Skip to main content
WireAndSun
Calculators
CEC PV Module

Thornova Solar TS-BBT54(490)-G12R — CEC Solar Module Specifications

Manufacturer: Thornova Solar Registry: CEC Verified Engineering Specification

Thornova Solar TS-BBT54(490)-G12R is a 490.0 W STC (465.4 W PTC) Mono-c-Si solar module ranking #4,659 of 21,677 CEC listings (top 21.8%; higher than 78.2% of peers). It delivers 22.27% efficiency, 39.5 V Voc at 25 C, and 42.56 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
490.0 W
PTC Wattage
465.4 W
Voc @ 25C
39.5 V
Efficiency
22.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Thornova Solar TS-BBT54(490)-G12R Compare Against Peer CEC Listings?

Engineering position of Thornova Solar TS-BBT54(490)-G12R (490.0 W STC) vs. Aptos Solar Technology LLC DNA-132-BF10-490W across 5,889 CEC Mono-c-Si solar modules.

Built with 54 Mono-c-Si cells, Thornova Solar TS-BBT54(490)-G12R pairs strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677) with 39.5 V nominal Voc. An 8 kW residential build (8,330 W DC, 7,912 W PTC) saves ~$2,085/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Aptos Solar Technology LLC DNA-132-BF10-490W offers a 490.0 W alternative.

Where Does Thornova Solar TS-BBT54(490)-G12R Fall Across Listed CEC Models?

Plots Thornova Solar TS-BBT54(490)-G12R at 490.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Thornova Solar TS-BBT54(490)-G12R (490.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCThornova Solar TS-: 490.0 W

What Dataset Percentiles Define Thornova Solar TS-BBT54(490)-G12R?

Benchmarks Thornova Solar TS-BBT54(490)-G12R on STC wattage, thermal PTC/STC retention, and 22.27 aperture conversion efficiency against CEC peers.

Thornova Solar TS-BBT54(490)-G12R Engineering BenchmarksPercentile comparison of Thornova Solar TS-BBT54(490)-G12R wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage490.0 WPTC/STC Retention95.0%Module Efficiency22.27%

What Do the Dataset Ranks Show for Thornova Solar TS-BBT54(490)-G12R?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-BBT54(490)-G12R by Thornova Solar.

Rank #4,659 / 21,677

Top 21.8% STC Output

490.0 W STC (+105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,523

22.27% Aperture Efficiency

Power density 222.7 W/m2 (2.36 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.56 V at -10 C (595.8 V string) and 43.43 V at -20 C (13 max).

8 kW Reference Array

17 Panels = 8,330 W STC

Occupies 37.4 m2 (403 sq ft) producing 7,912 W PTC; NEC 690.8 OCPD floor is 24.65 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.5 * (1 + (-0.221/100) * (-10 - 25)) = 42.56 V | OCPD = 1.56 * 15.8 = 24.65 A

Inputs from CEC Modules.csv for Thornova Solar TS-BBT54(490)-G12R: Voc=39.5 V, beta_Voc=-0.221%/C, Isc=15.8 A, STC=490.0 W, Area=2.2 m2.

Result: 14 panels max on 600 V (595.8 V); 17 panels for 8 kW (403 sq ft).

What Are the Published CEC Specifications for Thornova Solar TS-BBT54(490)-G12R?

Laboratory test ratings recorded for Thornova Solar TS-BBT54(490)-G12R (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BBT54(490)-G12R.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 490.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 465.4 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 15.8 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.88 V / 14.91 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.221 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.27% (2.2 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many Thornova Solar TS-BBT54(490)-G12R Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (403 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-BBT54(490)-G12R.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.37 kW 308 sq ft $1,594 $2,696
8 kW Class 17 8.33 kW 403 sq ft $2,085 $3,525
10 kW Class 21 10.29 kW 497 sq ft $2,575 $4,355

How Many Thornova Solar TS-BBT54(490)-G12R Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Thornova Solar TS-BBT54(490)-G12R (beta_Voc -0.221%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=39.5V and beta_Voc=-0.221%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.43 V 13 panels 564.6 V 23 panels
-10 C (14 F) 42.56 V 14 panels 595.8 V 23 panels
0 C (32 F) 41.68 V 14 panels 583.5 V 23 panels
25 C (77 F STC) 39.5 V 15 panels 592.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BBT54(490)-G12R?

Closest cross-brand CEC competitors to Thornova Solar TS-BBT54(490)-G12R matched near 490.0 W STC and 39.5 V Voc, led by Aptos Solar Technology LLC DNA-132-BF10-490W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-132-BF10-490W
Aptos Solar Technology LLC
490.0 W Tie (0 W) 45.3 V 20.68% 94.2%
Elin Energy (Sirius PV) ELNSM60M-HC-BF-475
Elin Energy (Sirius PV)
475.0 W -15.0 W 41.82 V 22.09% 94.5%
Boviet Solar Technology Co Ltd BVM7610M-485-H-HC-BF
Boviet Solar Technology Co Ltd
485.0 W -5.0 W 44.39 V 22.45% 95.0%
Elin Energy (Sirius PV) ELNSM66M-HC-BF-495
Elin Energy (Sirius PV)
495.0 W +5.0 W 45.45 V 21.02% 94.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BBT54(490)-G12R?

Evaluate Thornova Solar TS-BBT54(490)-G12R (490.0 W STC, 39.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BBT54(490)-G12R reaches 43.43 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 403 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (403 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BBT54(490)-G12R carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Thornova Solar TS-BBT54(490)-G12R 8 kW Residential Fit

Needs 17 modules (403 sq ft) with a 25 A string OCPD, offsetting ~$2,085/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-132-BF10-490W.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 465.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BBT54(490)-G12R by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BBT54(490)-G12R?

Multiplying Thornova Solar TS-BBT54(490)-G12R's 15.8 A short-circuit current by 1.56 equals 24.65 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Thornova Solar TS-BBT54(490)-G12R pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.56 V cold Voc at 14 F and handles 15.8 A Isc; string inverters cap Thornova Solar TS-BBT54(490)-G12R at 14 panels on 600 V.

Is Thornova Solar TS-BBT54(490)-G12R eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BBT54(490)-G12R rely on utility bill offset (~$2,085/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.