Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd CS6P-240MX is a 240.0 W STC (212.0 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 15.5% efficiency, 37.3 V Voc at 25 C, and 41.87 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
240.0 W
PTC Wattage
212.0 W
Voc @ 25C
37.3 V
Efficiency
15.5%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd CS6P-240MX Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for CSI Solar Co Ltd CS6P-240MX (Mono-c-Si) residential solar systems.

CSI Solar Co Ltd CS6P-240MX delivers 154.9 W/m2 (4.41 percentage points below 19.91% CEC median) and typical 88.3% PTC-to-STC thermal output (212.0 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (567 sq ft). At -4 F (-20 C), string voltage climbs to 43.17 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240Q (240.0 W).

Where Does CSI Solar Co Ltd CS6P-240MX Fall Across Listed CEC Models?

Comparison of CSI Solar Co Ltd CS6P-240MX (240.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CSI Solar Co Ltd CS6P-240MX (240.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCSI Solar Co Ltd C: 240.0 W

What Dataset Percentiles Define CSI Solar Co Ltd CS6P-240MX?

Relative ranking of CSI Solar Co Ltd CS6P-240MX across nameplate watts, 88.3% PTC thermal ratio, and module aperture efficiency.

CSI Solar Co Ltd CS6P-240MX Engineering BenchmarksPercentile comparison of CSI Solar Co Ltd CS6P-240MX wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage240.0 WPTC/STC Retention88.3%Module Efficiency15.5%

What Do the Dataset Ranks Show for CSI Solar Co Ltd CS6P-240MX?

Summary of CSI Solar Co Ltd CS6P-240MX output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.

Rank #20,160 / 21,677

240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,933

15.5% Aperture Efficiency

Power density 154.9 W/m2 (4.41 percentage points below 19.91% CEC median). PTC/STC ratio: 88.3% (rank #21,245).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.87 V at -10 C (586.2 V string) and 43.17 V at -20 C (13 max).

8 kW Reference Array

34 Panels = 8,160 W STC

Occupies 52.7 m2 (567 sq ft) producing 7,208 W PTC; NEC 690.8 OCPD floor is 13.2 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.3 * (1 + (-0.35/100) * (-10 - 25)) = 41.87 V | OCPD = 1.56 * 8.46 = 13.2 A

Inputs from CEC Modules.csv for CSI Solar Co Ltd CS6P-240MX: Voc=37.3 V, beta_Voc=-0.35%/C, Isc=8.46 A, STC=240.0 W, Area=1.549 m2.

Result: 14 panels max on 600 V (586.2 V); 34 panels for 8 kW (567 sq ft).

What Are the Published CEC Specifications for CSI Solar Co Ltd CS6P-240MX?

Complete CEC test sheet for CSI Solar Co Ltd CS6P-240MX including Isc (8.46 A), Voc (37.3 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd CS6P-240MX.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 240.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 212.0 W (88.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.46 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.2 V / 7.95 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.35 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.5% (1.549 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many CSI Solar Co Ltd CS6P-240MX Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using CSI Solar Co Ltd CS6P-240MX.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.0 kW 417 sq ft $1,502 $2,539
8 kW Class 34 8.16 kW 567 sq ft $2,042 $3,454
10 kW Class 42 10.08 kW 700 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?

Related CSI Solar Co Ltd power steps and black/silver trims consolidated into this CSI Solar Co Ltd CS6P-240MX series guide.

Sibling CEC listings grouped into the CSI Solar Co Ltd CS6P-240MX wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
CSI Solar Co Ltd CS6P-230MX 230.0 W 202.9 W 37.1 V 29.9 V 14.85%
CSI Solar Co Ltd CS6P-235MX 235.0 W 207.5 W 37.2 V 30.1 V 15.17%
CSI Solar Co Ltd CS6P-240MX 240.0 W 212.0 W 37.3 V 30.2 V 15.5%
CSI Solar Co Ltd CS6P-245MX 245.0 W 221.7 W 37.4 V 30.3 V 15.82%

How Many CSI Solar Co Ltd CS6P-240MX Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for CSI Solar Co Ltd CS6P-240MX (37.3 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.3V and beta_Voc=-0.35%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.17 V 13 panels 561.2 V 23 panels
-10 C (14 F) 41.87 V 14 panels 586.2 V 23 panels
0 C (32 F) 40.56 V 14 panels 567.8 V 24 panels
25 C (77 F STC) 37.3 V 16 panels 596.8 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS6P-240MX?

Four comparable CEC modules such as Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240Q (240.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240Q
Hanwha Qcells (Qidong) Co Ltd
240.0 W Tie (0 W) 37.3 V 14.53% 89.0%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240QB
Hanwha Qcells (Qidong) Co Ltd
240.0 W Tie (0 W) 37.3 V 14.53% 89.0%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240QW
Hanwha Qcells (Qidong) Co Ltd
240.0 W Tie (0 W) 37.3 V 14.53% 89.0%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-240Q
Hanwha Qcells (Qidong) Co Ltd
240.0 W Tie (0 W) 37.3 V 14.53% 89.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS6P-240MX?

Evaluate CSI Solar Co Ltd CS6P-240MX (240.0 W STC, 37.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS6P-240MX reaches 43.17 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 34 panels for an 8 kW build require 567 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (567 sq ft).
  • 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS6P-240MX carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CSI Solar Co Ltd CS6P-240MX 8 kW Residential Fit

Needs 34 modules (567 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240Q.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 212.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CSI Solar Co Ltd CS6P-240MX by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many CSI Solar Co Ltd CS6P-240MX panels fit on a 600 V winter solar string?

At -10 C (14 F), CSI Solar Co Ltd CS6P-240MX cold Voc rises from 37.3 V to 41.87 V (beta_Voc -0.35%/C), capping a 600 V string at 14 panels (586.2 V).

How much roof area does an 8 kW array of CSI Solar Co Ltd CS6P-240MX need?

An 8 kW DC system uses 34 CSI Solar Co Ltd CS6P-240MX modules (8,160 W STC / 7,208 W PTC), covering roughly 567 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does CSI Solar Co Ltd CS6P-240MX compare against Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240Q?

CSI Solar Co Ltd CS6P-240MX outputs 240.0 W STC (37.3 V Voc, rank #20,160 of 21,677), while Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240Q delivers 240.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.