Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SM400M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SM400M is a 400.0 W STC (371.5 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.62% efficiency, 50.39 V Voc at 25 C, and 55.17 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
400.0 W
PTC Wattage
371.5 W
Voc @ 25C
50.39 V
Efficiency
20.62%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SM400M Compare Against Peer CEC Listings?

Engineering position of PEIMAR SM400M (400.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-400-H across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, PEIMAR SM400M pairs strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677) with 50.39 V nominal Voc. An 8 kW residential build (8,000 W DC, 7,430 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Boviet Solar Technology Co Ltd BVM6612M-400-H offers a 400.0 W alternative.

Where Does PEIMAR SM400M Fall Across Listed CEC Models?

Plots PEIMAR SM400M at 400.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SM400M (400.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SM400M: 400.0 W

What Dataset Percentiles Define PEIMAR SM400M?

Benchmarks PEIMAR SM400M on STC wattage, thermal PTC/STC retention, and 20.62 aperture conversion efficiency against CEC peers.

PEIMAR SM400M Engineering BenchmarksPercentile comparison of PEIMAR SM400M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage400.0 WPTC/STC Retention92.9%Module Efficiency20.62%

What Do the Dataset Ranks Show for PEIMAR SM400M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR SM400M by PEIMAR.

Rank #9,407 / 21,677

Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,995

20.62% Aperture Efficiency

Power density 206.2 W/m2 (0.71 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.17 V at -10 C (551.7 V string) and 56.54 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,000 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,430 W PTC; NEC 690.8 OCPD floor is 16.01 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.39 * (1 + (-0.271/100) * (-10 - 25)) = 55.17 V | OCPD = 1.56 * 10.26 = 16.01 A

Inputs from CEC Modules.csv for PEIMAR SM400M: Voc=50.39 V, beta_Voc=-0.271%/C, Isc=10.26 A, STC=400.0 W, Area=1.94 m2.

Result: 10 panels max on 600 V (551.7 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for PEIMAR SM400M?

Laboratory test ratings recorded for PEIMAR SM400M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SM400M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 400.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 371.5 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.39 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.26 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.3 V / 9.69 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.271 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.62% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SM400M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (418 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR SM400M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.0 kW 313 sq ft $1,502 $2,539
8 kW Class 20 8.0 kW 418 sq ft $2,002 $3,386
10 kW Class 25 10.0 kW 522 sq ft $2,503 $4,232

How Many PEIMAR SM400M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PEIMAR SM400M (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=50.39V and beta_Voc=-0.271%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.54 V 10 panels 565.4 V 17 panels
-10 C (14 F) 55.17 V 10 panels 551.7 V 18 panels
0 C (32 F) 53.8 V 11 panels 591.8 V 18 panels
25 C (77 F STC) 50.39 V 11 panels 554.3 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SM400M?

Closest cross-brand CEC competitors to PEIMAR SM400M matched near 400.0 W STC and 50.39 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-400-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-W5-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-405L-H
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 20.35% 93.3%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 19.95% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SM400M?

Evaluate PEIMAR SM400M (400.0 W STC, 50.39 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SM400M reaches 56.54 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SM400M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SM400M 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 371.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SM400M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

What fuse or breaker size does NEC 690.8 require for PEIMAR SM400M?

Multiplying PEIMAR SM400M's 10.26 A short-circuit current by 1.56 equals 16.01 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SM400M before finalizing component orders.

Can PEIMAR SM400M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.17 V cold Voc at 14 F and handles 10.26 A Isc; string inverters cap PEIMAR SM400M at 10 panels on 600 V.

Is PEIMAR SM400M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SM400M rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.