Skip to main content
WireAndSun
Calculators
CEC PV Module

Gintung Energy ASEC-230G6S — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy ASEC-230G6S is a 230.0 W STC (206.2 W PTC) Mono-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 14.28% efficiency, 36.75 V Voc at 25 C, and 41.12 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
230.0 W
PTC Wattage
206.2 W
Voc @ 25C
36.75 V
Efficiency
14.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy ASEC-230G6S Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Gintung Energy ASEC-230G6S (Mono-c-Si) residential solar systems.

Gintung Energy ASEC-230G6S delivers 142.8 W/m2 (5.63 percentage points below 19.91% CEC median) and typical 89.7% PTC-to-STC thermal output (206.2 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (607 sq ft). At -4 F (-20 C), string voltage climbs to 42.37 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with Grape Solar GS-P-230-CS (230.0 W).

Where Does Gintung Energy ASEC-230G6S Fall Across Listed CEC Models?

Comparison of Gintung Energy ASEC-230G6S (230.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy ASEC-230G6S (230.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy ASE: 230.0 W

What Dataset Percentiles Define Gintung Energy ASEC-230G6S?

Relative ranking of Gintung Energy ASEC-230G6S across nameplate watts, 89.7% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Gintung Energy ASEC-230G6S Engineering BenchmarksPercentile comparison of Gintung Energy ASEC-230G6S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage230.0 WPTC/STC Retention89.7%Module Efficiency14.28%

What Do the Dataset Ranks Show for Gintung Energy ASEC-230G6S?

Summary of Gintung Energy ASEC-230G6S output rank, 8 kW array size (35 panels), efficiency rating, and 600 V string limit.

Rank #20,522 / 21,677

230.0 W STC · Higher Than 4.7%

230.0 W STC (-155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,643

14.28% Aperture Efficiency

Power density 142.8 W/m2 (5.63 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.12 V at -10 C (575.7 V string) and 42.37 V at -20 C (14 max).

8 kW Reference Array

35 Panels = 8,050 W STC

Occupies 56.4 m2 (607 sq ft) producing 7,217 W PTC; NEC 690.8 OCPD floor is 13.2 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.75 * (1 + (-0.34/100) * (-10 - 25)) = 41.12 V | OCPD = 1.56 * 8.46 = 13.2 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-230G6S: Voc=36.75 V, beta_Voc=-0.34%/C, Isc=8.46 A, STC=230.0 W, Area=1.611 m2.

Result: 14 panels max on 600 V (575.7 V); 35 panels for 8 kW (607 sq ft).

What Are the Published CEC Specifications for Gintung Energy ASEC-230G6S?

Complete CEC test sheet for Gintung Energy ASEC-230G6S including Isc (8.46 A), Voc (36.75 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-230G6S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 230.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 206.2 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.75 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.46 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.19 V / 7.88 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.28% (1.611 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Gintung Energy ASEC-230G6S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Gintung Energy ASEC-230G6S.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 27 6.21 kW 468 sq ft $1,554 $2,628
8 kW Class 35 8.05 kW 607 sq ft $2,015 $3,407
10 kW Class 44 10.12 kW 763 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Related Gintung Energy power steps and black/silver trims consolidated into this Gintung Energy ASEC-230G6S series guide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Gintung Energy ASEC-230G6S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Gintung Energy ASEC-225G6S 225.0 W 201.6 W 36.65 V 29.08 V 13.97%
Gintung Energy ASEC-230G6S 230.0 W 206.2 W 36.75 V 29.19 V 14.28%
Gintung Energy ASEC-235G6S 235.0 W 210.8 W 36.88 V 29.27 V 14.59%

How Many Gintung Energy ASEC-230G6S Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Gintung Energy ASEC-230G6S (36.75 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=36.75V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.37 V 14 panels 593.2 V 23 panels
-10 C (14 F) 41.12 V 14 panels 575.7 V 24 panels
0 C (32 F) 39.87 V 15 panels 598.0 V 25 panels
25 C (77 F STC) 36.75 V 16 panels 588.0 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-230G6S?

Four comparable CEC modules such as Grape Solar GS-P-230-CS (230.0 W) for side-by-side solar quote checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Grape Solar GS-P-230-CS
Grape Solar
230.0 W Tie (0 W) 36.8 V 14.3% 91.7%
Anji Dasol Solar Energy Science & Technology DS-A4-230
Anji Dasol Solar Energy Science & Technology
230.0 W Tie (0 W) 36.9 V 13.97% 87.3%
Guangdong Golden Glass Technologies GG230M2-30/1640x992
Guangdong Golden Glass Technologies
230.0 W Tie (0 W) 37.0 V 14.14% 90.3%
APOS Energy AP230
APOS Energy
230.0 W Tie (0 W) 37.32 V 13.86% 89.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-230G6S?

Evaluate Gintung Energy ASEC-230G6S (230.0 W STC, 36.75 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-230G6S reaches 42.37 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 607 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (607 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-230G6S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy ASEC-230G6S 8 kW Residential Fit

Needs 35 modules (607 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Grape Solar GS-P-230-CS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 206.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-230G6S by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Gintung Energy ASEC-230G6S panels fit on a 600 V winter solar string?

At -10 C (14 F), Gintung Energy ASEC-230G6S cold Voc rises from 36.75 V to 41.12 V (beta_Voc -0.34%/C), capping a 600 V string at 14 panels (575.7 V).

How much roof area does an 8 kW array of Gintung Energy ASEC-230G6S need?

An 8 kW DC system uses 35 Gintung Energy ASEC-230G6S modules (8,050 W STC / 7,217 W PTC), covering roughly 607 sq ft and saving ~$2,015/yr at 18.54 c/kWh.

How does Gintung Energy ASEC-230G6S compare against Grape Solar GS-P-230-CS?

Gintung Energy ASEC-230G6S outputs 230.0 W STC (36.75 V Voc, rank #20,522 of 21,677), while Grape Solar GS-P-230-CS delivers 230.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.