ReCreate DS-MERCURY-470TC is a 470.0 W STC (442.1 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 22.38% efficiency, 42.35 V Voc at 25 C, and 45.74 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 470.0 W
- PTC Wattage
- 442.1 W
- Voc @ 25C
- 42.35 V
- Efficiency
- 22.38%
How Does ReCreate DS-MERCURY-470TC Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for ReCreate DS-MERCURY-470TC (Mono-c-Si) residential solar systems. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
Homeowners evaluating ReCreate DS-MERCURY-470TC need 13 panels for 6 kW or 18 panels (407 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (407 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.229%/C) pushes open-circuit voltage to 45.74 V at 14 F and 46.71 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does ReCreate DS-MERCURY-470TC Fall Across Listed CEC Models?
Comparison of ReCreate DS-MERCURY-470TC (470.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Dataset Percentiles Define ReCreate DS-MERCURY-470TC?
Relative ranking of ReCreate DS-MERCURY-470TC across nameplate watts, 94.1% PTC thermal ratio, and module aperture efficiency. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for ReCreate DS-MERCURY-470TC?
Summary of ReCreate DS-MERCURY-470TC output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 23.4% STC Output
470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.38% Aperture Efficiency
Power density 223.8 W/m2 (2.47 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.74 V at -10 C (594.6 V string) and 46.71 V at -20 C (12 max).
18 Panels = 8,460 W STC
Occupies 37.8 m2 (407 sq ft) producing 7,958 W PTC; NEC 690.8 OCPD floor is 22.09 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 42.35 * (1 + (-0.229/100) * (-10 - 25)) = 45.74 V | OCPD = 1.56 * 14.16 = 22.09 A
Inputs from CEC Modules.csv for ReCreate DS-MERCURY-470TC: Voc=42.35 V, beta_Voc=-0.229%/C, Isc=14.16 A, STC=470.0 W, Area=2.1 m2.
Result: 13 panels max on 600 V (594.6 V); 18 panels for 8 kW (407 sq ft).
What Are the Published CEC Specifications for ReCreate DS-MERCURY-470TC?
Complete CEC test sheet for ReCreate DS-MERCURY-470TC including Isc (14.16 A), Voc (42.35 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 470.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 442.1 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 42.35 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.16 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.03 V / 13.42 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.229 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.38% (2.1 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many ReCreate DS-MERCURY-470TC Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using ReCreate DS-MERCURY-470TC.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.11 kW | 294 sq ft | $1,529 | $2,586 |
| 8 kW Class | 18 | 8.46 kW | 407 sq ft | $2,117 | $3,580 |
| 10 kW Class | 22 | 10.34 kW | 497 sq ft | $2,588 | $4,376 |
How Many ReCreate DS-MERCURY-470TC Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for ReCreate DS-MERCURY-470TC (42.35 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.71 V | 12 panels | 560.5 V | 21 panels |
| -10 C (14 F) | 45.74 V | 13 panels | 594.6 V | 21 panels |
| 0 C (32 F) | 44.77 V | 13 panels | 582.0 V | 22 panels |
| 25 C (77 F STC) | 42.35 V | 14 panels | 592.9 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to ReCreate DS-MERCURY-470TC?
Four comparable CEC modules such as Aptos Solar Technology LLC DNA-120-BFN10-470W-DG (470.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-120-BFN10-470W-DG Aptos Solar Technology LLC |
470.0 W | Tie (0 W) | 42.38 V | 21.76% | 94.9% |
| CSI Solar Co Ltd CS61-60TM-470H CSI Solar Co Ltd |
470.0 W | Tie (0 W) | 42.0 V | 21.46% | 94.6% |
| Auxin Solar AXN10M470W Auxin Solar |
470.0 W | Tie (0 W) | 43.78 V | 21.86% | 92.0% |
| Elin Energy (Sirius PV) ELNSM60M-HC-475 Elin Energy (Sirius PV) |
475.0 W | +5.0 W | 41.82 V | 22.09% | 94.4% |
What Are the Design Limits and Best-Fit Uses for ReCreate DS-MERCURY-470TC?
Evaluate ReCreate DS-MERCURY-470TC (470.0 W STC, 42.35 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), ReCreate DS-MERCURY-470TC reaches 46.71 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 407 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (407 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of ReCreate DS-MERCURY-470TC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
ReCreate DS-MERCURY-470TC 8 kW Residential Fit
Needs 18 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,117/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-BFN10-470W-DG.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 442.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for ReCreate DS-MERCURY-470TC by ReCreate grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Why is ReCreate DS-MERCURY-470TC PTC wattage (442.1 W) lower than STC (470.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 442.1 W PTC (94.1% retention) across ReCreate DS-MERCURY-470TC's 2.1 m2 aperture.
Who should skip ReCreate DS-MERCURY-470TC on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 ReCreate DS-MERCURY-470TC panels (407 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-120-BFN10-470W-DG.
What is the 1,000 V commercial string limit for ReCreate DS-MERCURY-470TC?
On 1,000 V commercial inverters at -10 C (45.74 V cold Voc), ReCreate DS-MERCURY-470TC fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting ReCreate DS-MERCURY-470TC.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)