Skip to main content
WireAndSun
Calculators
CEC PV Module

Solarmax SEAP60-255 — CEC Solar Module Specifications

Manufacturer: Solarmax Registry: CEC Verified Engineering Specification

Solarmax SEAP60-255 is a 255.0 W STC (227.9 W PTC) Multi-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.66% efficiency, 38.8 V Voc at 25 C, and 43.25 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
255.0 W
PTC Wattage
227.9 W
Voc @ 25C
38.8 V
Efficiency
15.66%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solarmax SEAP60-255 Compare Against Peer CEC Listings?

Engineering position of Solarmax SEAP60-255 (255.0 W STC) vs. Changzhou Nesl Solartech DJ-255D/C-ST15 across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, Solarmax SEAP60-255 pairs typical 89.4% PTC-to-STC thermal output (227.9 W real-world rating) with 38.8 V nominal Voc. An 8 kW residential build (8,160 W DC, 7,293 W PTC) saves ~$2,042/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Changzhou Nesl Solartech DJ-255D/C-ST15 offers a 255.0 W alternative.

Where Does Solarmax SEAP60-255 Fall Across Listed CEC Models?

Plots Solarmax SEAP60-255 at 255.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solarmax SEAP60-255 (255.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolarmax SEAP60-25: 255.0 W

What Dataset Percentiles Define Solarmax SEAP60-255?

Benchmarks Solarmax SEAP60-255 on STC wattage, thermal PTC/STC retention, and 15.66 aperture conversion efficiency against CEC peers.

Solarmax SEAP60-255 Engineering BenchmarksPercentile comparison of Solarmax SEAP60-255 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage255.0 WPTC/STC Retention89.4%Module Efficiency15.66%

What Do the Dataset Ranks Show for Solarmax SEAP60-255?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Solarmax SEAP60-255 by Solarmax.

Rank #19,421 / 21,677

255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,715

15.66% Aperture Efficiency

Power density 156.5 W/m2 (4.25 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.25 V at -10 C (562.2 V string) and 44.53 V at -20 C (13 max).

8 kW Reference Array

32 Panels = 8,160 W STC

Occupies 52.1 m2 (561 sq ft) producing 7,293 W PTC; NEC 690.8 OCPD floor is 13.67 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.8 * (1 + (-0.328/100) * (-10 - 25)) = 43.25 V | OCPD = 1.56 * 8.76 = 13.67 A

Inputs from CEC Modules.csv for Solarmax SEAP60-255: Voc=38.8 V, beta_Voc=-0.328%/C, Isc=8.76 A, STC=255.0 W, Area=1.629 m2.

Result: 13 panels max on 600 V (562.2 V); 32 panels for 8 kW (561 sq ft).

What Are the Published CEC Specifications for Solarmax SEAP60-255?

Laboratory test ratings recorded for Solarmax SEAP60-255 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Solarmax SEAP60-255.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 255.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 227.9 W (89.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.76 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.59 V / 8.34 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.328 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.66% (1.629 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Solarmax SEAP60-255 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (561 sq ft at 8 kW), and estimated Year-1 electric bill offset for Solarmax SEAP60-255.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.12 kW 421 sq ft $1,532 $2,590
8 kW Class 32 8.16 kW 561 sq ft $2,042 $3,454
10 kW Class 40 10.2 kW 701 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This Solarmax Series?

Sibling wattage bins and frame colors grouped with Solarmax SEAP60-255 under Solarmax to prevent duplicate spec pages. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Solarmax SEAP60-255 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solarmax SEAP60-250 250.0 W 223.3 W 38.41 V 30.28 V 15.35%
Solarmax SEAP60-255 255.0 W 227.9 W 38.8 V 30.59 V 15.66%
Solarmax SEAP60-260 260.0 W 232.5 W 39.18 V 30.88 V 15.96%

How Many Solarmax SEAP60-255 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Solarmax SEAP60-255 (beta_Voc -0.328%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=38.8V and beta_Voc=-0.328%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.53 V 13 panels 578.9 V 22 panels
-10 C (14 F) 43.25 V 13 panels 562.2 V 23 panels
0 C (32 F) 41.98 V 14 panels 587.7 V 23 panels
25 C (77 F STC) 38.8 V 15 panels 582.0 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Solarmax SEAP60-255?

Closest cross-brand CEC competitors to Solarmax SEAP60-255 matched near 255.0 W STC and 38.8 V Voc, led by Changzhou Nesl Solartech DJ-255D/C-ST15.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Changzhou Nesl Solartech DJ-255D/C-ST15
Changzhou Nesl Solartech
255.0 W Tie (0 W) 38.19 V 15.61% 90.4%
GCL System Integration Technology Co Ltd GCL-P6/60255
GCL System Integration Technology Co Ltd
255.0 W Tie (0 W) 37.7 V 15.67% 90.4%
Advance Power API-M255
Advance Power
255.0 W Tie (0 W) 37.68 V 15.57% 89.5%
Eoplly New Energy Technology EP156P/60-255S AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.68 V 15.6% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solarmax SEAP60-255?

Evaluate Solarmax SEAP60-255 (255.0 W STC, 38.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solarmax SEAP60-255 reaches 44.53 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 561 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (561 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solarmax SEAP60-255 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solarmax SEAP60-255 8 kW Residential Fit

Needs 32 modules (561 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Changzhou Nesl Solartech DJ-255D/C-ST15.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 227.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solarmax SEAP60-255 by Solarmax grounded in CEC test data and NEC 690.7/690.8 limits. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

What fuse or breaker size does NEC 690.8 require for Solarmax SEAP60-255?

Multiplying Solarmax SEAP60-255's 8.76 A short-circuit current by 1.56 equals 13.67 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Solarmax SEAP60-255 before finalizing component orders.

Can Solarmax SEAP60-255 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.25 V cold Voc at 14 F and handles 8.76 A Isc; string inverters cap Solarmax SEAP60-255 at 13 panels on 600 V.

Is Solarmax SEAP60-255 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solarmax SEAP60-255 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.