Centrosolar America EP6 240 SW is a 240.0 W STC (212.7 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.68% efficiency, 37.64 V Voc at 25 C, and 42.04 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 240.0 W
- PTC Wattage
- 212.7 W
- Voc @ 25C
- 37.64 V
- Efficiency
- 14.68%
How Does Centrosolar America EP6 240 SW Compare Against Peer CEC Listings?
How Centrosolar America Centrosolar America EP6 240 SW handles rooftop heat (212.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Centrosolar America EP6 240 SW exhibits 8.82 A short-circuit current, requiring a 13.76 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,160 of 21,677 (38.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 55.6 m2 for an 8 kW system (42 panels for 10 kW). Lower 37.64 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Centrosolar America EP6 240 SW Fall Across Listed CEC Models?
Where Centrosolar America EP6 240 SW (240.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Centrosolar America EP6 240 SW?
Percentile placement of Centrosolar America EP6 240 SW across power density (146.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Centrosolar America EP6 240 SW?
Four critical engineering numbers homeowners and solar installers check first when reviewing Centrosolar America EP6 240 SW specifications.
240.0 W STC · Higher Than 6.1%
240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.68% Aperture Efficiency
Power density 146.8 W/m2 (5.23 percentage points below 19.91% CEC median). PTC/STC ratio: 88.6% (rank #21,091).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.04 V at -10 C (588.6 V string) and 43.3 V at -20 C (13 max).
34 Panels = 8,160 W STC
Occupies 55.6 m2 (598 sq ft) producing 7,232 W PTC; NEC 690.8 OCPD floor is 13.76 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.64 * (1 + (-0.334/100) * (-10 - 25)) = 42.04 V | OCPD = 1.56 * 8.82 = 13.76 A
Inputs from CEC Modules.csv for Centrosolar America EP6 240 SW: Voc=37.64 V, beta_Voc=-0.334%/C, Isc=8.82 A, STC=240.0 W, Area=1.635 m2.
Result: 14 panels max on 600 V (588.6 V); 34 panels for 8 kW (598 sq ft).
What Are the Published CEC Specifications for Centrosolar America EP6 240 SW?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Centrosolar America EP6 240 SW.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 212.7 W (88.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.64 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.82 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.9 V / 8.2 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.334 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.68% (1.635 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Centrosolar America EP6 240 SW Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Centrosolar America EP6 240 SW (240.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.0 kW | 440 sq ft | $1,502 | $2,539 |
| 8 kW Class | 34 | 8.16 kW | 598 sq ft | $2,042 | $3,454 |
| 10 kW Class | 42 | 10.08 kW | 739 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?
All closely matched Centrosolar America wattages and cosmetic trims sharing the Centrosolar America EP6 240 SW architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Centrosolar America EP6 235 SW | 235.0 W | 208.1 W | 37.44 V | 29.74 V | 14.37% |
| Centrosolar America EP6 240 SW | 240.0 W | 212.7 W | 37.64 V | 29.9 V | 14.68% |
| Centrosolar America EP6 245 SW | 245.0 W | 217.2 W | 37.64 V | 29.9 V | 14.99% |
How Many Centrosolar America EP6 240 SW Modules Fit in a Cold-Weather String?
Maximum series module counts for Centrosolar America EP6 240 SW from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.3 V | 13 panels | 562.9 V | 23 panels |
| -10 C (14 F) | 42.04 V | 14 panels | 588.6 V | 23 panels |
| 0 C (32 F) | 40.78 V | 14 panels | 570.9 V | 24 panels |
| 25 C (77 F STC) | 37.64 V | 15 panels | 564.6 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Centrosolar America EP6 240 SW?
Alternative CEC solar modules from competing brands near Centrosolar America EP6 240 SW (240.0 W), including Hansol Technics Co Ltd HS240ME-V01.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS240ME-V01 Hansol Technics Co Ltd |
240.0 W | Tie (0 W) | 37.7 V | 14.99% | 89.3% |
| Heliene 60P240 Heliene |
240.0 W | Tie (0 W) | 37.55 V | 14.62% | 89.2% |
| AXITEC AC-240M/156-60S AXITEC |
240.0 W | Tie (0 W) | 37.47 V | 14.79% | 90.4% |
| AXITEC AC-240P/156-60B AXITEC |
240.0 W | Tie (0 W) | 37.4 V | 14.79% | 89.5% |
What Are the Design Limits and Best-Fit Uses for Centrosolar America EP6 240 SW?
Evaluate Centrosolar America EP6 240 SW (240.0 W STC, 37.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America EP6 240 SW reaches 43.3 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 598 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (598 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America EP6 240 SW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Centrosolar America EP6 240 SW 8 kW Residential Fit
Needs 34 modules (598 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Hansol Technics Co Ltd HS240ME-V01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 212.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Centrosolar America EP6 240 SW by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Centrosolar America EP6 240 SW PTC wattage (212.7 W) lower than STC (240.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 212.7 W PTC (88.6% retention) across Centrosolar America EP6 240 SW's 1.635 m2 aperture.
Who should skip Centrosolar America EP6 240 SW on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 34 Centrosolar America EP6 240 SW panels (598 sq ft) leave unusable roof gaps vs. Hansol Technics Co Ltd HS240ME-V01.
What is the 1,000 V commercial string limit for Centrosolar America EP6 240 SW?
On 1,000 V commercial inverters at -10 C (42.04 V cold Voc), Centrosolar America EP6 240 SW fits up to 23 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)