Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 is a 225.0 W STC (202.9 W PTC) Mono-c-Si solar module ranking #20,659 of 21,677 CEC listings (below all-CEC median; higher than 4.3% of peers). It delivers 13.62% efficiency, 36.8 V Voc at 25 C, and 41.17 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 225.0 W
- PTC Wattage
- 202.9 W
- Voc @ 25C
- 36.8 V
- Efficiency
- 13.62%
How Does Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 Compare Against Peer CEC Listings?
Engineering position of Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 (225.0 W STC) vs. Grape Solar GS-P-230-CS across 5,889 CEC Mono-c-Si solar modules.
Built with 60 Mono-c-Si cells, Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 pairs typical 90.2% PTC-to-STC thermal output (202.9 W real-world rating) with 36.8 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,304 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Grape Solar GS-P-230-CS offers a 230.0 W alternative.
Where Does Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 Fall Across Listed CEC Models?
Plots Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 at 225.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd SF220-30-M225?
Benchmarks Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 on STC wattage, thermal PTC/STC retention, and 13.62 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd SF220-30-M225?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 by Hanwha Qcells (Qidong) Co Ltd.
225.0 W STC · Higher Than 4.3%
225.0 W STC (-160.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
13.62% Aperture Efficiency
Power density 136.2 W/m2 (6.29 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.17 V at -10 C (576.4 V string) and 42.41 V at -20 C (14 max).
36 Panels = 8,100 W STC
Occupies 59.5 m2 (640 sq ft) producing 7,304 W PTC; NEC 690.8 OCPD floor is 12.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.8 * (1 + (-0.339/100) * (-10 - 25)) = 41.17 V | OCPD = 1.56 * 8.16 = 12.73 A
Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd SF220-30-M225: Voc=36.8 V, beta_Voc=-0.339%/C, Isc=8.16 A, STC=225.0 W, Area=1.652 m2.
Result: 14 panels max on 600 V (576.4 V); 36 panels for 8 kW (640 sq ft).
What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd SF220-30-M225?
Laboratory test ratings recorded for Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 225.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 202.9 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.16 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.1 V / 7.48 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.339 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.62% (1.652 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (640 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hanwha Qcells (Qidong) Co Ltd SF220-30-M225.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 27 | 6.08 kW | 480 sq ft | $1,522 | $2,573 |
| 8 kW Class | 36 | 8.1 kW | 640 sq ft | $2,027 | $3,428 |
| 10 kW Class | 45 | 10.12 kW | 800 sq ft | $2,533 | $4,283 |
How Many Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 (beta_Voc -0.339%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.41 V | 14 panels | 593.7 V | 23 panels |
| -10 C (14 F) | 41.17 V | 14 panels | 576.4 V | 24 panels |
| 0 C (32 F) | 39.92 V | 15 panels | 598.8 V | 25 panels |
| 25 C (77 F STC) | 36.8 V | 16 panels | 588.8 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd SF220-30-M225?
Closest cross-brand CEC competitors to Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 matched near 225.0 W STC and 36.8 V Voc, led by Grape Solar GS-P-230-CS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Grape Solar GS-P-230-CS Grape Solar |
230.0 W | +5.0 W | 36.8 V | 14.3% | 91.7% |
| Gintung Energy ASEC-230G6S Gintung Energy |
230.0 W | +5.0 W | 36.75 V | 14.28% | 89.7% |
| Gintung Energy ASEC-230G6M Gintung Energy |
230.0 W | +5.0 W | 36.87 V | 14.28% | 89.4% |
| Anji Dasol Solar Energy Science & Technology DS-A4-230 Anji Dasol Solar Energy Science & Technology |
230.0 W | +5.0 W | 36.9 V | 13.97% | 87.3% |
What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd SF220-30-M225?
Evaluate Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 (225.0 W STC, 36.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 reaches 42.41 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 36 panels for an 8 kW build require 640 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 36 panels (640 sq ft).
- 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 8 kW Residential Fit
Needs 36 modules (640 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Grape Solar GS-P-230-CS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 202.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hanwha Qcells (Qidong) Co Ltd SF220-30-M225?
Multiplying Hanwha Qcells (Qidong) Co Ltd SF220-30-M225's 8.16 A short-circuit current by 1.56 equals 12.73 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.17 V cold Voc at 14 F and handles 8.16 A Isc; string inverters cap Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 at 14 panels on 600 V.
Is Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)