Solarmax SEAP60-240 — CEC Solar Module Specifications

Manufacturer: Solarmax Registry: CEC Verified Engineering Specification

Solarmax SEAP60-240 is a 240.0 W STC (214.1 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.73% efficiency, 37.64 V Voc at 25 C, and 41.96 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
240.0 W
PTC Wattage
214.1 W
Voc @ 25C
37.64 V
Efficiency
14.73%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solarmax SEAP60-240 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Solarmax SEAP60-240 (Mono-c-Si) residential solar systems. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Solarmax SEAP60-240 delivers 147.3 W/m2 (5.18 percentage points below 19.91% CEC median) and typical 89.2% PTC-to-STC thermal output (214.1 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (596 sq ft). At -4 F (-20 C), string voltage climbs to 43.2 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Centrosolar America EP6 240 BW (240.0 W).

Where Does Solarmax SEAP60-240 Fall Across Listed CEC Models?

Comparison of Solarmax SEAP60-240 (240.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solarmax SEAP60-240 (240.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolarmax SEAP60-24: 240.0 W

What Dataset Percentiles Define Solarmax SEAP60-240?

Relative ranking of Solarmax SEAP60-240 across nameplate watts, 89.2% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Solarmax SEAP60-240 Engineering BenchmarksPercentile comparison of Solarmax SEAP60-240 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage240.0 WPTC/STC Retention89.2%Module Efficiency14.73%

What Do the Dataset Ranks Show for Solarmax SEAP60-240?

Summary of Solarmax SEAP60-240 output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.

Rank #20,160 / 21,677

240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,135

14.73% Aperture Efficiency

Power density 147.3 W/m2 (5.18 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.96 V at -10 C (587.4 V string) and 43.2 V at -20 C (13 max).

8 kW Reference Array

34 Panels = 8,160 W STC

Occupies 55.4 m2 (596 sq ft) producing 7,279 W PTC; NEC 690.8 OCPD floor is 13.26 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.64 * (1 + (-0.328/100) * (-10 - 25)) = 41.96 V | OCPD = 1.56 * 8.5 = 13.26 A

Inputs from CEC Modules.csv for Solarmax SEAP60-240: Voc=37.64 V, beta_Voc=-0.328%/C, Isc=8.5 A, STC=240.0 W, Area=1.629 m2.

Result: 14 panels max on 600 V (587.4 V); 34 panels for 8 kW (596 sq ft).

What Are the Published CEC Specifications for Solarmax SEAP60-240?

Complete CEC test sheet for Solarmax SEAP60-240 including Isc (8.5 A), Voc (37.64 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Solarmax SEAP60-240.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 240.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 214.1 W (89.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.64 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.67 V / 8.09 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.328 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.73% (1.629 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Solarmax SEAP60-240 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Solarmax SEAP60-240.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.0 kW 438 sq ft $1,502 $2,539
8 kW Class 34 8.16 kW 596 sq ft $2,042 $3,454
10 kW Class 42 10.08 kW 736 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Solarmax Series?

Related Solarmax power steps and black/silver trims consolidated into this Solarmax SEAP60-240 series guide. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the Solarmax SEAP60-240 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solarmax SEAP60-230 230.0 W 204.9 W 36.85 V 29.05 V 14.12%
Solarmax SEAP60-235 235.0 W 209.5 W 37.24 V 29.36 V 14.43%
Solarmax SEAP60-240 240.0 W 214.1 W 37.64 V 29.67 V 14.73%
Solarmax SEAP60-245 245.0 W 218.7 W 38.03 V 29.98 V 15.04%

How Many Solarmax SEAP60-240 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Solarmax SEAP60-240 (37.64 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.64V and beta_Voc=-0.328%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.2 V 13 panels 561.6 V 23 panels
-10 C (14 F) 41.96 V 14 panels 587.4 V 23 panels
0 C (32 F) 40.73 V 14 panels 570.2 V 24 panels
25 C (77 F STC) 37.64 V 15 panels 564.6 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Solarmax SEAP60-240?

Four comparable CEC modules such as Centrosolar America EP6 240 BW (240.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America EP6 240 BW
Centrosolar America
240.0 W Tie (0 W) 37.64 V 14.68% 88.6%
Centrosolar America EP6 240 SW
Centrosolar America
240.0 W Tie (0 W) 37.64 V 14.68% 88.6%
Hansol Technics Co Ltd HS240ME-V01
Hansol Technics Co Ltd
240.0 W Tie (0 W) 37.7 V 14.99% 89.3%
Heliene 60P240
Heliene
240.0 W Tie (0 W) 37.55 V 14.62% 89.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solarmax SEAP60-240?

Evaluate Solarmax SEAP60-240 (240.0 W STC, 37.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solarmax SEAP60-240 reaches 43.2 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 34 panels for an 8 kW build require 596 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (596 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solarmax SEAP60-240 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solarmax SEAP60-240 8 kW Residential Fit

Needs 34 modules (596 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America EP6 240 BW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 214.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solarmax SEAP60-240 by Solarmax grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

How many Solarmax SEAP60-240 panels fit on a 600 V winter solar string?

At -10 C (14 F), Solarmax SEAP60-240 cold Voc rises from 37.64 V to 41.96 V (beta_Voc -0.328%/C), capping a 600 V string at 14 panels (587.4 V).

How much roof area does an 8 kW array of Solarmax SEAP60-240 need?

An 8 kW DC system uses 34 Solarmax SEAP60-240 modules (8,160 W STC / 7,279 W PTC), covering roughly 596 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does Solarmax SEAP60-240 compare against Centrosolar America EP6 240 BW?

Solarmax SEAP60-240 outputs 240.0 W STC (37.64 V Voc, rank #20,160 of 21,677), while Centrosolar America EP6 240 BW delivers 240.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.