Skip to main content
WireAndSun
Calculators
CEC PV Module

ReCreate DS-MERCURY-485TC — CEC Solar Module Specifications

Manufacturer: ReCreate Registry: CEC Verified Engineering Specification

ReCreate DS-MERCURY-485TC is a 485.0 W STC (456.6 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 23.1% efficiency, 42.85 V Voc at 25 C, and 46.28 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
485.0 W
PTC Wattage
456.6 W
Voc @ 25C
42.85 V
Efficiency
23.1%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ReCreate DS-MERCURY-485TC Compare Against Peer CEC Listings?

Engineering position of ReCreate DS-MERCURY-485TC (485.0 W STC) vs. Hanersun Energy Co Ltd HN18N-60HT485W across 5,889 CEC Mono-c-Si solar modules.

Ranking #4,730 across 21,677 CEC solar panels (top 22.2%; higher than 77.8% of peers), ReCreate DS-MERCURY-485TC operates as a modern high-density residential and light-commercial module sitting 75.0 W above the 410.0 W Mono-c-Si median. Mid-range 42.85 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F. With strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677), 17 panels occupy 384 sq ft and offset roughly $2,062/yr at average US rates (or $3,487/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does ReCreate DS-MERCURY-485TC Fall Across Listed CEC Models?

Plots ReCreate DS-MERCURY-485TC at 485.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where ReCreate DS-MERCURY-485TC (485.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCReCreate DS-MERCUR: 485.0 W

What Dataset Percentiles Define ReCreate DS-MERCURY-485TC?

Benchmarks ReCreate DS-MERCURY-485TC on STC wattage, thermal PTC/STC retention, and 23.1 aperture conversion efficiency against CEC peers.

ReCreate DS-MERCURY-485TC Engineering BenchmarksPercentile comparison of ReCreate DS-MERCURY-485TC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage485.0 WPTC/STC Retention94.1%Module Efficiency23.1%

What Do the Dataset Ranks Show for ReCreate DS-MERCURY-485TC?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for ReCreate DS-MERCURY-485TC by ReCreate.

Rank #4,730 / 21,677

Top 22.2% STC Output

485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #985

23.1% Aperture Efficiency

Power density 231.0 W/m2 (3.19 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.28 V at -10 C (555.4 V string) and 47.27 V at -20 C (12 max).

8 kW Reference Array

17 Panels = 8,245 W STC

Occupies 35.7 m2 (384 sq ft) producing 7,762 W PTC; NEC 690.8 OCPD floor is 22.46 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.85 * (1 + (-0.229/100) * (-10 - 25)) = 46.28 V | OCPD = 1.56 * 14.4 = 22.46 A

Inputs from CEC Modules.csv for ReCreate DS-MERCURY-485TC: Voc=42.85 V, beta_Voc=-0.229%/C, Isc=14.4 A, STC=485.0 W, Area=2.1 m2.

Result: 12 panels max on 600 V (555.4 V); 17 panels for 8 kW (384 sq ft).

What Are the Published CEC Specifications for ReCreate DS-MERCURY-485TC?

Laboratory test ratings recorded for ReCreate DS-MERCURY-485TC (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for ReCreate DS-MERCURY-485TC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 485.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 456.6 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 42.85 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.4 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.51 V / 13.66 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.229 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.1% (2.1 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many ReCreate DS-MERCURY-485TC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (384 sq ft at 8 kW), and estimated Year-1 electric bill offset for ReCreate DS-MERCURY-485TC.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.3 kW 294 sq ft $1,577 $2,666
8 kW Class 17 8.24 kW 384 sq ft $2,062 $3,487
10 kW Class 21 10.19 kW 475 sq ft $2,550 $4,313

Which Sibling Wattage & Trim Variants Belong to This ReCreate Series?

Sibling wattage bins and frame colors grouped with ReCreate DS-MERCURY-485TC under ReCreate to prevent duplicate spec pages. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the ReCreate DS-MERCURY-485TC wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
ReCreate DS-MERCURY-475TC 475.0 W 446.9 W 42.51 V 35.19 V 22.62%
ReCreate DS-MERCURY-480TC 480.0 W 451.8 W 42.68 V 35.35 V 22.86%
ReCreate DS-MERCURY-485TC 485.0 W 456.6 W 42.85 V 35.51 V 23.1%

How Many ReCreate DS-MERCURY-485TC Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for ReCreate DS-MERCURY-485TC (beta_Voc -0.229%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=42.85V and beta_Voc=-0.229%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.27 V 12 panels 567.2 V 21 panels
-10 C (14 F) 46.28 V 12 panels 555.4 V 21 panels
0 C (32 F) 45.3 V 13 panels 588.9 V 22 panels
25 C (77 F STC) 42.85 V 14 panels 599.9 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to ReCreate DS-MERCURY-485TC?

Closest cross-brand CEC competitors to ReCreate DS-MERCURY-485TC matched near 485.0 W STC and 42.85 V Voc, led by Hanersun Energy Co Ltd HN18N-60HT485W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanersun Energy Co Ltd HN18N-60HT485W
Hanersun Energy Co Ltd
485.0 W Tie (0 W) 43.0 V 22.99% 94.9%
CSI Solar Co Ltd CS61-60TM-485H
CSI Solar Co Ltd
485.0 W Tie (0 W) 42.6 V 22.15% 94.7%
Auxin Solar AXN10M485B
Auxin Solar
485.0 W Tie (0 W) 43.98 V 22.56% 92.0%
Auxin Solar AXN10M485W
Auxin Solar
485.0 W Tie (0 W) 43.98 V 22.56% 91.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for ReCreate DS-MERCURY-485TC?

Evaluate ReCreate DS-MERCURY-485TC (485.0 W STC, 42.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), ReCreate DS-MERCURY-485TC reaches 47.27 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 384 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (384 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of ReCreate DS-MERCURY-485TC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

ReCreate DS-MERCURY-485TC 8 kW Residential Fit

Needs 17 modules (384 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Hanersun Energy Co Ltd HN18N-60HT485W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 456.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ReCreate DS-MERCURY-485TC by ReCreate grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

How many ReCreate DS-MERCURY-485TC panels fit on a 600 V winter solar string?

At -10 C (14 F), ReCreate DS-MERCURY-485TC cold Voc rises from 42.85 V to 46.28 V (beta_Voc -0.229%/C), capping a 600 V string at 12 panels (555.4 V).

How much roof area does an 8 kW array of ReCreate DS-MERCURY-485TC need?

An 8 kW DC system uses 17 ReCreate DS-MERCURY-485TC modules (8,245 W STC / 7,762 W PTC), covering roughly 384 sq ft and saving ~$2,062/yr at 18.54 c/kWh.

How does ReCreate DS-MERCURY-485TC compare against Hanersun Energy Co Ltd HN18N-60HT485W?

ReCreate DS-MERCURY-485TC outputs 485.0 W STC (42.85 V Voc, rank #4,730 of 21,677), while Hanersun Energy Co Ltd HN18N-60HT485W delivers 485.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.