Shanghai ST Solar STM240-96 is a 240.0 W STC (214.0 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.22% efficiency, 60.0 V Voc at 25 C, and 67.14 V cold Voc at -10 C (8 panels max per 600 V string).
- STC Wattage
- 240.0 W
- PTC Wattage
- 214.0 W
- Voc @ 25C
- 60.0 V
- Efficiency
- 14.22%
How Does Shanghai ST Solar STM240-96 Compare Against Peer CEC Listings?
Engineering position of Shanghai ST Solar STM240-96 (240.0 W STC) vs. Exeltech AM24-1-B-6-0-00 across 5,889 CEC Mono-c-Si solar modules.
Ranking #20,160 across 21,677 CEC solar panels (below all-CEC median; higher than 6.1% of peers), Shanghai ST Solar STM240-96 operates as a compact residential or specialty off-grid module sitting 170.0 W below the 410.0 W Mono-c-Si median. Higher 60.0 V open-circuit voltage caps 600 V residential strings at 8 panels at 14 F (-10 C). With typical 89.2% PTC-to-STC thermal output (214.0 W real-world rating), 34 panels occupy 617 sq ft and offset roughly $2,042/yr at average US rates (or $3,454/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Shanghai ST Solar STM240-96 Fall Across Listed CEC Models?
Plots Shanghai ST Solar STM240-96 at 240.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Shanghai ST Solar STM240-96?
Benchmarks Shanghai ST Solar STM240-96 on STC wattage, thermal PTC/STC retention, and 14.22 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Shanghai ST Solar STM240-96?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Shanghai ST Solar STM240-96 by Shanghai ST Solar.
240.0 W STC · Higher Than 6.1%
240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.22% Aperture Efficiency
Power density 142.3 W/m2 (5.69 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).
8 Panels Max @ -10 C (600 V)
Cold Voc reaches 67.14 V at -10 C (537.1 V string) and 69.18 V at -20 C (8 max).
34 Panels = 8,160 W STC
Occupies 57.4 m2 (617 sq ft) producing 7,276 W PTC; NEC 690.8 OCPD floor is 8.67 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 60.0 * (1 + (-0.34/100) * (-10 - 25)) = 67.14 V | OCPD = 1.56 * 5.56 = 8.67 A
Inputs from CEC Modules.csv for Shanghai ST Solar STM240-96: Voc=60.0 V, beta_Voc=-0.34%/C, Isc=5.56 A, STC=240.0 W, Area=1.687 m2.
Result: 8 panels max on 600 V (537.1 V); 34 panels for 8 kW (617 sq ft).
What Are the Published CEC Specifications for Shanghai ST Solar STM240-96?
Laboratory test ratings recorded for Shanghai ST Solar STM240-96 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 214.0 W (89.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 60.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 48.0 V / 5.0 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.22% (1.687 m2) | Array roof footprint density |
| Cell Count & Technology | 96 cells (Mono-c-Si) | Monofacial backsheet |
How Many Shanghai ST Solar STM240-96 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (617 sq ft at 8 kW), and estimated Year-1 electric bill offset for Shanghai ST Solar STM240-96.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.0 kW | 454 sq ft | $1,502 | $2,539 |
| 8 kW Class | 34 | 8.16 kW | 617 sq ft | $2,042 | $3,454 |
| 10 kW Class | 42 | 10.08 kW | 763 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Shanghai ST Solar Series?
Sibling wattage bins and frame colors grouped with Shanghai ST Solar STM240-96 under Shanghai ST Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Shanghai ST Solar STM225-96 | 225.0 W | 200.3 W | 58.75 V | 47.0 V | 13.33% |
| Shanghai ST Solar STM235-96 | 235.0 W | 209.4 W | 58.8 V | 47.04 V | 13.93% |
| Shanghai ST Solar STM240-96 | 240.0 W | 214.0 W | 60.0 V | 48.0 V | 14.22% |
| Shanghai ST Solar STM245-96 | 245.0 W | 218.6 W | 60.0 V | 48.0 V | 14.52% |
How Many Shanghai ST Solar STM240-96 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Shanghai ST Solar STM240-96 (beta_Voc -0.34%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 69.18 V | 8 panels | 553.4 V | 14 panels |
| -10 C (14 F) | 67.14 V | 8 panels | 537.1 V | 14 panels |
| 0 C (32 F) | 65.1 V | 9 panels | 585.9 V | 15 panels |
| 25 C (77 F STC) | 60.0 V | 10 panels | 600.0 V | 16 panels |
Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STM240-96?
Closest cross-brand CEC competitors to Shanghai ST Solar STM240-96 matched near 240.0 W STC and 60.0 V Voc, led by Exeltech AM24-1-B-6-0-00.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Exeltech AM24-1-B-6-0-00 Exeltech |
240.0 W | Tie (0 W) | 59.5 V | 14.12% | 88.3% |
| Grape Solar GS-S-240-CS Grape Solar |
240.0 W | Tie (0 W) | 59.3 V | 14.12% | 91.1% |
| Grape Solar GS-S-220-CS Grape Solar |
220.0 W | -20.0 W | 59.4 V | 12.94% | 91.0% |
| Gintung Energy ASEC-245G6M Gintung Energy |
245.0 W | +5.0 W | 43.39 V | 12.53% | 89.1% |
What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STM240-96?
Evaluate Shanghai ST Solar STM240-96 (240.0 W STC, 60.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STM240-96 reaches 69.18 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 617 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (617 sq ft).
- 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STM240-96 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Shanghai ST Solar STM240-96 8 kW Residential Fit
Needs 34 modules (617 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Exeltech AM24-1-B-6-0-00.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 214.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Shanghai ST Solar STM240-96 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Shanghai ST Solar STM240-96 panels fit on a 600 V winter solar string?
At -10 C (14 F), Shanghai ST Solar STM240-96 cold Voc rises from 60.0 V to 67.14 V (beta_Voc -0.34%/C), capping a 600 V string at 8 panels (537.1 V).
How much roof area does an 8 kW array of Shanghai ST Solar STM240-96 need?
An 8 kW DC system uses 34 Shanghai ST Solar STM240-96 modules (8,160 W STC / 7,276 W PTC), covering roughly 617 sq ft and saving ~$2,042/yr at 18.54 c/kWh.
How does Shanghai ST Solar STM240-96 compare against Exeltech AM24-1-B-6-0-00?
Shanghai ST Solar STM240-96 outputs 240.0 W STC (60.0 V Voc, rank #20,160 of 21,677), while Exeltech AM24-1-B-6-0-00 delivers 240.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)