AXITEC AC-240M/156-60S — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-240M/156-60S is a 240.0 W STC (217.0 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.79% efficiency, 37.47 V Voc at 25 C, and 42.22 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
240.0 W
PTC Wattage
217.0 W
Voc @ 25C
37.47 V
Efficiency
14.79%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-240M/156-60S Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-240M/156-60S (Mono-c-Si) residential solar systems.

AXITEC AC-240M/156-60S delivers 147.9 W/m2 (5.12 percentage points below 19.91% CEC median) and typical 90.4% PTC-to-STC thermal output (217.0 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (594 sq ft). At -4 F (-20 C), string voltage climbs to 43.57 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Heliene 60P240 (240.0 W).

Where Does AXITEC AC-240M/156-60S Fall Across Listed CEC Models?

Comparison of AXITEC AC-240M/156-60S (240.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-240M/156-60S (240.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-240M/156: 240.0 W

What Dataset Percentiles Define AXITEC AC-240M/156-60S?

Relative ranking of AXITEC AC-240M/156-60S across nameplate watts, 90.4% PTC thermal ratio, and module aperture efficiency. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

AXITEC AC-240M/156-60S Engineering BenchmarksPercentile comparison of AXITEC AC-240M/156-60S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage240.0 WPTC/STC Retention90.4%Module Efficiency14.79%

What Do the Dataset Ranks Show for AXITEC AC-240M/156-60S?

Summary of AXITEC AC-240M/156-60S output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.

Rank #20,160 / 21,677

240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,049

14.79% Aperture Efficiency

Power density 147.9 W/m2 (5.12 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.22 V at -10 C (591.1 V string) and 43.57 V at -20 C (13 max).

8 kW Reference Array

34 Panels = 8,160 W STC

Occupies 55.2 m2 (594 sq ft) producing 7,378 W PTC; NEC 690.8 OCPD floor is 13.31 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.47 * (1 + (-0.362/100) * (-10 - 25)) = 42.22 V | OCPD = 1.56 * 8.53 = 13.31 A

Inputs from CEC Modules.csv for AXITEC AC-240M/156-60S: Voc=37.47 V, beta_Voc=-0.362%/C, Isc=8.53 A, STC=240.0 W, Area=1.623 m2.

Result: 14 panels max on 600 V (591.1 V); 34 panels for 8 kW (594 sq ft).

What Are the Published CEC Specifications for AXITEC AC-240M/156-60S?

Complete CEC test sheet for AXITEC AC-240M/156-60S including Isc (8.53 A), Voc (37.47 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-240M/156-60S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 240.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 217.0 W (90.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.47 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.53 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.23 V / 7.94 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.362 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.79% (1.623 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many AXITEC AC-240M/156-60S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-240M/156-60S.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.0 kW 437 sq ft $1,502 $2,539
8 kW Class 34 8.16 kW 594 sq ft $2,042 $3,454
10 kW Class 42 10.08 kW 734 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-240M/156-60S series guide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the AXITEC AC-240M/156-60S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-230M/156-60S 230.0 W 207.7 W 37.06 V 29.49 V 14.17%
AXITEC AC-235M/156-60S 235.0 W 212.3 W 37.26 V 29.86 V 14.48%
AXITEC AC-240M/156-60S 240.0 W 217.0 W 37.47 V 30.23 V 14.79%
AXITEC AC-245M/156-60S 245.0 W 221.6 W 37.67 V 30.59 V 15.1%

How Many AXITEC AC-240M/156-60S Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for AXITEC AC-240M/156-60S (37.47 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.47V and beta_Voc=-0.362%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.57 V 13 panels 566.4 V 22 panels
-10 C (14 F) 42.22 V 14 panels 591.1 V 23 panels
0 C (32 F) 40.86 V 14 panels 572.0 V 24 panels
25 C (77 F STC) 37.47 V 16 panels 599.5 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-240M/156-60S?

Four comparable CEC modules such as Heliene 60P240 (240.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 60P240
Heliene
240.0 W Tie (0 W) 37.55 V 14.62% 89.2%
Centrosolar America EP6 240 BW
Centrosolar America
240.0 W Tie (0 W) 37.64 V 14.68% 88.6%
Centrosolar America EP6 240 SW
Centrosolar America
240.0 W Tie (0 W) 37.64 V 14.68% 88.6%
CSI Solar Co Ltd CS6P-240M
CSI Solar Co Ltd
240.0 W Tie (0 W) 37.3 V 15.5% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-240M/156-60S?

Evaluate AXITEC AC-240M/156-60S (240.0 W STC, 37.47 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-240M/156-60S reaches 43.57 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 34 panels for an 8 kW build require 594 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (594 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-240M/156-60S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-240M/156-60S 8 kW Residential Fit

Needs 34 modules (594 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Heliene 60P240.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 217.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-240M/156-60S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many AXITEC AC-240M/156-60S panels fit on a 600 V winter solar string?

At -10 C (14 F), AXITEC AC-240M/156-60S cold Voc rises from 37.47 V to 42.22 V (beta_Voc -0.362%/C), capping a 600 V string at 14 panels (591.1 V).

How much roof area does an 8 kW array of AXITEC AC-240M/156-60S need?

An 8 kW DC system uses 34 AXITEC AC-240M/156-60S modules (8,160 W STC / 7,378 W PTC), covering roughly 594 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does AXITEC AC-240M/156-60S compare against Heliene 60P240?

AXITEC AC-240M/156-60S outputs 240.0 W STC (37.47 V Voc, rank #20,160 of 21,677), while Heliene 60P240 delivers 240.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.