Skip to main content
WireAndSun
Calculators
CEC PV Module

Solarmax SEAP72-290 — CEC Solar Module Specifications

Manufacturer: Solarmax Registry: CEC Verified Engineering Specification

Solarmax SEAP72-290 is a 290.0 W STC (258.8 W PTC) Multi-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.95% efficiency, 45.32 V Voc at 25 C, and 50.52 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
290.0 W
PTC Wattage
258.8 W
Voc @ 25C
45.32 V
Efficiency
14.95%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solarmax SEAP72-290 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Solarmax SEAP72-290 (Multi-c-Si) residential solar systems. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Solarmax SEAP72-290 delivers 149.5 W/m2 (4.96 percentage points below 19.91% CEC median) and typical 89.2% PTC-to-STC thermal output (258.8 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft). At -4 F (-20 C), string voltage climbs to 52.01 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with AXITEC AC-290M/156-72S (290.0 W).

Where Does Solarmax SEAP72-290 Fall Across Listed CEC Models?

Comparison of Solarmax SEAP72-290 (290.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solarmax SEAP72-290 (290.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolarmax SEAP72-29: 290.0 W

What Dataset Percentiles Define Solarmax SEAP72-290?

Relative ranking of Solarmax SEAP72-290 across nameplate watts, 89.2% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Solarmax SEAP72-290 Engineering BenchmarksPercentile comparison of Solarmax SEAP72-290 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage290.0 WPTC/STC Retention89.2%Module Efficiency14.95%

What Do the Dataset Ranks Show for Solarmax SEAP72-290?

Summary of Solarmax SEAP72-290 output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #17,253 / 21,677

290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,805

14.95% Aperture Efficiency

Power density 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.52 V at -10 C (555.7 V string) and 52.01 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,120 W STC

Occupies 54.3 m2 (585 sq ft) producing 7,246 W PTC; NEC 690.8 OCPD floor is 13.31 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.32 * (1 + (-0.328/100) * (-10 - 25)) = 50.52 V | OCPD = 1.56 * 8.53 = 13.31 A

Inputs from CEC Modules.csv for Solarmax SEAP72-290: Voc=45.32 V, beta_Voc=-0.328%/C, Isc=8.53 A, STC=290.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (555.7 V); 28 panels for 8 kW (585 sq ft).

What Are the Published CEC Specifications for Solarmax SEAP72-290?

Complete CEC test sheet for Solarmax SEAP72-290 including Isc (8.53 A), Voc (45.32 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Solarmax SEAP72-290.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 290.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 258.8 W (89.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.32 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.53 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.73 V / 8.12 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.328 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.95% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Solarmax SEAP72-290 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Solarmax SEAP72-290.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.09 kW 439 sq ft $1,524 $2,577
8 kW Class 28 8.12 kW 585 sq ft $2,032 $3,437
10 kW Class 35 10.15 kW 731 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This Solarmax Series?

Related Solarmax power steps and black/silver trims consolidated into this Solarmax SEAP72-290 series guide. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the Solarmax SEAP72-290 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solarmax SEAP72-280 280.0 W 249.6 W 44.53 V 35.11 V 14.43%
Solarmax SEAP72-285 285.0 W 254.2 W 44.93 V 35.42 V 14.69%
Solarmax SEAP72-290 290.0 W 258.8 W 45.32 V 35.73 V 14.95%
Solarmax SEAP72-295 295.0 W 263.4 W 45.71 V 36.04 V 15.2%

How Many Solarmax SEAP72-290 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Solarmax SEAP72-290 (45.32 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.32V and beta_Voc=-0.328%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.01 V 11 panels 572.1 V 19 panels
-10 C (14 F) 50.52 V 11 panels 555.7 V 19 panels
0 C (32 F) 49.04 V 12 panels 588.5 V 20 panels
25 C (77 F STC) 45.32 V 13 panels 589.2 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Solarmax SEAP72-290?

Four comparable CEC modules such as AXITEC AC-290M/156-72S (290.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-290M/156-72S
AXITEC
290.0 W Tie (0 W) 44.98 V 14.95% 90.6%
Gintung Energy GTEC-290G6S
Gintung Energy
290.0 W Tie (0 W) 44.84 V 14.83% 89.7%
Gintung Energy GTEC-290G6M
Gintung Energy
290.0 W Tie (0 W) 44.61 V 14.83% 89.6%
Centrosolar America DM72 290
Centrosolar America
290.0 W Tie (0 W) 44.4 V 14.92% 90.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solarmax SEAP72-290?

Evaluate Solarmax SEAP72-290 (290.0 W STC, 45.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solarmax SEAP72-290 reaches 52.01 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solarmax SEAP72-290 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solarmax SEAP72-290 8 kW Residential Fit

Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-290M/156-72S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 258.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solarmax SEAP72-290 by Solarmax grounded in CEC test data and NEC 690.7/690.8 limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

How many Solarmax SEAP72-290 panels fit on a 600 V winter solar string?

At -10 C (14 F), Solarmax SEAP72-290 cold Voc rises from 45.32 V to 50.52 V (beta_Voc -0.328%/C), capping a 600 V string at 11 panels (555.7 V).

How much roof area does an 8 kW array of Solarmax SEAP72-290 need?

An 8 kW DC system uses 28 Solarmax SEAP72-290 modules (8,120 W STC / 7,246 W PTC), covering roughly 585 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

How does Solarmax SEAP72-290 compare against AXITEC AC-290M/156-72S?

Solarmax SEAP72-290 outputs 290.0 W STC (45.32 V Voc, rank #17,253 of 21,677), while AXITEC AC-290M/156-72S delivers 290.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.