Perlight Solar PLM-235P-60 is a 235.0 W STC (210.9 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.36% efficiency, 37.25 V Voc at 25 C, and 42.6 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 235.0 W
- PTC Wattage
- 210.9 W
- Voc @ 25C
- 37.25 V
- Efficiency
- 14.36%
How Does Perlight Solar PLM-235P-60 Compare Against Peer CEC Listings?
How Perlight Solar Perlight Solar PLM-235P-60 handles rooftop heat (210.9 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Perlight Solar PLM-235P-60 exhibits 8.28 A short-circuit current, requiring a 12.92 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,368 of 21,677 (43.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 57.3 m2 for an 8 kW system (43 panels for 10 kW). Lower 37.25 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Perlight Solar PLM-235P-60 Fall Across Listed CEC Models?
Where Perlight Solar PLM-235P-60 (235.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Perlight Solar PLM-235P-60?
Percentile placement of Perlight Solar PLM-235P-60 across power density (143.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Perlight Solar PLM-235P-60?
Four critical engineering numbers homeowners and solar installers check first when reviewing Perlight Solar PLM-235P-60 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
235.0 W STC · Higher Than 5.4%
235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.36% Aperture Efficiency
Power density 143.6 W/m2 (5.55 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.6 V at -10 C (596.4 V string) and 44.12 V at -20 C (13 max).
35 Panels = 8,225 W STC
Occupies 57.3 m2 (617 sq ft) producing 7,382 W PTC; NEC 690.8 OCPD floor is 12.92 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.25 * (1 + (-0.41/100) * (-10 - 25)) = 42.6 V | OCPD = 1.56 * 8.28 = 12.92 A
Inputs from CEC Modules.csv for Perlight Solar PLM-235P-60: Voc=37.25 V, beta_Voc=-0.41%/C, Isc=8.28 A, STC=235.0 W, Area=1.637 m2.
Result: 14 panels max on 600 V (596.4 V); 35 panels for 8 kW (617 sq ft).
What Are the Published CEC Specifications for Perlight Solar PLM-235P-60?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Perlight Solar PLM-235P-60.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 210.9 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.3 V / 7.75 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.41 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.36% (1.637 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Perlight Solar PLM-235P-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Perlight Solar PLM-235P-60 (235.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 26 | 6.11 kW | 458 sq ft | $1,529 | $2,586 |
| 8 kW Class | 35 | 8.22 kW | 617 sq ft | $2,057 | $3,479 |
| 10 kW Class | 43 | 10.11 kW | 758 sq ft | $2,530 | $4,279 |
How Many Perlight Solar PLM-235P-60 Modules Fit in a Cold-Weather String?
Maximum series module counts for Perlight Solar PLM-235P-60 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.12 V | 13 panels | 573.6 V | 22 panels |
| -10 C (14 F) | 42.6 V | 14 panels | 596.4 V | 23 panels |
| 0 C (32 F) | 41.07 V | 14 panels | 575.0 V | 24 panels |
| 25 C (77 F STC) | 37.25 V | 16 panels | 596.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Perlight Solar PLM-235P-60?
Alternative CEC solar modules from competing brands near Perlight Solar PLM-235P-60 (235.0 W), including Gintech Energy GTE 235M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintech Energy GTE 235M Gintech Energy |
235.0 W | Tie (0 W) | 37.32 V | 13.97% | 89.5% |
| APOS Energy AS235 APOS Energy |
235.0 W | Tie (0 W) | 37.34 V | 14.17% | 89.7% |
| AXITEC AC-235P/156-60S AXITEC |
235.0 W | Tie (0 W) | 37.16 V | 14.48% | 90.0% |
| Advance Power API-M235 Advance Power |
235.0 W | Tie (0 W) | 37.5 V | 14.35% | 89.3% |
What Are the Design Limits and Best-Fit Uses for Perlight Solar PLM-235P-60?
Evaluate Perlight Solar PLM-235P-60 (235.0 W STC, 37.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Perlight Solar PLM-235P-60 reaches 44.12 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 617 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (617 sq ft).
- 2026 tax credit baseline: cash residential installs of Perlight Solar PLM-235P-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Perlight Solar PLM-235P-60 8 kW Residential Fit
Needs 35 modules (617 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Gintech Energy GTE 235M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 210.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Perlight Solar PLM-235P-60 by Perlight Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Perlight Solar PLM-235P-60 PTC wattage (210.9 W) lower than STC (235.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 210.9 W PTC (89.7% retention) across Perlight Solar PLM-235P-60's 1.637 m2 aperture.
Who should skip Perlight Solar PLM-235P-60 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 Perlight Solar PLM-235P-60 panels (617 sq ft) leave unusable roof gaps vs. Gintech Energy GTE 235M.
What is the 1,000 V commercial string limit for Perlight Solar PLM-235P-60?
On 1,000 V commercial inverters at -10 C (42.6 V cold Voc), Perlight Solar PLM-235P-60 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Perlight Solar PLM-235P-60.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)