Skip to main content
WireAndSun
Calculators
CEC PV Module

Sunrise Solartech SR-P660225 — CEC Solar Module Specifications

Manufacturer: Sunrise Solartech Registry: CEC Verified Engineering Specification

Sunrise Solartech SR-P660225 is a 225.0 W STC (199.6 W PTC) Multi-c-Si solar module ranking #20,659 of 21,677 CEC listings (below all-CEC median; higher than 4.3% of peers). It delivers 13.86% efficiency, 35.46 V Voc at 25 C, and 39.92 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
225.0 W
PTC Wattage
199.6 W
Voc @ 25C
35.46 V
Efficiency
13.86%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sunrise Solartech SR-P660225 Compare Against Peer CEC Listings?

Solar engineering breakdown for Sunrise Solartech SR-P660225: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Across 1,407 Multi-c-Si listings from Sunrise Solartech and peers, Sunrise Solartech SR-P660225 stands 53.8 W below the 278.8 W Multi-c-Si median and typical 88.7% PTC-to-STC thermal output (199.6 W real-world rating). Sizing 6 kW (27 panels) to 10 kW (45 panels) yields $1,522-$2,533/yr in baseline US bill offset. Lower 35.46 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.

Where Does Sunrise Solartech SR-P660225 Fall Across Listed CEC Models?

Distribution marker showing Sunrise Solartech SR-P660225 (225.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Sunrise Solartech SR-P660225 (225.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunrise Solartech : 225.0 W

What Dataset Percentiles Define Sunrise Solartech SR-P660225?

Dataset percentiles tracking Sunrise Solartech SR-P660225 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sunrise Solartech SR-P660225 Engineering BenchmarksPercentile comparison of Sunrise Solartech SR-P660225 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage225.0 WPTC/STC Retention88.7%Module Efficiency13.86%

What Do the Dataset Ranks Show for Sunrise Solartech SR-P660225?

Benchmark highlights for Sunrise Solartech SR-P660225 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #20,659 / 21,677

225.0 W STC · Higher Than 4.3%

225.0 W STC (-160.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,999

13.86% Aperture Efficiency

Power density 138.5 W/m2 (6.05 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 39.92 V at -10 C (598.8 V string) and 41.19 V at -20 C (14 max).

8 kW Reference Array

36 Panels = 8,100 W STC

Occupies 58.5 m2 (629 sq ft) producing 7,186 W PTC; NEC 690.8 OCPD floor is 13.2 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.46 * (1 + (-0.359/100) * (-10 - 25)) = 39.92 V | OCPD = 1.56 * 8.46 = 13.2 A

Inputs from CEC Modules.csv for Sunrise Solartech SR-P660225: Voc=35.46 V, beta_Voc=-0.359%/C, Isc=8.46 A, STC=225.0 W, Area=1.624 m2.

Result: 15 panels max on 600 V (598.8 V); 36 panels for 8 kW (629 sq ft).

What Are the Published CEC Specifications for Sunrise Solartech SR-P660225?

Official CEC datasheet figures for Sunrise Solartech SR-P660225 (Multi-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for Sunrise Solartech SR-P660225.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 225.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 199.6 W (88.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 35.46 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.46 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 28.6 V / 7.87 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.359 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.86% (1.624 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Sunrise Solartech SR-P660225 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Sunrise Solartech SR-P660225 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 27 6.08 kW 472 sq ft $1,522 $2,573
8 kW Class 36 8.1 kW 629 sq ft $2,027 $3,428
10 kW Class 45 10.12 kW 787 sq ft $2,533 $4,283

How Many Sunrise Solartech SR-P660225 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Sunrise Solartech SR-P660225 (39.92 V at 14 F).

Computed from Voc=35.46V and beta_Voc=-0.359%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.19 V 14 panels 576.7 V 24 panels
-10 C (14 F) 39.92 V 15 panels 598.8 V 25 panels
0 C (32 F) 38.64 V 15 panels 579.6 V 25 panels
25 C (77 F STC) 35.46 V 16 panels 567.4 V 28 panels

Which Cross-Brand Solar Modules Compare Closest to Sunrise Solartech SR-P660225?

Competing CEC solar panels closest to Sunrise Solartech SR-P660225 in nameplate wattage and Voc, starting with Hanwha Qcells (Qidong) Co Ltd SF220-30-M225.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanwha Qcells (Qidong) Co Ltd SF220-30-M225
Hanwha Qcells (Qidong) Co Ltd
225.0 W Tie (0 W) 36.8 V 13.62% 90.2%
Alps Technology ATI-M660-220
Alps Technology
220.0 W -5.0 W 36.06 V 13.67% 86.0%
Anji Technology AJP-M660-220
Anji Technology
220.0 W -5.0 W 36.06 V 13.55% 86.0%
Centrosolar America DP60 220
Centrosolar America
220.0 W -5.0 W 36.26 V 13.42% 89.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Sunrise Solartech SR-P660225?

Evaluate Sunrise Solartech SR-P660225 (225.0 W STC, 35.46 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Sunrise Solartech SR-P660225 reaches 41.19 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 36 panels for an 8 kW build require 629 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 36 panels (629 sq ft).
  • 2026 tax credit baseline: cash residential installs of Sunrise Solartech SR-P660225 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Sunrise Solartech SR-P660225 8 kW Residential Fit

Needs 36 modules (629 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd SF220-30-M225.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 199.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sunrise Solartech SR-P660225 by Sunrise Solartech grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Sunrise Solartech SR-P660225?

Multiplying Sunrise Solartech SR-P660225's 8.46 A short-circuit current by 1.56 equals 13.2 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Sunrise Solartech SR-P660225 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 39.92 V cold Voc at 14 F and handles 8.46 A Isc; string inverters cap Sunrise Solartech SR-P660225 at 15 panels on 600 V.

Is Sunrise Solartech SR-P660225 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sunrise Solartech SR-P660225 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.