Sunrise Solartech SR-P672290 is a 290.0 W STC (257.8 W PTC) Multi-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.93% efficiency, 43.52 V Voc at 25 C, and 48.99 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 257.8 W
- Voc @ 25C
- 43.52 V
- Efficiency
- 14.93%
How Does Sunrise Solartech SR-P672290 Compare Against Peer CEC Listings?
Engineering position of Sunrise Solartech SR-P672290 (290.0 W STC) vs. Centrosolar America DM72 290 across 1,407 CEC Multi-c-Si solar modules.
Built with 72 Multi-c-Si cells, Sunrise Solartech SR-P672290 pairs typical 88.9% PTC-to-STC thermal output (257.8 W real-world rating) with 43.52 V nominal Voc. An 8 kW residential build (8,120 W DC, 7,218 W PTC) saves ~$2,032/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America DM72 290 offers a 290.0 W alternative.
Where Does Sunrise Solartech SR-P672290 Fall Across Listed CEC Models?
Plots Sunrise Solartech SR-P672290 at 290.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Sunrise Solartech SR-P672290?
Benchmarks Sunrise Solartech SR-P672290 on STC wattage, thermal PTC/STC retention, and 14.93 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Sunrise Solartech SR-P672290?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Sunrise Solartech SR-P672290 by Sunrise Solartech.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.93% Aperture Efficiency
Power density 149.3 W/m2 (4.98 percentage points below 19.91% CEC median). PTC/STC ratio: 88.9% (rank #20,819).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 48.99 V at -10 C (587.9 V string) and 50.55 V at -20 C (11 max).
28 Panels = 8,120 W STC
Occupies 54.4 m2 (585 sq ft) producing 7,218 W PTC; NEC 690.8 OCPD floor is 13.87 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.52 * (1 + (-0.359/100) * (-10 - 25)) = 48.99 V | OCPD = 1.56 * 8.89 = 13.87 A
Inputs from CEC Modules.csv for Sunrise Solartech SR-P672290: Voc=43.52 V, beta_Voc=-0.359%/C, Isc=8.89 A, STC=290.0 W, Area=1.942 m2.
Result: 12 panels max on 600 V (587.9 V); 28 panels for 8 kW (585 sq ft).
What Are the Published CEC Specifications for Sunrise Solartech SR-P672290?
Laboratory test ratings recorded for Sunrise Solartech SR-P672290 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 257.8 W (88.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.52 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.89 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.1 V / 8.27 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.359 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.93% (1.942 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Sunrise Solartech SR-P672290 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (585 sq ft at 8 kW), and estimated Year-1 electric bill offset for Sunrise Solartech SR-P672290.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 439 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 585 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 732 sq ft | $2,540 | $4,296 |
How Many Sunrise Solartech SR-P672290 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Sunrise Solartech SR-P672290 (beta_Voc -0.359%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.55 V | 11 panels | 556.0 V | 19 panels |
| -10 C (14 F) | 48.99 V | 12 panels | 587.9 V | 20 panels |
| 0 C (32 F) | 47.43 V | 12 panels | 569.2 V | 21 panels |
| 25 C (77 F STC) | 43.52 V | 13 panels | 565.8 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Sunrise Solartech SR-P672290?
Closest cross-brand CEC competitors to Sunrise Solartech SR-P672290 matched near 290.0 W STC and 43.52 V Voc, led by Centrosolar America DM72 290.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DM72 290 Centrosolar America |
290.0 W | Tie (0 W) | 44.4 V | 14.92% | 90.6% |
| Gintung Energy GTEC-290G6M Gintung Energy |
290.0 W | Tie (0 W) | 44.61 V | 14.83% | 89.6% |
| Gintung Energy GTEC-290G6S Gintung Energy |
290.0 W | Tie (0 W) | 44.84 V | 14.83% | 89.7% |
| AXITEC AC-290M/156-72S AXITEC |
290.0 W | Tie (0 W) | 44.98 V | 14.95% | 90.6% |
What Are the Design Limits and Best-Fit Uses for Sunrise Solartech SR-P672290?
Evaluate Sunrise Solartech SR-P672290 (290.0 W STC, 43.52 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Sunrise Solartech SR-P672290 reaches 50.55 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
- 2026 tax credit baseline: cash residential installs of Sunrise Solartech SR-P672290 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Sunrise Solartech SR-P672290 8 kW Residential Fit
Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 290.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 257.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Sunrise Solartech SR-P672290 by Sunrise Solartech grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Sunrise Solartech SR-P672290?
Multiplying Sunrise Solartech SR-P672290's 8.89 A short-circuit current by 1.56 equals 13.87 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Sunrise Solartech SR-P672290 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 48.99 V cold Voc at 14 F and handles 8.89 A Isc; string inverters cap Sunrise Solartech SR-P672290 at 12 panels on 600 V.
Is Sunrise Solartech SR-P672290 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sunrise Solartech SR-P672290 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)