Skip to main content
WireAndSun
Calculators
CEC PV Module

Sunrise Solartech SR-P672280 — CEC Solar Module Specifications

Manufacturer: Sunrise Solartech Registry: CEC Verified Engineering Specification

Sunrise Solartech SR-P672280 is a 280.0 W STC (248.7 W PTC) Multi-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 14.42% efficiency, 43.08 V Voc at 25 C, and 48.49 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
280.0 W
PTC Wattage
248.7 W
Voc @ 25C
43.08 V
Efficiency
14.42%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sunrise Solartech SR-P672280 Compare Against Peer CEC Listings?

Solar engineering breakdown for Sunrise Solartech SR-P672280: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Measured at 280.0 W STC and 248.7 W PTC, Sunrise Solartech SR-P672280 sits -105.0 W vs all-CEC median (below all-CEC median; higher than 15.8% of peers) among 21,677 listed modules. Power density reaches 144.2 W/m2 (5.49 percentage points below 19.91% CEC median). Mid-range 43.08 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer Anhui Rinengzhongtian Semiconductor Development QJP285-72 rates 285.0 W.

Where Does Sunrise Solartech SR-P672280 Fall Across Listed CEC Models?

Distribution marker showing Sunrise Solartech SR-P672280 (280.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Sunrise Solartech SR-P672280 (280.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunrise Solartech : 280.0 W

What Dataset Percentiles Define Sunrise Solartech SR-P672280?

Dataset percentiles tracking Sunrise Solartech SR-P672280 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sunrise Solartech SR-P672280 Engineering BenchmarksPercentile comparison of Sunrise Solartech SR-P672280 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage280.0 WPTC/STC Retention88.8%Module Efficiency14.42%

What Do the Dataset Ranks Show for Sunrise Solartech SR-P672280?

Benchmark highlights for Sunrise Solartech SR-P672280 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #17,941 / 21,677

280.0 W STC · Higher Than 15.8%

280.0 W STC (-105.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,520

14.42% Aperture Efficiency

Power density 144.2 W/m2 (5.49 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.49 V at -10 C (581.9 V string) and 50.04 V at -20 C (11 max).

8 kW Reference Array

29 Panels = 8,120 W STC

Occupies 56.3 m2 (606 sq ft) producing 7,212 W PTC; NEC 690.8 OCPD floor is 13.54 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.08 * (1 + (-0.359/100) * (-10 - 25)) = 48.49 V | OCPD = 1.56 * 8.68 = 13.54 A

Inputs from CEC Modules.csv for Sunrise Solartech SR-P672280: Voc=43.08 V, beta_Voc=-0.359%/C, Isc=8.68 A, STC=280.0 W, Area=1.942 m2.

Result: 12 panels max on 600 V (581.9 V); 29 panels for 8 kW (606 sq ft).

What Are the Published CEC Specifications for Sunrise Solartech SR-P672280?

Official CEC datasheet figures for Sunrise Solartech SR-P672280 (Multi-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for Sunrise Solartech SR-P672280.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 280.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 248.7 W (88.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.08 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.68 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.8 V / 8.05 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.359 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.42% (1.942 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Sunrise Solartech SR-P672280 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Sunrise Solartech SR-P672280 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.16 kW 460 sq ft $1,542 $2,607
8 kW Class 29 8.12 kW 606 sq ft $2,032 $3,437
10 kW Class 36 10.08 kW 753 sq ft $2,523 $4,266

How Many Sunrise Solartech SR-P672280 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Sunrise Solartech SR-P672280 (48.49 V at 14 F).

Computed from Voc=43.08V and beta_Voc=-0.359%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.04 V 11 panels 550.4 V 19 panels
-10 C (14 F) 48.49 V 12 panels 581.9 V 20 panels
0 C (32 F) 46.95 V 12 panels 563.4 V 21 panels
25 C (77 F STC) 43.08 V 13 panels 560.0 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Sunrise Solartech SR-P672280?

Competing CEC solar panels closest to Sunrise Solartech SR-P672280 in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development QJP285-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJP285-72
Anhui Rinengzhongtian Semiconductor Development
285.0 W +5.0 W 43.1 V 14.69% 89.3%
Anhui Rinengzhongtian Semiconductor Development QJM285-72
Anhui Rinengzhongtian Semiconductor Development
285.0 W +5.0 W 44.03 V 14.69% 89.8%
Advance Power API-M285
Advance Power
285.0 W +5.0 W 44.21 V 14.61% 89.1%
Advance Power API-P285
Advance Power
285.0 W +5.0 W 44.21 V 14.61% 90.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Sunrise Solartech SR-P672280?

Evaluate Sunrise Solartech SR-P672280 (280.0 W STC, 43.08 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Sunrise Solartech SR-P672280 reaches 50.04 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 606 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (606 sq ft).
  • 2026 tax credit baseline: cash residential installs of Sunrise Solartech SR-P672280 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Sunrise Solartech SR-P672280 8 kW Residential Fit

Needs 29 modules (606 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP285-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 248.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sunrise Solartech SR-P672280 by Sunrise Solartech grounded in CEC test data and NEC 690.7/690.8 limits.

How many Sunrise Solartech SR-P672280 panels fit on a 600 V winter solar string?

At -10 C (14 F), Sunrise Solartech SR-P672280 cold Voc rises from 43.08 V to 48.49 V (beta_Voc -0.359%/C), capping a 600 V string at 12 panels (581.9 V).

How much roof area does an 8 kW array of Sunrise Solartech SR-P672280 need?

An 8 kW DC system uses 29 Sunrise Solartech SR-P672280 modules (8,120 W STC / 7,212 W PTC), covering roughly 606 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

How does Sunrise Solartech SR-P672280 compare against Anhui Rinengzhongtian Semiconductor Development QJP285-72?

Sunrise Solartech SR-P672280 outputs 280.0 W STC (43.08 V Voc, rank #17,941 of 21,677), while Anhui Rinengzhongtian Semiconductor Development QJP285-72 delivers 285.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.