEC solar modules from competing brands near Thornova Solar TS-BBT60(495) (495.0 W), including Elin Energy (Sirius PV) ELNSM66M-HC-BF-495.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 Elin Energy (Sirius PV) |
495.0 W | Tie (0 W) | 45.45 V | 21.02% | 94.4% |
| Aptos Solar Technology LLC DNA-132-BF10-490W Aptos Solar Technology LLC |
490.0 W | -5.0 W | 45.3 V | 20.68% | 94.2% |
| Boviet Solar Technology Co Ltd BVM7610M-485-H-HC-BF Boviet Solar Technology Co Ltd |
485.0 W | -10.0 W | 44.39 V | 22.45% | 95.0% |
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-475 Elin Energy (Sirius PV) |
475.0 W | -20.0 W | 41.82 V | 22.09% | 94.5% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BBT60(495)?
Evaluate Thornova Solar TS-BBT60(495) (495.0 W STC, 43.57 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BBT60(495) reaches 48.12 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 392 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (392 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BBT60(495) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BBT60(495) 8 kW Residential Fit
Needs 17 modules (392 sq ft) with a 25 A string OCPD, offsetting ~$2,105/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM66M-HC-BF-495.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 470.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BBT60(495) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Thornova Solar TS-BBT60(495) PTC wattage (470.9 W) lower than STC (495.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 470.9 W PTC (95.1% retention) across Thornova Solar TS-BBT60(495)'s 2.14 m2 aperture.
Who should skip Thornova Solar TS-BBT60(495) on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 Thornova Solar TS-BBT60(495) panels (392 sq ft) leave unusable roof gaps vs. Elin Energy (Sirius PV) ELNSM66M-HC-BF-495.
What is the 1,000 V commercial string limit for Thornova Solar TS-BBT60(495)?
On 1,000 V commercial inverters at -10 C (47.11 V cold Voc), Thornova Solar TS-BBT60(495) fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Thornova Solar TS-BBT60(495).
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)