AXITEC AC-240P/156-60B is a 240.0 W STC (214.9 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.79% efficiency, 37.4 V Voc at 25 C, and 42.44 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 240.0 W
- PTC Wattage
- 214.9 W
- Voc @ 25C
- 37.4 V
- Efficiency
- 14.79%
How Does AXITEC AC-240P/156-60B Compare Against Peer CEC Listings?
Engineering position of AXITEC AC-240P/156-60B (240.0 W STC) vs. CSI Solar Co Ltd CS6P-240M across 1,407 CEC Multi-c-Si solar modules.
Ranking #20,160 across 21,677 CEC solar panels (below all-CEC median; higher than 6.1% of peers), AXITEC AC-240P/156-60B operates as a compact residential or specialty off-grid module sitting 38.8 W below the 278.8 W Multi-c-Si median. Lower 37.4 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 89.5% PTC-to-STC thermal output (214.9 W real-world rating), 34 panels occupy 594 sq ft and offset roughly $2,042/yr at average US rates (or $3,454/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does AXITEC AC-240P/156-60B Fall Across Listed CEC Models?
Plots AXITEC AC-240P/156-60B at 240.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-240P/156-60B?
Benchmarks AXITEC AC-240P/156-60B on STC wattage, thermal PTC/STC retention, and 14.79 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for AXITEC AC-240P/156-60B?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-240P/156-60B by AXITEC.
240.0 W STC · Higher Than 6.1%
240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.79% Aperture Efficiency
Power density 147.9 W/m2 (5.12 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.44 V at -10 C (594.2 V string) and 43.88 V at -20 C (13 max).
34 Panels = 8,160 W STC
Occupies 55.2 m2 (594 sq ft) producing 7,307 W PTC; NEC 690.8 OCPD floor is 13.18 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.4 * (1 + (-0.385/100) * (-10 - 25)) = 42.44 V | OCPD = 1.56 * 8.45 = 13.18 A
Inputs from CEC Modules.csv for AXITEC AC-240P/156-60B: Voc=37.4 V, beta_Voc=-0.385%/C, Isc=8.45 A, STC=240.0 W, Area=1.623 m2.
Result: 14 panels max on 600 V (594.2 V); 34 panels for 8 kW (594 sq ft).
What Are the Published CEC Specifications for AXITEC AC-240P/156-60B?
Laboratory test ratings recorded for AXITEC AC-240P/156-60B (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 214.9 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.45 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.0 V / 8.0 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.385 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.79% (1.623 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many AXITEC AC-240P/156-60B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (594 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-240P/156-60B.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.0 kW | 437 sq ft | $1,502 | $2,539 |
| 8 kW Class | 34 | 8.16 kW | 594 sq ft | $2,042 | $3,454 |
| 10 kW Class | 42 | 10.08 kW | 734 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Sibling wattage bins and frame colors grouped with AXITEC AC-240P/156-60B under AXITEC to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-235P/156-60B | 235.0 W | 210.3 W | 37.3 V | 29.55 V | 14.48% |
| AXITEC AC-240P/156-60B | 240.0 W | 214.9 W | 37.4 V | 30.0 V | 14.79% |
How Many AXITEC AC-240P/156-60B Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for AXITEC AC-240P/156-60B (beta_Voc -0.385%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.88 V | 13 panels | 570.4 V | 22 panels |
| -10 C (14 F) | 42.44 V | 14 panels | 594.2 V | 23 panels |
| 0 C (32 F) | 41.0 V | 14 panels | 574.0 V | 24 panels |
| 25 C (77 F STC) | 37.4 V | 16 panels | 598.4 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-240P/156-60B?
Closest cross-brand CEC competitors to AXITEC AC-240P/156-60B matched near 240.0 W STC and 37.4 V Voc, led by CSI Solar Co Ltd CS6P-240M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6P-240M CSI Solar Co Ltd |
240.0 W | Tie (0 W) | 37.3 V | 15.5% | 90.5% |
| CSI Solar Co Ltd CS6P-240MX CSI Solar Co Ltd |
240.0 W | Tie (0 W) | 37.3 V | 15.5% | 88.3% |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240Q Hanwha Qcells (Qidong) Co Ltd |
240.0 W | Tie (0 W) | 37.3 V | 14.53% | 89.0% |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240QB Hanwha Qcells (Qidong) Co Ltd |
240.0 W | Tie (0 W) | 37.3 V | 14.53% | 89.0% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-240P/156-60B?
Evaluate AXITEC AC-240P/156-60B (240.0 W STC, 37.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-240P/156-60B reaches 43.88 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 594 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (594 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-240P/156-60B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-240P/156-60B 8 kW Residential Fit
Needs 34 modules (594 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS6P-240M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 214.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-240P/156-60B by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-240P/156-60B panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-240P/156-60B cold Voc rises from 37.4 V to 42.44 V (beta_Voc -0.385%/C), capping a 600 V string at 14 panels (594.2 V).
How much roof area does an 8 kW array of AXITEC AC-240P/156-60B need?
An 8 kW DC system uses 34 AXITEC AC-240P/156-60B modules (8,160 W STC / 7,307 W PTC), covering roughly 594 sq ft and saving ~$2,042/yr at 18.54 c/kWh.
How does AXITEC AC-240P/156-60B compare against CSI Solar Co Ltd CS6P-240M?
AXITEC AC-240P/156-60B outputs 240.0 W STC (37.4 V Voc, rank #20,160 of 21,677), while CSI Solar Co Ltd CS6P-240M delivers 240.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)