Elin Energy (Sirius PV) ELNSM60M-HC-475 is a 475.0 W STC (448.4 W PTC) Mono-c-Si solar module ranking #4,892 of 21,677 CEC listings (top 22.9%; higher than 77.1% of peers). It delivers 22.09% efficiency, 41.82 V Voc at 25 C, and 45.25 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 475.0 W
- PTC Wattage
- 448.4 W
- Voc @ 25C
- 41.82 V
- Efficiency
- 22.09%
How Does Elin Energy (Sirius PV) ELNSM60M-HC-475 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Elin Energy (Sirius PV) ELNSM60M-HC-475 (Mono-c-Si) residential solar systems.
Homeowners evaluating Elin Energy (Sirius PV) ELNSM60M-HC-475 need 13 panels for 6 kW or 17 panels (393 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 17 panels (393 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.234%/C) pushes open-circuit voltage to 45.25 V at 14 F and 46.22 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Elin Energy (Sirius PV) ELNSM60M-HC-475 Fall Across Listed CEC Models?
Comparison of Elin Energy (Sirius PV) ELNSM60M-HC-475 (475.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM60M-HC-475?
Relative ranking of Elin Energy (Sirius PV) ELNSM60M-HC-475 across nameplate watts, 94.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM60M-HC-475?
Summary of Elin Energy (Sirius PV) ELNSM60M-HC-475 output rank, 8 kW array size (17 panels), efficiency rating, and 600 V string limit.
Top 22.9% STC Output
475.0 W STC (+90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.09% Aperture Efficiency
Power density 220.9 W/m2 (2.18 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.25 V at -10 C (588.2 V string) and 46.22 V at -20 C (12 max).
17 Panels = 8,075 W STC
Occupies 36.5 m2 (393 sq ft) producing 7,623 W PTC; NEC 690.8 OCPD floor is 22.25 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.82 * (1 + (-0.234/100) * (-10 - 25)) = 45.25 V | OCPD = 1.56 * 14.26 = 22.25 A
Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM60M-HC-475: Voc=41.82 V, beta_Voc=-0.234%/C, Isc=14.26 A, STC=475.0 W, Area=2.15 m2.
Result: 13 panels max on 600 V (588.2 V); 17 panels for 8 kW (393 sq ft).
What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM60M-HC-475?
Complete CEC test sheet for Elin Energy (Sirius PV) ELNSM60M-HC-475 including Isc (14.26 A), Voc (41.82 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 475.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 448.4 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.82 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.26 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.78 V / 13.63 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.234 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.09% (2.15 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Elin Energy (Sirius PV) ELNSM60M-HC-475 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Elin Energy (Sirius PV) ELNSM60M-HC-475.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.17 kW | 301 sq ft | $1,544 | $2,611 |
| 8 kW Class | 17 | 8.07 kW | 393 sq ft | $2,020 | $3,415 |
| 10 kW Class | 22 | 10.45 kW | 509 sq ft | $2,616 | $4,423 |
How Many Elin Energy (Sirius PV) ELNSM60M-HC-475 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Elin Energy (Sirius PV) ELNSM60M-HC-475 (41.82 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.22 V | 12 panels | 554.6 V | 21 panels |
| -10 C (14 F) | 45.25 V | 13 panels | 588.2 V | 22 panels |
| 0 C (32 F) | 44.27 V | 13 panels | 575.5 V | 22 panels |
| 25 C (77 F STC) | 41.82 V | 14 panels | 585.5 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM60M-HC-475?
Four comparable CEC modules such as CSI Solar Co Ltd CS61-60TM-470H (470.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS61-60TM-470H CSI Solar Co Ltd |
470.0 W | -5.0 W | 42.0 V | 21.46% | 94.6% |
| Aptos Solar Technology LLC DNA-120-BFN10-470W-DG Aptos Solar Technology LLC |
470.0 W | -5.0 W | 42.38 V | 21.76% | 94.9% |
| Aptos Solar Technology LLC DNA-120-BFN10-480W-DG Aptos Solar Technology LLC |
480.0 W | +5.0 W | 42.61 V | 22.22% | 94.9% |
| Auxin Solar AXN10M470W Auxin Solar |
470.0 W | -5.0 W | 43.78 V | 21.86% | 92.0% |
What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM60M-HC-475?
Evaluate Elin Energy (Sirius PV) ELNSM60M-HC-475 (475.0 W STC, 41.82 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM60M-HC-475 reaches 46.22 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 393 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (393 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM60M-HC-475 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Elin Energy (Sirius PV) ELNSM60M-HC-475 8 kW Residential Fit
Needs 17 modules (393 sq ft) with a 25 A string OCPD, offsetting ~$2,020/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS61-60TM-470H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 448.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Elin Energy (Sirius PV) ELNSM60M-HC-475 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Elin Energy (Sirius PV) ELNSM60M-HC-475 PTC wattage (448.4 W) lower than STC (475.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 448.4 W PTC (94.4% retention) across Elin Energy (Sirius PV) ELNSM60M-HC-475's 2.15 m2 aperture.
Who should skip Elin Energy (Sirius PV) ELNSM60M-HC-475 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 Elin Energy (Sirius PV) ELNSM60M-HC-475 panels (393 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS61-60TM-470H.
What is the 1,000 V commercial string limit for Elin Energy (Sirius PV) ELNSM60M-HC-475?
On 1,000 V commercial inverters at -10 C (45.25 V cold Voc), Elin Energy (Sirius PV) ELNSM60M-HC-475 fits up to 22 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)