Skip to main content
WireAndSun
Calculators
CEC PV Module

Centrosolar America EP6 240 BW — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America EP6 240 BW is a 240.0 W STC (212.7 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.68% efficiency, 37.64 V Voc at 25 C, and 42.04 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
240.0 W
PTC Wattage
212.7 W
Voc @ 25C
37.64 V
Efficiency
14.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America EP6 240 BW Compare Against Peer CEC Listings?

Engineering position of Centrosolar America EP6 240 BW (240.0 W STC) vs. Hansol Technics Co Ltd HS240ME-V01 across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, Centrosolar America EP6 240 BW pairs typical 88.6% PTC-to-STC thermal output (212.7 W real-world rating) with 37.64 V nominal Voc. An 8 kW residential build (8,160 W DC, 7,232 W PTC) saves ~$2,042/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Hansol Technics Co Ltd HS240ME-V01 offers a 240.0 W alternative.

Where Does Centrosolar America EP6 240 BW Fall Across Listed CEC Models?

Plots Centrosolar America EP6 240 BW at 240.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America EP6 240 BW (240.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 240.0 W

What Dataset Percentiles Define Centrosolar America EP6 240 BW?

Benchmarks Centrosolar America EP6 240 BW on STC wattage, thermal PTC/STC retention, and 14.68 aperture conversion efficiency against CEC peers.

Centrosolar America EP6 240 BW Engineering BenchmarksPercentile comparison of Centrosolar America EP6 240 BW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage240.0 WPTC/STC Retention88.6%Module Efficiency14.68%

What Do the Dataset Ranks Show for Centrosolar America EP6 240 BW?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Centrosolar America EP6 240 BW by Centrosolar America.

Rank #20,160 / 21,677

240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,210

14.68% Aperture Efficiency

Power density 146.8 W/m2 (5.23 percentage points below 19.91% CEC median). PTC/STC ratio: 88.6% (rank #21,091).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.04 V at -10 C (588.6 V string) and 43.3 V at -20 C (13 max).

8 kW Reference Array

34 Panels = 8,160 W STC

Occupies 55.6 m2 (598 sq ft) producing 7,232 W PTC; NEC 690.8 OCPD floor is 13.76 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.64 * (1 + (-0.334/100) * (-10 - 25)) = 42.04 V | OCPD = 1.56 * 8.82 = 13.76 A

Inputs from CEC Modules.csv for Centrosolar America EP6 240 BW: Voc=37.64 V, beta_Voc=-0.334%/C, Isc=8.82 A, STC=240.0 W, Area=1.635 m2.

Result: 14 panels max on 600 V (588.6 V); 34 panels for 8 kW (598 sq ft).

What Are the Published CEC Specifications for Centrosolar America EP6 240 BW?

Laboratory test ratings recorded for Centrosolar America EP6 240 BW (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America EP6 240 BW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 240.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 212.7 W (88.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.64 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.82 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.9 V / 8.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.334 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.68% (1.635 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Centrosolar America EP6 240 BW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (598 sq ft at 8 kW), and estimated Year-1 electric bill offset for Centrosolar America EP6 240 BW.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.0 kW 440 sq ft $1,502 $2,539
8 kW Class 34 8.16 kW 598 sq ft $2,042 $3,454
10 kW Class 42 10.08 kW 739 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Sibling wattage bins and frame colors grouped with Centrosolar America EP6 240 BW under Centrosolar America to prevent duplicate spec pages.

Sibling CEC listings grouped into the Centrosolar America EP6 240 BW wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America EP6 235 BW 235.0 W 208.1 W 37.44 V 29.74 V 14.37%
Centrosolar America EP6 240 BW 240.0 W 212.7 W 37.64 V 29.9 V 14.68%
Centrosolar America EP6 245 BW 245.0 W 217.2 W 37.64 V 29.9 V 14.99%

How Many Centrosolar America EP6 240 BW Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Centrosolar America EP6 240 BW (beta_Voc -0.334%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.64V and beta_Voc=-0.334%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.3 V 13 panels 562.9 V 23 panels
-10 C (14 F) 42.04 V 14 panels 588.6 V 23 panels
0 C (32 F) 40.78 V 14 panels 570.9 V 24 panels
25 C (77 F STC) 37.64 V 15 panels 564.6 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America EP6 240 BW?

Closest cross-brand CEC competitors to Centrosolar America EP6 240 BW matched near 240.0 W STC and 37.64 V Voc, led by Hansol Technics Co Ltd HS240ME-V01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hansol Technics Co Ltd HS240ME-V01
Hansol Technics Co Ltd
240.0 W Tie (0 W) 37.7 V 14.99% 89.3%
Heliene 60P240
Heliene
240.0 W Tie (0 W) 37.55 V 14.62% 89.2%
AXITEC AC-240M/156-60S
AXITEC
240.0 W Tie (0 W) 37.47 V 14.79% 90.4%
AXITEC AC-240P/156-60B
AXITEC
240.0 W Tie (0 W) 37.4 V 14.79% 89.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America EP6 240 BW?

Evaluate Centrosolar America EP6 240 BW (240.0 W STC, 37.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America EP6 240 BW reaches 43.3 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 34 panels for an 8 kW build require 598 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (598 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America EP6 240 BW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America EP6 240 BW 8 kW Residential Fit

Needs 34 modules (598 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Hansol Technics Co Ltd HS240ME-V01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 212.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America EP6 240 BW by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Centrosolar America EP6 240 BW?

Multiplying Centrosolar America EP6 240 BW's 8.82 A short-circuit current by 1.56 equals 13.76 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Centrosolar America EP6 240 BW pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.04 V cold Voc at 14 F and handles 8.82 A Isc; string inverters cap Centrosolar America EP6 240 BW at 14 panels on 600 V.

Is Centrosolar America EP6 240 BW eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Centrosolar America EP6 240 BW rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.