Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 is a 495.0 W STC (467.3 W PTC) Mono-c-Si solar module ranking #4,591 of 21,677 CEC listings (top 21.5%; higher than 78.5% of peers). It delivers 21.02% efficiency, 45.45 V Voc at 25 C, and 49.3 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 495.0 W
- PTC Wattage
- 467.3 W
- Voc @ 25C
- 45.45 V
- Efficiency
- 21.02%
How Does Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 Compare Against Peer CEC Listings?
Solar engineering breakdown for Elin Energy (Sirius PV) ELNSM66M-HC-BF-495: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Elin Energy (Sirius PV) and peers, Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 stands 85.0 W above the 410.0 W Mono-c-Si median and strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Sizing 6 kW (13 panels) to 10 kW (21 panels) yields $1,609-$2,601/yr in baseline US bill offset. Mid-range 45.45 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 Fall Across Listed CEC Models?
Distribution marker showing Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 (495.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM66M-HC-BF-495?
Dataset percentiles tracking Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM66M-HC-BF-495?
Benchmark highlights for Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 21.5% STC Output
495.0 W STC (+110.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.02% Aperture Efficiency
Power density 210.2 W/m2 (1.11 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.3 V at -10 C (591.6 V string) and 50.4 V at -20 C (11 max).
17 Panels = 8,415 W STC
Occupies 40.0 m2 (431 sq ft) producing 7,944 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.45 * (1 + (-0.242/100) * (-10 - 25)) = 49.3 V | OCPD = 1.56 * 13.85 = 21.61 A
Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM66M-HC-BF-495: Voc=45.45 V, beta_Voc=-0.242%/C, Isc=13.85 A, STC=495.0 W, Area=2.355 m2.
Result: 12 panels max on 600 V (591.6 V); 17 panels for 8 kW (431 sq ft).
What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM66M-HC-BF-495?
Official CEC datasheet figures for Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 495.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 467.3 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.45 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.85 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.39 V / 13.24 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.242 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.02% (2.355 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.43 kW | 330 sq ft | $1,609 | $2,721 |
| 8 kW Class | 17 | 8.41 kW | 431 sq ft | $2,105 | $3,559 |
| 10 kW Class | 21 | 10.39 kW | 532 sq ft | $2,601 | $4,397 |
Which Sibling Wattage & Trim Variants Belong to This Elin Energy (Sirius PV) Series?
Consolidated Elin Energy (Sirius PV) wattage variants sharing the Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM66M-HC-BF-490 | 490.0 W | 462.5 W | 45.25 V | 37.23 V | 20.8% |
| Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 | 495.0 W | 467.3 W | 45.45 V | 37.39 V | 21.02% |
How Many Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 (49.3 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.4 V | 11 panels | 554.4 V | 19 panels |
| -10 C (14 F) | 49.3 V | 12 panels | 591.6 V | 20 panels |
| 0 C (32 F) | 48.2 V | 12 panels | 578.4 V | 20 panels |
| 25 C (77 F STC) | 45.45 V | 13 panels | 590.9 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM66M-HC-BF-495?
Competing CEC solar panels closest to Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-132-BF10-490W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-132-BF10-490W Aptos Solar Technology LLC |
490.0 W | -5.0 W | 45.3 V | 20.68% | 94.2% |
| Boviet Solar Technology Co Ltd BVM7610M-485-H-HC-BF Boviet Solar Technology Co Ltd |
485.0 W | -10.0 W | 44.39 V | 22.45% | 95.0% |
| CSI Solar Co Ltd CS3Y-485MB-AG CSI Solar Co Ltd |
485.0 W | -10.0 W | 53.1 V | 21.09% | 93.5% |
| Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF Boviet Solar Technology Co Ltd |
460.0 W | -35.0 W | 43.44 V | 21.3% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM66M-HC-BF-495?
Evaluate Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 (495.0 W STC, 45.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 reaches 50.4 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 431 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (431 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 8 kW Residential Fit
Needs 17 modules (431 sq ft) with a 25 A string OCPD, offsetting ~$2,105/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Aptos Solar Technology LLC DNA-132-BF10-490W.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 467.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Elin Energy (Sirius PV) ELNSM66M-HC-BF-495?
Multiplying Elin Energy (Sirius PV) ELNSM66M-HC-BF-495's 13.85 A short-circuit current by 1.56 equals 21.61 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 49.3 V cold Voc at 14 F and handles 13.85 A Isc; string inverters cap Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 at 12 panels on 600 V.
Is Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 rely on utility bill offset (~$2,105/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)