Sunrise Solartech SR-M672305 is a 305.0 W STC (267.1 W PTC) Mono-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 15.7% efficiency, 44.53 V Voc at 25 C, and 50.19 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 305.0 W
- PTC Wattage
- 267.1 W
- Voc @ 25C
- 44.53 V
- Efficiency
- 15.7%
How Does Sunrise Solartech SR-M672305 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Sunrise Solartech SR-M672305 (Mono-c-Si) residential solar systems.
Sunrise Solartech SR-M672305 delivers 157.1 W/m2 (4.21 percentage points below 19.91% CEC median) and typical 87.6% PTC-to-STC thermal output (267.1 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (564 sq ft). At -4 F (-20 C), string voltage climbs to 51.8 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Auxin Solar AXN6P612T305G (305.0 W).
Where Does Sunrise Solartech SR-M672305 Fall Across Listed CEC Models?
Comparison of Sunrise Solartech SR-M672305 (305.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Sunrise Solartech SR-M672305?
Relative ranking of Sunrise Solartech SR-M672305 across nameplate watts, 87.6% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for Sunrise Solartech SR-M672305?
Summary of Sunrise Solartech SR-M672305 output rank, 8 kW array size (27 panels), efficiency rating, and 600 V string limit.
305.0 W STC · Higher Than 23.9%
305.0 W STC (-80.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.7% Aperture Efficiency
Power density 157.1 W/m2 (4.21 percentage points below 19.91% CEC median). PTC/STC ratio: 87.6% (rank #21,526).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.19 V at -10 C (552.1 V string) and 51.8 V at -20 C (11 max).
27 Panels = 8,235 W STC
Occupies 52.4 m2 (564 sq ft) producing 7,212 W PTC; NEC 690.8 OCPD floor is 14.2 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.53 * (1 + (-0.363/100) * (-10 - 25)) = 50.19 V | OCPD = 1.56 * 9.1 = 14.2 A
Inputs from CEC Modules.csv for Sunrise Solartech SR-M672305: Voc=44.53 V, beta_Voc=-0.363%/C, Isc=9.1 A, STC=305.0 W, Area=1.942 m2.
Result: 11 panels max on 600 V (552.1 V); 27 panels for 8 kW (564 sq ft).
What Are the Published CEC Specifications for Sunrise Solartech SR-M672305?
Complete CEC test sheet for Sunrise Solartech SR-M672305 including Isc (9.1 A), Voc (44.53 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 305.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 267.1 W (87.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.53 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.2 V / 8.43 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.363 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.7% (1.942 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Sunrise Solartech SR-M672305 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Sunrise Solartech SR-M672305.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.1 kW | 418 sq ft | $1,527 | $2,582 |
| 8 kW Class | 27 | 8.23 kW | 564 sq ft | $2,060 | $3,483 |
| 10 kW Class | 33 | 10.06 kW | 690 sq ft | $2,518 | $4,258 |
How Many Sunrise Solartech SR-M672305 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Sunrise Solartech SR-M672305 (44.53 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.8 V | 11 panels | 569.8 V | 19 panels |
| -10 C (14 F) | 50.19 V | 11 panels | 552.1 V | 19 panels |
| 0 C (32 F) | 48.57 V | 12 panels | 582.8 V | 20 panels |
| 25 C (77 F STC) | 44.53 V | 13 panels | 578.9 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Sunrise Solartech SR-M672305?
Four comparable CEC modules such as Auxin Solar AXN6P612T305G (305.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6P612T305G Auxin Solar |
305.0 W | Tie (0 W) | 45.0 V | 15.63% | 90.3% |
| Anhui Rinengzhongtian Semiconductor Development QJM310-72 Anhui Rinengzhongtian Semiconductor Development |
310.0 W | +5.0 W | 44.65 V | 15.98% | 90.0% |
| Anhui Rinengzhongtian Semiconductor Development QJP310-72 Anhui Rinengzhongtian Semiconductor Development |
310.0 W | +5.0 W | 44.65 V | 15.98% | 90.6% |
| CSI Solar Co Ltd CS6X-310P CSI Solar Co Ltd |
310.0 W | +5.0 W | 44.9 V | 16.31% | 91.4% |
What Are the Design Limits and Best-Fit Uses for Sunrise Solartech SR-M672305?
Evaluate Sunrise Solartech SR-M672305 (305.0 W STC, 44.53 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Sunrise Solartech SR-M672305 reaches 51.8 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 564 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (564 sq ft).
- 2026 tax credit baseline: cash residential installs of Sunrise Solartech SR-M672305 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Sunrise Solartech SR-M672305 8 kW Residential Fit
Needs 27 modules (564 sq ft) with a 15 A string OCPD, offsetting ~$2,060/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 267.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Sunrise Solartech SR-M672305 by Sunrise Solartech grounded in CEC test data and NEC 690.7/690.8 limits.
How many Sunrise Solartech SR-M672305 panels fit on a 600 V winter solar string?
At -10 C (14 F), Sunrise Solartech SR-M672305 cold Voc rises from 44.53 V to 50.19 V (beta_Voc -0.363%/C), capping a 600 V string at 11 panels (552.1 V).
How much roof area does an 8 kW array of Sunrise Solartech SR-M672305 need?
An 8 kW DC system uses 27 Sunrise Solartech SR-M672305 modules (8,235 W STC / 7,212 W PTC), covering roughly 564 sq ft and saving ~$2,060/yr at 18.54 c/kWh.
How does Sunrise Solartech SR-M672305 compare against Auxin Solar AXN6P612T305G?
Sunrise Solartech SR-M672305 outputs 305.0 W STC (44.53 V Voc, rank #16,131 of 21,677), while Auxin Solar AXN6P612T305G delivers 305.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)