Perlight Solar PLM-290P-72 is a 290.0 W STC (258.4 W PTC) Multi-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.87% efficiency, 45.14 V Voc at 25 C, and 50.2 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 258.4 W
- Voc @ 25C
- 45.14 V
- Efficiency
- 14.87%
How Does Perlight Solar PLM-290P-72 Compare Against Peer CEC Listings?
How Perlight Solar Perlight Solar PLM-290P-72 handles rooftop heat (258.4 W PTC), 8 kW sizing, and cold winter string voltage.
Perlight Solar builds the Perlight Solar PLM-290P-72 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 148.7 W/m2 (5.04 percentage points below 19.91% CEC median). Compared against AXITEC AC-290M/156-72S (290.0 W), this model holds typical 89.1% PTC-to-STC thermal output (258.4 W real-world rating). Mid-range 45.14 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.56 A overcurrent floor served by a 15 A breaker.
Where Does Perlight Solar PLM-290P-72 Fall Across Listed CEC Models?
Where Perlight Solar PLM-290P-72 (290.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Perlight Solar PLM-290P-72?
Percentile placement of Perlight Solar PLM-290P-72 across power density (148.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Perlight Solar PLM-290P-72?
Four critical engineering numbers homeowners and solar installers check first when reviewing Perlight Solar PLM-290P-72 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.87% Aperture Efficiency
Power density 148.7 W/m2 (5.04 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.2 V at -10 C (552.2 V string) and 51.64 V at -20 C (11 max).
28 Panels = 8,120 W STC
Occupies 54.6 m2 (588 sq ft) producing 7,235 W PTC; NEC 690.8 OCPD floor is 13.56 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.14 * (1 + (-0.32/100) * (-10 - 25)) = 50.2 V | OCPD = 1.56 * 8.69 = 13.56 A
Inputs from CEC Modules.csv for Perlight Solar PLM-290P-72: Voc=45.14 V, beta_Voc=-0.32%/C, Isc=8.69 A, STC=290.0 W, Area=1.95 m2.
Result: 11 panels max on 600 V (552.2 V); 28 panels for 8 kW (588 sq ft).
What Are the Published CEC Specifications for Perlight Solar PLM-290P-72?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Perlight Solar PLM-290P-72.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 258.4 W (89.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.14 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.27 V / 8.23 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.32 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.87% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Perlight Solar PLM-290P-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Perlight Solar PLM-290P-72 (290.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 441 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 588 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 735 sq ft | $2,540 | $4,296 |
How Many Perlight Solar PLM-290P-72 Modules Fit in a Cold-Weather String?
Maximum series module counts for Perlight Solar PLM-290P-72 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.64 V | 11 panels | 568.0 V | 19 panels |
| -10 C (14 F) | 50.2 V | 11 panels | 552.2 V | 19 panels |
| 0 C (32 F) | 48.75 V | 12 panels | 585.0 V | 20 panels |
| 25 C (77 F STC) | 45.14 V | 13 panels | 586.8 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Perlight Solar PLM-290P-72?
Alternative CEC solar modules from competing brands near Perlight Solar PLM-290P-72 (290.0 W), including AXITEC AC-290M/156-72S. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-290M/156-72S AXITEC |
290.0 W | Tie (0 W) | 44.98 V | 14.95% | 90.6% |
| Gintung Energy GTEC-290G6S Gintung Energy |
290.0 W | Tie (0 W) | 44.84 V | 14.83% | 89.7% |
| Gintung Energy GTEC-290G6M Gintung Energy |
290.0 W | Tie (0 W) | 44.61 V | 14.83% | 89.6% |
| Centrosolar America DM72 290 Centrosolar America |
290.0 W | Tie (0 W) | 44.4 V | 14.92% | 90.6% |
What Are the Design Limits and Best-Fit Uses for Perlight Solar PLM-290P-72?
Evaluate Perlight Solar PLM-290P-72 (290.0 W STC, 45.14 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Perlight Solar PLM-290P-72 reaches 51.64 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 588 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (588 sq ft).
- 2026 tax credit baseline: cash residential installs of Perlight Solar PLM-290P-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Perlight Solar PLM-290P-72 8 kW Residential Fit
Needs 28 modules (588 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-290M/156-72S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 258.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Perlight Solar PLM-290P-72 by Perlight Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Perlight Solar PLM-290P-72?
Multiplying Perlight Solar PLM-290P-72's 8.69 A short-circuit current by 1.56 equals 13.56 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Perlight Solar PLM-290P-72 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.2 V cold Voc at 14 F and handles 8.69 A Isc; string inverters cap Perlight Solar PLM-290P-72 at 11 panels on 600 V.
Is Perlight Solar PLM-290P-72 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Perlight Solar PLM-290P-72 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)