Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SM385M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SM385M is a 385.0 W STC (357.2 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.85% efficiency, 49.66 V Voc at 25 C, and 54.37 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
385.0 W
PTC Wattage
357.2 W
Voc @ 25C
49.66 V
Efficiency
19.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SM385M Compare Against Peer CEC Listings?

Engineering position of PEIMAR SM385M (385.0 W STC) vs. EMMVEE Photovoltaic Power Private Limited E385M72 across 5,889 CEC Mono-c-Si solar modules.

Ranking #10,723 across 21,677 CEC solar panels (at all-CEC median; higher than 49.1% of peers), PEIMAR SM385M operates as a compact residential or specialty off-grid module sitting 25.0 W below the 410.0 W Mono-c-Si median. Higher 49.66 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677), 21 panels occupy 439 sq ft and offset roughly $2,025/yr at average US rates (or $3,424/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does PEIMAR SM385M Fall Across Listed CEC Models?

Plots PEIMAR SM385M at 385.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SM385M (385.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SM385M: 385.0 W

What Dataset Percentiles Define PEIMAR SM385M?

Benchmarks PEIMAR SM385M on STC wattage, thermal PTC/STC retention, and 19.85 aperture conversion efficiency against CEC peers.

PEIMAR SM385M Engineering BenchmarksPercentile comparison of PEIMAR SM385M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage385.0 WPTC/STC Retention92.8%Module Efficiency19.85%

What Do the Dataset Ranks Show for PEIMAR SM385M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR SM385M by PEIMAR.

Rank #10,723 / 21,677

385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,028

19.85% Aperture Efficiency

Power density 198.5 W/m2 (0.06 percentage points below 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.37 V at -10 C (598.1 V string) and 55.72 V at -20 C (10 max).

8 kW Reference Array

21 Panels = 8,085 W STC

Occupies 40.7 m2 (439 sq ft) producing 7,501 W PTC; NEC 690.8 OCPD floor is 15.63 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.66 * (1 + (-0.271/100) * (-10 - 25)) = 54.37 V | OCPD = 1.56 * 10.02 = 15.63 A

Inputs from CEC Modules.csv for PEIMAR SM385M: Voc=49.66 V, beta_Voc=-0.271%/C, Isc=10.02 A, STC=385.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (598.1 V); 21 panels for 8 kW (439 sq ft).

What Are the Published CEC Specifications for PEIMAR SM385M?

Laboratory test ratings recorded for PEIMAR SM385M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SM385M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 385.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 357.2 W (92.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.66 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.02 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.7 V / 9.46 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.271 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.85% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SM385M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (439 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR SM385M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.16 kW 334 sq ft $1,542 $2,607
8 kW Class 21 8.09 kW 439 sq ft $2,025 $3,424
10 kW Class 26 10.01 kW 543 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Sibling wattage bins and frame colors grouped with PEIMAR SM385M under PEIMAR to prevent duplicate spec pages. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the PEIMAR SM385M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SM375M 375.0 W 347.7 W 49.17 V 40.3 V 19.33%
PEIMAR SM380M 380.0 W 352.4 W 49.41 V 40.5 V 19.59%
PEIMAR SM385M 385.0 W 357.2 W 49.66 V 40.7 V 19.85%
PEIMAR SM390M 390.0 W 362.0 W 49.9 V 40.9 V 20.1%
PEIMAR SM395M 395.0 W 366.7 W 50.14 V 41.1 V 20.36%

How Many PEIMAR SM385M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PEIMAR SM385M (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.66V and beta_Voc=-0.271%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.72 V 10 panels 557.2 V 17 panels
-10 C (14 F) 54.37 V 11 panels 598.1 V 18 panels
0 C (32 F) 53.02 V 11 panels 583.2 V 18 panels
25 C (77 F STC) 49.66 V 12 panels 595.9 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SM385M?

Closest cross-brand CEC competitors to PEIMAR SM385M matched near 385.0 W STC and 49.66 V Voc, led by EMMVEE Photovoltaic Power Private Limited E385M72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
EMMVEE Photovoltaic Power Private Limited E385M72
EMMVEE Photovoltaic Power Private Limited
385.0 W Tie (0 W) 48.9 V 19.32% 92.0%
Boviet Solar Technology Co Ltd BVM6612M-385-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-W5-385-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-385L-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 19.35% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SM385M?

Evaluate PEIMAR SM385M (385.0 W STC, 49.66 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SM385M reaches 55.72 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (439 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SM385M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SM385M 8 kW Residential Fit

Needs 21 modules (439 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E385M72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 357.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SM385M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

How many PEIMAR SM385M panels fit on a 600 V winter solar string?

At -10 C (14 F), PEIMAR SM385M cold Voc rises from 49.66 V to 54.37 V (beta_Voc -0.271%/C), capping a 600 V string at 11 panels (598.1 V).

How much roof area does an 8 kW array of PEIMAR SM385M need?

An 8 kW DC system uses 21 PEIMAR SM385M modules (8,085 W STC / 7,501 W PTC), covering roughly 439 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

How does PEIMAR SM385M compare against EMMVEE Photovoltaic Power Private Limited E385M72?

PEIMAR SM385M outputs 385.0 W STC (49.66 V Voc, rank #10,723 of 21,677), while EMMVEE Photovoltaic Power Private Limited E385M72 delivers 385.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls